12605 Hydro Mag Recirculating Water Pumps
CARE AND OPERATING INSTRUCTIONS
Model 19
ITEM # 02519
ITEM # 40120
Model 19 Pump With filter
ITEM #02019
Model 19 Pump
With Fountain & Block Foam Filter
ITEM # 02273
WARNING!! PONDS ARE DANGEROUS TO SMALL CHILDREN!
NEVER LEAVE CHILDREN UNSUPERVISED NEAR A POND
INTRODUCTION
Thank you for purchasing this Danner water pump. This submersible or in-line
pump provides a continuous stream of water with an adjustable flow control.
Danner pumps are carefully inspected and tested to insure both safety and
operating performance. However, failure to follow the instructions and
warnings in this manual may result in pump damage and/or serious injury. Be
sure to read and save this manual for future reference.
The Model 1.9 pump has a number of features which make it versatile.
A1/2 inside diameter tube may be slipped over the outlet ora 1/4 pipe thread
fitting can be used. The pump also comes with an elbow which will accept 3/8
ID tubing or 1/2 ID soft tubing. The elbow is for submersible use only. The
elbow directs the soft tubing horizontally to prevent kinks. When there is
limited room in the base of statuary, the pump can be placed with the screen
inlet down for operation in shallow water.
The kits that utilize the 190 pump both include filtration media and a bell
shaped fountain. The filter media keep the water clean and protect the pump.
In most set-ups they can be rinsed and re-used several times before needing
replacement.
ELECTRICAL PRECAUTIONS
Always use a properly grounded outlet. Do not immerse plug in water. DO NOT
REACH INTO WATER TO REMOVE PLUG.TURN OFF CIRCUIT FIRST. A “drip loop”should be
provided. The ‘drip loop”is a loop in the line cord below the level of the
receptacle or plug that prevents water from running along the cord. The
National Electric Code requires that a ground fault circuit interrupter (GFCI)
be installed on the branch circuit supplying fountain or pond equipment. Your
dealer can supply GFCl units.
NEVER REMOVE THE GROUND PIN FROM PLUG. WARNING: FOR YOUR PROTECTION ALWAYS
UNPLUG THE UNIT FROM ITS POWER SOURCE BEFORE INSTALLING OR SERVICING. SHOULD
THE UNIT APPEAR TO BE NOT WORKING DO NOT REACH, REMOVE OR DISASSEMBLE UNIT
BEFORE YOU DISCONNECT POWER. The pump is intended to pump water only. It
cannot be used to pump oils, solvents or gasoline.
Subscribe to our YouTube Channel and view all of our product videos.
PUMP OPERATION
Centrifugal pumps will not pump if the housing is filled witl ai’]nThginIet
musfbe Iled with wategn Unless the air can escape from the outlet, the pump
will not pump water.
The pump included with the Pondmaster 190 will pump up to 190 gallons per
hour. If you chose not to use the Bell Fountain head, a %” ID tubing will fit
over the nozzle. This can power a statue or waterfall.
NOTE: There are a number of things which will reduce the flow of a pump:
- Dirty or clogged filter.
- Small diameter hose ( do not use a 1/2″ ID hose over 6′ long).
- FLOW THROUGH 15′ OF 1/2″ FLEX TUBING IS REDUCED TO less than 160 GPH @ ZERO HEAD.
- The height the water is pumped. (measured from the pond surface to the hose discharge).
- If youmust connect toa small fitting on a statue, reduce the size of the hose at the statue, not at the pump end of the hose.
INLINE USE
The 1.9 pump is suitable for inline use by following these precautions:
- Do not use non-threaded elbow for inline applications.
- Use several wraps of Teflon tape (Not included) on all threaded fittings. (A) © Do NOT overtighten threaded adapters.”
- Leave a gap above the Flow Control Lever. (B)
- Always check inline set-up for leakage before leaving unattended.
PMK 190 FILTER KIT
The 1.9 pump (with the filter cover and filter pad removed) slides into the dovetail tracks in the filter plate. The filter plate can be guided into the middle of the pond by tying a line to the filter handle. The tie line is also useful to remove the filter for service; do not pull on the power cord. Replace elbow with the bell fountain head to beautify your set-up as well as control spray and splashing.
FOUNTAIN KIT
Place entire 1.9 pump into foam block and insert fountain assembly onto pump
spout. OPERATING TIP for 02019 filter
In some ponds, as the water is filtered, dissolved gases will separate out of
the pond water during the filtering process. This may make the filter float to
the surface as the gases collect in the filter box. We recommend thata few
small pieces of slate or flat stones be placed in the lower base of the filter
by removing the cover and filter media from the compartment and placing the
weights into the base.
