SEALEY LP100.V7 Propane Space Heater Instruction Manual
- June 1, 2024
- SEALEY
Table of Contents
LP100.V7 Propane Space Heater
Instruction Manual PROPANE SPACE HEATER 61,000-102,000BTU/HR
(18-30KW) SPACE WARMER®
MODEL NO: LP100.V7
LP100.V7 Propane Space Heater
Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND
WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP
THESE INSTRUCTIONS SAFE FOR FUTURE USE. ![SEALEY LP100.V7 Propane Space Heater
- icon](https://manuals.plus/wp-content/uploads/2024/05/SEALEY-LP100.V7 -Propane-Space-Heater-icon.png)
This product is not suitable for primary heating purposes.
SAFETY
1.1. ELECTRICAL SAFETY
‰ WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe
before using. Inspect power supply leads, plugs and all electrical connections
for wear and damage. Sealey recommend that an RCD (Residual Current Device) is
used with all electrical products. If used in the course of business duties,
it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information
is read and understood.
Ensure that the insulation on all cables and on the appliance is safe before
connecting it to the power supply.
Regularly inspect power supply cables and plugs for wear or damage and check
all connections to ensure that they are secure.
Ensure that the voltage rating on the appliance suits the power supply to be
used and that the plug is fitted with the correct fuse – see fuse rating in
these instructions.
8 DO NOT pull or carry the appliance by the power cable.
8 DO NOT pull the plug from the socket by the cable.
8 DO NOT use worn or damaged cables, plugs or connectors. Ensure that any
faulty item is repaired or replaced immediately by a qualified electrician.
This product is fitted with a BS1363/A 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply off
and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 3 pin plug. If in doubt contact a
qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that
the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2. GENERAL SAFETY
‰ WARNING! failure to comply with the precautions and instructions
provided with the heater can result in death, serious bodily injury and
property loss or damage from the hazards of fire, explosion, burning,
asphyxiation, carbon monoxide poisoning and/or electric shock.
‰ WARNING! Only persons who can understand and follow these instructions
should use or service this heater. Not for home or recreational vehicle use.
‰ WARNING! NOT to be used for the heating of habitable areas of domestic
premises: for use in public buildings, refer to national regulations.
Only use outdoors or in well ventilated surroundings in a well ventilated area
away from combustible materials.
For every kW it is necessary to have a permanent ventilation of 25cm x 25cm.
Never direct the hot air flow towards the cylinder.
Never use the heater without its cover.
DO NOT exceed 100W/m³ of free room. The minimum volume of the room must be
larger than 100m³.
DO NOT use in cellars, basements or in any room below ground level.
DO NOT obstruct the inlet or outlet sections of the heater.
‰ WARNING! DO NOT cover the heater.
‰ WARNING! some parts of the heater can become very hot and cause burns.
Particular attention has to be given to where children and vulnerable people
are present.
The heater must be placed where there is no risk of fire, the hot air outlet
must be at least 3m from any flammable wall or ceiling and must never be
directed towards the gas bottle.
Turn off the gas supply at the cylinder valve after use.
Only use the propane gas pressure regulator and hose assembly supplied with
the heater without alteration.
Gas cylinder must be used and kept in accordance with current regulations.
The gas bottle must be replaced according to safety rules and away from
sources of ignition.
The gas hose must not be twisted or bent.
If a gas leak is found or suspected, immediately turn off the gas cylinder,
switch the heater off and DO NOT use again until it has been checked by a
qualified service centre. If the heater is installed indoors, provide good
ventilation by opening doors and windows completely. DO NOT produce sparks or
open flames.
Ensure the fan is operating correctly before lighting the burners.
If the heater has to work for a long periods at its maximum capacity it is
possible that ice will form on the cylinder. This is due to excessive vapour
withdrawal. NEVER heat the cylinder for this or any other reason. To avoid
this effect or at least reduce it, use a large cylinder or at least two
cylinders linked together, see fig.1.
‰ WARNING! Disconnect heater from mains electrical supply and gas cylinder
before servicing or performing maintenance. Replace or repair damaged parts.
Use genuine parts only. Unauthorised parts may be dangerous and will
invalidate the warranty.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience or
knowledge if they have been given supervision or instruction concerning the
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and maintenance shall not be undertaken by children without
supervision.
Children of less than 3 years should be kept away unless continuously
supervised.
INTRODUCTION
61,000-102,000Btu/hr (18-30KW) variable output Propane Space Warmer®. Features safety solenoid valve which prevents the unit from leaking gas and safely ignites by the Piezo push-button ignition system. Supplied with a fully approved gas regulator and hose. The Space Warmer® is fan assisted and as the fuel is completely burned it leaves no oily residue like you may experience when using other types of fuel heaters. There is no odour, except for the few seconds during start-up and the unit runs a little more quietly since they do not need a compressor to drive the fuel to the burner. Heats an area of 15,900ft³(450m³) with a fuel consumption of 1.3-2.18kg/hr.
SPECIFICATION
Model no: …………………………………………………….. LP100.V7
Airflow: …………………………………………………………….. 380cfm
Fuel Consumption: …………………………………….. 1.3-2.18kg/hr
Fuel: ………………………………………………………………..Propane
Fuse Rating: ……………………………………………………………. 5A
Heated Area: …………………………………………15,900ft³(450m³)
Output: ………………………….. 61,000-102,000Btu/hr(18-30kW)
Power Supply Cable Length:…………………………………… 1.2m
Supply: …………………………………………………………………230V
OPERATION
4.1. Refer to instructions in Safety section 1 above.
4.2. Safety clearance see fig.2.
4.3. Connect gas supply hose to pressure regulator and connect regulator to a
suitable LPG cylinder (left hand threaded nut).
