GRIVEN AL5003 DUNE MK3 Recessed Spotlight User Manual

June 1, 2024
GRIVEN

GRIVEN AL5003 DUNE MK3 Recessed Spotlight

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-product-
image

Product Information

Specifications:

  • Model: Dune MK3
  • Model Number: AL5003
  • Weight: 7.9 Kg (17.40 Lbs)
  • Housing: AISI 316L stainless steel in ABS formwork
  • IK Rating: IK10
  • IP Rating: IP
  • Ambient Temperature: 100-240 VAC 50/60Hz
  • Power Supply: 60A @230VAC
  • Inrush Current: 27 W 0,16A@230VAC
  • Thermal Protection: Electronic I
  • Cable: 1 m USITT DMX-512 RDM
  • Control System: 4/5/6 (RGBW 4000K), 2/3 (DW), 1 (Monochromatic)
  • Channels: 20 High output LEDS additive synthesis
  • Color Range: Millions of colors spot, narrow, medium, wide, extra wide, elliptical, elliptical wide
  • Optics: Ottiche
  • Dimensions: 306mm x 345mm x 365mm

Product Usage Instructions

  1. Safety Precautions:
  2. Do not stare at the operating light source.
  3. Use an adequate magneto thermic switch along the power supply line.
  4. Never leave cables and connectors unconnected or unprotected for long periods.
  5. Disconnect power before installing or servicing to avoid electrical shock.
  6. Do not handle the unit with wet hands or in wet environments.
  7. Maintenance and Installation:
  8. Apply to qualified staff for any maintenance service not described in this instructions manual.
  9. Ensure to use cables and connectors with proper section and length based on power consumption.
  10. Fix the projector securely using appropriate supports that can bear its weight.
  11. Usage:
  12. Avoid prolonged staring at the LED source by placing the fixture in a proper position.
  13. Fixing and connecting operations must be carried out by qualified personnel only.

FAQ:

  • Q: How many channels does the Dune MK3 support?
    A: The Dune MK3 supports 20 High output LEDS additive synthesis channels.

  • Q: What is the recommended ambient temperature for the product?
    A: The recommended ambient temperature range is 100-240 VAC at 50/60Hz.

  • Q: How should I fix the projector securely?
    A: Fix the projector using screws, hooks, or other adequate supports that can bear its weight.

Dune MK3
AL5003

User Manual
Rev. 2.00
Date: 19/10/2021

Weight 7,9 Kg (17.40 Lbs)
Housing AISI 316L stainless steel in ABS formwork
IK rating IK10
IP rating IP68 (-1.5M)
Ambient temp. -40°C to 50°C ( -40°F to122°F)
Power supply 100-240 VAC 50/60Hz
Inrush current 60A @230VAC
Power 27 W
Nominal current 0,16A@230VAC
Thermal protection Electronic
Electrical class I
Cable 1 m
Control USITT DMX-512 RDM
Channels 4/5/6 (RGBW 4000K), 2/3 (DW), 1 (Monochromatic)
Color range 20 High output LEDS additive syntesis: RGBW-millions of

colours
Optics| spot, narrow, medium, wide, extra wide, elliptical, elliptical wide

Dimensions

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(2\)

Important notices

  • This product must be installed in accordance with applicable national and local electrical and construction codes by a person familiar with the construction and operation of the product and the hazards involved. Failure to comply with the following installation instructions may result in death or serious injury.
  • Do not stare at the operating light source.
  • The fixture might be damaged by excess voltage. The installation of an overvoltage protection device on the electrical system (SPD) is recommended for reduce the risk of damage.
  • The use of an adequate magnetothermic switch along the power supply line is recommended.
  • Connect the fixtures to each other only when disconnected from mains.
  • Never leave cables and connectors unconnected or unprotected for long periods.
  • Disconnect power before installing or servicing to avoid electrical shock.
  • Disconnect power before any connection operation.
  • Check voltage and frequency before powering the fixture. Do not exceed fixture specified voltage.
  • Do not handle the unit with wet hands or in wet environments.
  • Apply to qualified staff for any maintenance service not described in this instructions manual.
  • Do not exceed the maximum quantity of fixtures per line in order to avoid power surges.
  • Before powering the unit, ensure to use cables and connectors with proper section and length, according to its power consumption.
  • Fix the projector by using screws, hooks or other adequate supports that can bear its weight.

CAUTION: Prolonged staring at the LED source should be avoided by placing the fixture in a proper position.
WARNING ! Fixing and connecting operations must mandatorily be carried out by qualified personnel only !
WARNING ! Make sure that power supply is off before connecting or disconnecting fixtures !

