SUPREME DRI-BUBBLE Hand Dryer
Product Information
Specifications
- Cover: ABS ION pure infused coating
- Motor: Digital brushless DC Motor 300W. Max 30,000 RPM; Quiet Mode 21,000 RPM
- Power: Max 320W / 720W total with heater; Quiet Mode: 130W / 530W total with heater; Standby < 0.5W
- Element: 400W – Switchable
- Rating: 220-240V AC, 50Hz, IPX3
- Filtration: HEPA (H13)
- Local Air Sterilisation: UV lamp & plasma ion generator operates sterilisation mode 1 hour on / 1 hour off cycle – Power 12W, Airspeed 17 m/s
- Switching: Infrared sensor with blue light assist
- Sound Levels: Max 72 dBA @ 1m; Quiet Mode 67dBA @ 1m
- Air Velocity: Max: 96 m/s (345km/h); Quiet Mode 65 m/s
- Air Volume: Max: 84m3/hr; Quiet Mode 57m3/hr
- Dimensions: 323H x 271W x 145D mm
- Weight: 2.6kg
- Warranty: The Supreme Comprehensive Hand Dryer Warranty – 60 Month Limited Warranty
- Standards: Complies with New Zealand and Australian Standards
- Recommended Mounting Heights:
- Men’s washroom: 1400mm
- Ladies’ washroom: 1365mm
- Children’s washroom 10-13yrs: 1208mm
- Children’s washroom 7-10yrs: 1128mm
- Children’s washroom 4-7yrs: 1028mm
- Disabled Person’s: 1150mm
Product Usage Instructions
Installation Instructions
-
1. **Wall Bracket Removal:**
- Place the main cover on a cloth to avoid marking its surface.
- Using the security key provided, remove one security screw located on the bottom of the unit.
- Pull down the wall mounting bracket and remove it from the unit.
- Positioning:
- Mark the location on the wall with a pencil using the mounting template provided.
- Pre-drill the wall in the marked location using an 8mm drill, insert the plastic anchors and tap flush to the wall.
Note: The unit must be mounted on a flat vertical wall capable of supporting the full weight of the unit.
Installing Power Cable and Connection Terminal Block:
- Pull the cable through the hole in the wall mounting bracket ensuring it is long enough to route correctly.
Note: The cable must sit in the dedicated channel.
FAQ
-
Q: What is the warranty period for the Supreme DRI-BUBBLE Hand Dryer?
A: The warranty period for this hand dryer is 60 months under the Supreme Comprehensive Hand Dryer Warranty. -
Q: What are the sound levels of this hand dryer?
A: The maximum sound level is 72 dBA at a distance of 1 meter, while in Quiet Mode it is 67 dBA at the same distance.
General Safety Information
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
- Failure to disconnect the power source before installation can result in serious injury or death from electric shock. Always disconnect the power source before servicing or installing the hand dryer.
- Fixed wiring is recommended for all installations. Wiring should emerge from the wall in the position marked on the mounting diagram. All fi xed wiring should incorporate a switch or breaker with a contract separation of at least 3mm in all poles.
- SPL (2021) Ltd accepts no responsibility for any damage or injury to property or persons caused by improper, incorrect or unreasonable use or installation.
- Failure to properly ground this unit could result in severe electrical shock and/or death. This hand dryer must be properly grounded (Earthed) for safe operation. An identifi ed ground connection point is supplied on the chassis of the hand dryer. We recommend GFCI protection in wet or damp locations or as required by local code.
- Risk of fi re, personal injury or property damage are possible if local codes, or safety recommendations are not followed. Installation must be carried out by a qualifi ed person in accordance with all local wiring regulations.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
- The instructions contained within the Mounting Template must be followed carefully when installing this unit. Failure to accurately follow the instructions may result in the incorrect operation of this unit, damage to property and/or personal injury.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Do not insert objects into the air outlet, doing so can be hazardous and could result in electric shock.
- Do not obstruct the air inlets or outlets in any way.
- Do service your hand dryer at regular intervals.
Operating Instruction and Parts Manual
Please read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all
safety information. Failure to comply with instructions could result in
personal injury and/or property damage. Retain instructions for future
reference.
Supreme DRI-BUBBLE Hand Dryer
The Supreme dri-bubble wall mounted high speed hand dryer with unique docking
bracket to allow for self service, maintenance and replacement. Ultra hygienic
HEPA filtration and UV-C sterilisation.