4.3.1. Open the gas cylinder tap and check supply hose and fittings for gas
leaks. Use an approved leak detector or soapy water.
‰ WARNING! NEVER USE NAKED FLAMES
4.4. Connect to mains power.
4.5. IGNITION
4.5.1. Turn the power switch to position “I” and check the fan starts running
correctly.
4.5.2. Push the gas valve button and repeatedly push the piezoelectric lighter
until the flame lights up see fig.3.
CAUTION If ignition is difficult or irregular before repeating the
ignition operations make sure that the fan is not locked and that the air
inlet and outlet are unobstructed.
4.6. SWITCH OFF
4.6.1. To stop the heater shut off the gas cylinder tap.
4.6.2. Let the fan run until the flame shuts down and then turn the fan switch
to position “O”.
4.7. ASPHYXIATION HAZARD
DO NOT use in domestic situations.
DO NOT use in unventilated areas. The flow of combustion and ventilation air
must not be obstructed. Proper ventilation air must be provided to support the
combustion.
‰ WARNING! If gas is smelt immediately switch off appliance at the gas
bottle. Check the appliance for leaks using an approved leak detector, if the
leak can not be found switch off gas supply and seek professional help. Be
aware that in the event of a gas leak ensure that the area is fully
ventilated and any form of ignition should be avoided.
MAINTENANCE
5.1. Repairs and maintenance must only be carried out by qualified personnel.
5.2. The heater must be checked by a qualified technician at least once a
year.
5.3. Regularly check the condition of the gas hose and gas regulator. If it
must be replaced only use genuine spare parts. Failure to do so may result in
personal injury and will invalidate the warranty.
5.4. Check the starting electrode position, see fig.4.
5.5. Check the connections of the safety thermostat and of the thermocouple:
they must always be clean.
5.6. If necessary clean the fan blade and the inside of the heater using
compressed air.
‰ WARNING: AIR CONTAMINANTS
Air contaminants taken into the heater will damage the unit, cause health
problems and safety issues.
For example: Body shop filler dust and overspray dust will clog the burner
diffuser, contaminate the combustion chamber and damage the internal parts of
the heater. If contaminants are present the heater must be supplied with
ducted clean air.
Please note that any parts damaged by filler dust or overspray dust will not
be covered by warranty. Additionally a cleaning charge will be made for any
heaters damaged by filler dust or overspray dust.
TROUBLESHOOTING
Problem | Causes | Solution |
---|---|---|
Motor does not work | No electrical supply | Check terminal board with a tester |
Motor works but the burner does not light up and after a few seconds the
heater stops| The gas cylinder tap is closed| Open the gas tap
The gas cylinder is empty| Use a new cylinder
The nozzle is obstructed| Remove the nozzle and clean it
The solenoid gas valve is not open| Check that the solenoid valve works
There is no spark| Check the position of the electrode
The burner lights up but after a few seconds the heater stops| Defective
connection between sensor and safety device| Check and connect properly
Defective safety device| Replace the safety device
The heater stops during operation| Insufficient air flow| Check that the motor
works properly
| Insufficient gas supply due to ice formation on the cylinder| Check and use
a larger cylinder or two cylinders connected together
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice. Please note that other versions of this product are available.
If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk
or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Information requirements for gaseous/liquid fuel local space heaters
Model identifier(s): LP100.V7
Indirect heating functionality:| Yes| No
Direct heat output: 30.0 (kW)| Indirect heat output: N/A| (kW)
Fuel| Space heating emissions NOx nitrogen oxides
Select fuel type:| Gaseous| Liquid| Specify: G30| 120.41| [mg/kWhinput] (GCV)
Item| Symbol| Value| Unit| Item| Symbol| Value| Unit
Heat output| Useful efficiency (NCV)
Nominal heat output| Pnom| 30.0| kW| Useful efficiency at nominal heat
output| ῃth,nom| 100| %
Minimum heat output (indicative)| Pmin| 18.0| kW| Useful efficiency at
minimum heat output (indicative)| ῃth,min| 100| %
Auxiliary electricity consumption| Type of heat output/room
temperature control (select one)
At nominal heat output| elmax| N/A| kW| Single stage heat output, no room
temperature control| Yes No
At minimum heat output| elmin| N/A| kW| Two or more manual stages, no room
temperature control| Yes No
In standby mode| elSB| N/A| kW| With mechanical thermostat room
temperature control| Yes No
* Enter figure or NA| With electronic room temperature control| Yes
No
With electronic room temperature control plus day timer| Yes No
With electronic room temperature control plus week timer| Yes No
Other control options (multiple selections possible)
Room temperature control, with presence detection| Yes No
Room temperature control, with open window detection| Yes No
With distance control option| Yes No
With adaptive start control| Yes No
Permanent pilot flame power requirement| With working time limitation|
Yes No
Pilot flame power required (if applicable)*| Ppilot| N/A| kW| With black
bulb sensor| Yes No
The seasonal space heating energy efficiency ƞs
Item| Symbol| Value| Unit
The seasonal space heating Energy efficiency in active mode| ƞs,on| 100| %
The seasonal space heating energy efficiency ƞs| ƞs| 91.0| %
Energy efficiency classes| A
Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St
Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk
v1| | | | | | ERP Table 1
Sealey Group, Kempson Way, Suffolk Business Park,
Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk
****www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
LP100.V7 Issue 3 (H,2,3) 19/04/23