Installation

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(5\)

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(6\)

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(7\)

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(8\)

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(9\) Note: Formwork Installation

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(10\)

Connecting

The power and signal connections can be carried out by using the connection kit enclosed in the box. Follow the instructions provided along with the connection kit.
GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(11\)

Beam aimig

Beam angle can be varied from -9° to +9°. Remove all the screws from the flange and move the LED surface by pushing it with your fingers. Once achieved the aiming required, it is recommended to power up the opened fixture for few minutes in order to let escape the internal moisture, then close it. This procedure is highly recommended every time the opening of the fixture in needed .GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(12\)

Typical system diagram:

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(13\)

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(14\)

WARNING ! in this mode, no other DMX control device must be present along the line.
WARNING ! Use a DMX repeater on each 32nd fixture of the chain or in case the cable length exceeds 300m ( 1000 ft.). Install a data terminator ( 120Ω) between Data+ and Data- on the DMX out cable of the last unit.

For further details consult the configuration schemes available on our website.

Setup

-The fixture must be configured only by using AL1321 IR remote control ( sold separately ) and from any DMX-RDM compatible controller.
GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(15\) GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig-
\(16\)

  • WARNING ! in this mode no other DMX control device must be present along the line.

DMX charts

RDM functions:

  • When operating in DMX mode the fixture can accept the following RDM commands:
    • discovery: Upon request of the RDM controller, the fixture signals its own presence (the RDM controller will display the fixture on a list).
    • DMX address reading and setting.
    • Channels number reading and setting.
  • On / Off identification: This command is used to identify the fixture you want to get access to (the identification happens by switching on all the LEDs at full intensity).
  • Manufacturer: it displays the name of the manufacturer (Griven).
  • Model description: it displays the fixture’s model.
  • Software version description: it displays the current version of the firmware.
  • Temperature: it displays the LEDs operating temperature value.

RGBW

Mode Modo| Channel Canale| Function Funzione| Value Valore
---|---|---|---
4| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% White| 0-255
5| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% White| 0-255
5| Dimmer 100%| 0-015
Dimmer 100% – 0%| 016-150
Dimmer 0%| 151-160
0-100% Strobo| 161-255
6| 1| 0-100% Red| 0-255
2| 0-100% Green| 0-255
3| 0-100% Blue| 0-255
4| 0-100% White| 0-255
5| 0% Dimmer| 0-5
100-0% Dimmer| 6-250
100% Dimmer| 251-255
6| No Strobo| 0-5
0-100% Strobo| 6-250
100% Strobo| 251-255

Note:
W and DW versions: in absence of DMX signal the LEDs will remain on. RGBW version: in absence of DMX signal the LEDs will remain off.

DW (Dynamic White)

Mode Modo| Channel Canale| Function Funzione| Value Valore
---|---|---|---
2| 1| 100%warm 0%cold| 0-3
100%warm-

0%→100% cold

| 4-122
100% warm 100% cold| 123-132
100%→0% warm 100% cold| 133-251
0% warm

100% cold

| 251-255
2| Dimmer 100%| 0-015
Dimmer 100% – 0%| 016-150
Dimmer 0%| 151-160
Strobo 0% – 100%| 161-255
3| 1| 0%→100% warm| 0-255
2| 0%→100% cold| 0-255
3| Dimmer 100%| 0-15
Dimmer 100% – 0%| 016-150
Dimmer 0%| 151-160
Strobo 0% – 100%| 161-255

Monochromatic version

Channel Canale Function Funzione Value Valore
1 Dimmer 100% 0-015
Dimmer 100% – 0% 016-150
Dimmer 0% 151-160
Strobo 0% – 100% 161-255

Polar Edition features ( only for PE fixtures )

  • The POLAR Edition is fitted with a thermal glass which is particularly useful for outdoor applications.
  • In fact, by warming up, the glass melts ice and snow which might interfere with the projection.
  • When the projector is on, if required by the weather conditions, the glass is automatically warmed up.

If the projection is to be started at a definite time, take care to defrost the glass in advance so that the LEDs can be lit at the time required.

GRIVEN-AL5003-DUNE-MK3-Recessed-Spotlight-fig- \(17\)

At very low temperatures (below -20° C), It is recommended to let the fixture always powered and to switch on the LEDs when needed.

Griven S.r.l. – Via Bulgaria, 16 46042 Castel Goffredo Mantova – Italy
Tel. +39.0376.779483
E-mail: sales@griven.com
Web: www.griven.com
© Copyright Griven 2017 – Griven reserves the right to make changes to this product and related instructions at any time without prior notice and such changes shall be effective immediatly.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GRIVEN User Manuals

Related Manuals