Specifications
- Cover ABS ION pure infused coating
- Motor Digital brushless DC Motor 300W. Max 30,000 RPM; Quiet Mode 21,000 RPM
- Power Max 320W / 720W total with heater; Quiet Mode: 130W / 530W total with heater; Standby < 0.5W
- Element 400W – Switchable
- Rating 220-240V AC , 50Hz, IPX3
- Filtration HEPA (H13)
- Local Air Sterilisation UV lamp & plasma ion generator operates sterilisation mode 1 hour on / 1 hour off cycle – Power 12W, Airspeed 17 m/s
- Switching Infrared sensor with blue light assist
- Sound Levels Max 72 dBA @ 1m; Quiet Mode 67dBA @ 1m
- Air Velocity Max: 96 m/s (345km/h); Quiet Mode 65 m/s
- Air Volume Max: 84m3/hr; Quiet Mode 57m3/hr
- Dimensions 323H x 271W x 145D mm
- Weight 2.6kg
- Warranty The Supreme Comprehensive Hand Dryer Warranty – 60 Month Limited Warranty
- Standards Complies with New Zealand and Australian Standards
Recommended Mounting Heights
From floor to top screws:
- Men’s washroom 1400mm
- Ladies’ washroom 1365mm
- Children’s washroom 10-13yrs 1208mm
- Children’s washroom 7-10yrs 1128mm
- Children’s washroom 4-7yrs 1028mm
- Disabled Person’s 1150mm
Planning
We suggest that one hand dryer be installed for every two hand basins.
NOTE : Dryer should not be installed over bench tops or a reflective
surface.
Installation Instructions
Wall Bracket Removal
- Place the main cover on a cloth to avoid marking its surface.
- Using the security key provided, remove one security screw located on the bottom of the unit. (Fig 2).
- Pull down the wall mounting bracket and remove from the unit. (Fig 3).
Positioning
- Mark the location on the wall with a pencil. Use the mounting template provided to mark three fixing points (Fig 4).
- Pre-drill the wall in the marked location using 8mm drill, insert the plastic anchors and tap flush to the wall. Provide a proper cable exit (Fig 5).
NOTE : The unit must be mounted on a flat vertical wall capable of supporting the full weight of the unit.
Installing Power Cable and Connection Terminal Block
- Pull the cable through the hole in the wall mounting bracket. Ensure the cable is long enough to route correctly through the wall mounting bracket to the terminal block (Fig 6).
- The cable must sit in the dedicated channel. If the cable is coming through the power cable entry from outside, it is recommended that the cable is routed via the 3 bosses as in Fig 6B.
- As shown below, connect the cable to the terminal block.
- Screw in the terminal block.
- Fix the wall mounting bracket to the wall. Screw to the wall using the appropriate fitting (Fig 6A).
- Fix the cable cover with the screw on the wall mounting bracket.
CAUTION : Connect the ground wire to the terminal block marked Do not over-tighten and crush the power cable.
Fix the Main Unit to Wall Mounting Bracket
- Position the unit centrally above the wall mounting bracket so the metal bracket on the rear is positioned over the mating part of the wall bracket moulding. Keeping the dryer firmly against the wall, slowly slide the dryer down until there is no further movement. The dryer should then be electrically connected (Fig 9).
- Insert and tighten the security screw seated on the bottom of the surface (Fig 9A).
- Turn the unit on and test the operation. The LED light on the cover should flash 3 times with a red light after the power supply has been correctly connected and followed by a continuous light white LED.
Note : If the LED light remains off, the unit must be refitted correctly
The unit has a built-in UV-C lamp, to avoid exposure to direct germicidal UV rays.
Options: Heater, Quiet Mode & Air Sterilisation
IMPORTANT : Turn the power OFF at the isolator switch before performing the next steps.
-
Remove one security screw located on the bottom of the unit, using the security hex key provided (Fig 2).
-
Lift the unit off the wall mounting bracket.
NOTE : Ensure the LED light on the front of the unit is OFF before opening the front cover, if the LED light is still ON, wait unit the light goes off. -
Remove two cover screws from the bottom of the dryer using the security hex key (Fig 7). Screws are designed to remain captive within the channel.
-
Remove one cover screw from the back of unit, using a phillips screwdriver (Fig 7A).
-
Lift the front cover off the unit (Fig 8).
-
To turn the Heater on/off, use the middle switch shown in Fig 8A (Factory set ON)
-
To change to Quiet Mode, use the switch on the right shown in Fig 8A (Factory set OFF).
-
To turn on/off Air Sterilisation, use the switch on left shown in Fig 8A (Factory set ON).
HEPA Filter Replacing
The red flashing LED light on the front of unit indicated HEPA filter needs replacing. The filter functions for approximately 60,000 operations.
