Features

  • Universal AC input / full range
  • Built-in active PFC function, PF>0.93
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in cooling fan speed control
  • Built-in constant current limiting circuit
  • Built-in fan speed control
  • Remote ON-OFF control(Optional)
  • LED indicator for power on
  • 100% full load burn-in test
  • Fixed switching frequency at PFC:67KHz PWM:134KHz
  • 3 years warranty

SPECIFICATION

MODEL| SP-200-3.3| SP-200-5| SP-200-7.5| SP-200-12| SP-200-13.5| SP-200-15| SP-200-24| SP-200-27| SP-200-48
---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 7.5V| 12V| 13.5V| 15V| 24V| 27V| 48V
RATED CURRENT| 40A| 40A| 26.7A| 16.7A| 14.9A| 13.4A| 8.4A| 7.5A| 4.2A
CURRENT RANGE| 0 ~ 40A| 0 ~ 40A| 0 ~ 26.7A| 0 ~ 16.7A| 0 ~ 14.9A| 0 ~ 13.4A| 0 ~ 8.4A| 0 ~ 7.5A| 0 ~ 4.2A
RATED POWER| 132W| 200W| 200.2W| 200.4W| 201.1W| 201W| 201.6W| 202.5W| 201.6W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| 3.14 ~ 3.63V| 4.75 ~ 5.5V| 7.13 ~ 8.25V| 11.4 ~ 13.2V| 12.8 ~ 14.9V| 14.3 ~ 16.5V| 22.8 ~ 26.4V| 25.7 ~ 29.7V| 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 600ms, 40ms at full load
HOLD UP TIME (Typ.)| 20ms at full load
INPUT| VOLTAGE RANGE| 85 ~ 264VAC       120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.93/230VAC       PF>0.97/115VAC at full load
EFFICIENCY (Typ.)| 69%| 76%| 78.5%| 84%| 84%| 84%| 85%| 85%| 85%
AC CURRENT (Typ.)| 3.5A/115VAC      1.7A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.63 ~ 4.46V| 5.5 ~ 6.75V| 8.25 ~ 10.13V| 13.2 ~ 16.2V| 14.85 ~ 18.2V| 16.5 ~ 20.25V| 26.4 ~ 32.4V| 29.7 ~ 36.45V| 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| REMOTE CONTROL(OPTION)| CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF
ENVIRONMENT| WORKING TEMP.| -10 ~ +60℃ (Refer to output load derating curve)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & **EMC
(Note 4)| SAFETY STANDARDS| UL60950-1, CCC GB4943 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/70% RH
EMC EMISSION| Compliance to EN55032 (CISPR32) Class B,EN61000-3-2,-3
EMC IMMUNITY| Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
OTHERS| MTBF| 183.8K hrs min.    MIL-HDBK-217F (25℃)
DIMENSION| 1999950mm (LWH)
PACKING| 0.85Kg; 20pcs/17.9Kg/1.21CUFT
NOTE**|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Terminal Pin No. Assignment
Mechanical Specification

Pin No. Assignment Pin No. Assignment
1 AC/L 4,5 DC OUTPUT -V
2 AC/N 6,7 DC OUTPUT +V
3 FG  

Remote ON/OFF(CN1):JST S2B-XH or equivalent(optional)
Mechanical Specification

Pin No. Assignment Mating Housing Terminal
1 RC+ JST XHP or equivalent JST SXH-001T-P0.6 or equivalent
2 RC-

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Output Derating VS Input Voltage

Output Derating VS Input Voltage