-
Remove the filter cover shown in pages 7 & 8.
-
Turn the filter cover to open direction (Fig 10). The dot is aligned with the arrow present on the motor cover (Fig 10A).
NOTE : Ensure the LED light on the front of the unit is OFF before opening the front cover, if the LED light is still ON, wait until the light goes off. 3. Remove the filter (Fig 10B). -
Replace with new HEPA filter. Ensure the dot on the filter cover is aligned with the arrow on the motor cover (Fig 10C).
-
Turn the filter cover to close direction. The dot is positioned to the right of the arrow on the motor cover (Fig 10A-A)
WARNING – HEPA filter will need to be replaced after 60,000 operations but will continue working for a further 15,000 operations without the benefits of the HEPA filter. At approximately 75,000 operations the red LED will begin to flash and the unit will stop working until a replacement filter is fitted.
UV-C Lamp Replacement
The sterilisation function of UV-C lamp will be weakened after 3 years use,
the UV-C lamp needs to be replaced to maintain proper function.
- Remove the filter cover and filter shown in pages 7 & 8.
- Remove the two cover screws on the UV-C lamp cover and remove UV-C lamp cover and pull the UV-C lamp wire jack from the UV light board.(Fig 11).
- Insert the new UV-C lamp and replace the UV-C lamp cover. Tighten the two screws and replace the wire jack on the UV-C lamp board.
- Replace the filter then re-attach front cover.
NOTE : On power up should the red LED continue to flash, refit the filter
Maintenance and Cleaning
Regular Maintenance
Cleaning and maintenance must not be undertaken until the unit has been
removed from the mounting bracket and power has been disconnected
- Regularly clean the outer casing using a soft, damp cloth to gently wipe away any dirt
CAUTION : Never use abrasives or chemical to clean the cover. Do not soak.
Periodical Deep Clean
- Use security hex key to remove the top cover security screws.
- Remove the cover.
- Clean all dust and lint from the interior of the hand dryer.
- Replace the cover.
- Wipe the cover with a damp cloth
Register your Hand Dryer
- Scan the QR code using the camera app on your smartphone.
- Upon registering you will receive a 5% discount code for your first online order and we will send you one annual maintenance reminder email.
Troubleshooting
Symptom | Possible Cause | Corrective Action |
---|---|---|
The red LED continues to flash after replacing HEPA filter | The filter is not |
fitted
correctly
| Refit the HEPA filter, making sure the dot is aligned to the right arrow on
the motor cover.
Dryer fails to start| Defective PCB| If no LEDs are list above and the supply
circuit is confirmed to be active, replace the PCB and transformer.
HEPA filter needs replacing (LED will be flashing red)| HEPA filter will need
to be replaced after 60,000 operations but will continue working for a further
15,000 operations without the benefits of the HEPA filter. At approximately
75,000 operations the red LED will
begin to flash and the unit will stop working until a replacement filter is fitted.
Supreme Comprehensive Warranty
Your Supreme Hand Dryer is fully guaranteed against defective materials and
faulty workmanship commencing from the date of sale (according to SPL’s
records), subject to it being installed and maintained by the manufacturer’s
instructions.
SPL (2021) Limited warrants that should any part of the dryer fail within the
given warranty period (2- 5 years product dependant), it will be remedied by
SPL. The dryer should be returned to SPL (2021) Limited for all warranty
claims. The cost of cartage will be payable by the customer.
This warranty excludes:
- Incorrect installation, or installation that does not specifically follow the installation guidelines supplied
- Failure to follow the manufacturer’s maintenance instructions
- Damage/Failure resulting from:
- the use of non-authorised parts
- authorised parts not installed by the manufacturer’s instructions
- accidental damage, negligent use, misuse, vandalism, neglect
- damage caused either directly or indirectly by external sources (power outages, power surges, incorrect power supply, natural disaster, or insect infestation)
- Water ingress caused by property maintenance or flooding
- Negligent cleaning practices (water ingress, harmful chemicals etc)
The above includes consequential damage to any other goods, furnishings, or property.
- Normal wear and tear and consumable parts (HEPA filters, UV C Lamps, fuses, motor brushes etc)
- This warranty does not displace any statutory warranty about the dryer but any liability of SPL (2021) Limited under any statutory warranty will be limited to a replacement or repair of the dryer or payment of the cost of such replacement or repair at the sole discretion of SPL (2021) Limited
Note : Our Warranty only extends to products purchased and installed in
New Zealand.
SPL Limited PO Box 437, Cambridge 3450 New Zealand
p. +64 7 823 5790
e. office@splwashrooms.co.nz
splwashrooms.co.nz
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>