MAINTENANCE – FILTER and FOAM BLOCK
To service filter media, disconnect power to pump and pull the filter from the
pond using the handle on filter (not line cord). Lift the tab on the side
opposite the ump, lift the handle and slide the cover toward the pump to
disengage from ousing. For foam block simply lift pump up from foam cavity.
Keep in mind that phosr)hates which are present in many water supplies, joined
with the Increased biological load present in most man made ponds make an
ideal breeding ground for algae. Decreasing the amount of bright sunlight your
pond is exposed to and eIiminatinlg overfeeding of pond fish are two ways to
help regulate algae growth.
No mechanicalfiltering system alone will eliminate algae growth.
Al filter media can be easily removed from filter and quickly rinsed. If you
wish to maintain the biological filter bed do not soak or wash filter pads in
chlorinated water. Use water from thelpond -When the pads start to mat down or
if the foam block flakes or tears, it should be replaced.
MAINTENANCE – PUMP
Periodically the pump will need to be cleaned when the flow slows down or
stops. To clean, unplug and remove from water. Slip off pre-filter cover and
wash out the foam pre-filter pad.
After repeated washings the foam will need to be replaced, After a period of
time deposits may build up inside the pump cover. Remove the four screws which
hold the pump cover to the motor housing and pull cover straight away from the
pump body. Pulling on an angle will stress and break the ceramic impeller
shaft. The impeller is the only serviceable item. It can be cleaned or
replaced. If it is worn or broken the entire impeller assembly can be
replaced. This will restore the pump to original capacity. Do not overtighten
screws when assembling. Check that O-ring is seated into groove in pump cover.
If pump fails to start recheck that impeller is not blocked by debris. For
best results the minimum water level depth should be 2 inches. Pumps taken out
of service with the fluid inside run the risk of forming a crust which may
prevent subse-quent starting. Magnet im pellet assembly must be routinely
cleaned to remove accumula-tions of scale or calcium. This procedure should be
done at least once every three months – or more often if the water conditions
require it. Salt water and hard water environments require more frequent
cleaning.Pondmaster® PUMPGUARD™ WATER PUMP
MAINTENANCE SOLUTION (sold separately) will instantly loosen scale, lime, rust
and other detritus from moving parts and impeller chamber. Most build-up can
be removed without disassembling the pump.
Always check cord for sharp bends which can cause premature cracking. Do not
lift the pump with the cord. Running the pump in chlorine or bleach solution
is not recom-mended. Do not allow pump to run dry.
PUMPGUARD™ maintenance INSTRUCTIONS
- DISCONNECT POWER TO PUMP.
- REMOVE PUMP FROM WATER.
- POSITION PUMP WITH VOLUTE INLET FACING UPWARDS.
- POUR PUMPGUARD INTO VOLUTE INLET UNTIL FULL.
- ALLOW TO SOAK FOR 2 TO 3 MINUTES.
- THOROUGHLY RINSE WITH CLEAN WATER.
- PLACE PUMP BACK INTO SERVICE.
PUMPGUARD”™ ‘is available in three sizes:
4 oz. – Impeller /Volute treatment ——— ITEM # 03905
32 oz. – Soak/Dunk impeller treatment —ITEM # 03907
128 oz. – Commercial Size ——————- ITEM # 03909
PUMP PARTS REFERENCE
1.9 Magnetic Drive Pump
#| Description
1| Motor
2| Impeller Assembly
3| Cover w/ 0-Ring & Flow control
4| Non-Threaded Elbowx
5| Screw set’
6| Filter Pad
7| Filter Cover
NOTE:
Parts with asterisk () are listed here for reference only and may not be
available.TTEM # 12195
Filter pad replacement pack for Garden Pond Filter includes:
2 Foam Filter 1 pc
3 Fiber Filters 2 pes
FILTER & FOUNTAIN PARTS REFERENCE
# | Description |
---|---|
1 | Filter Cover* |
2 | Foam Filter |
3 | Fiber Filters |
4 | Filter Bottom* |
5 | Bell Fountain* |
6 | Bell Fountain* |
7 | Foam Block |
*NOTE:*
Parts with asterisk () are listed here for reference only and may not be
available.
ITEM # 12600
Replacement foam block for Bell Fountain includes:
7 Foam Block 1 pc LIMITED WARRANTY**
Danner pumps are warranted against failure due to defects in materials and/or
workmanship for 5 years from date of purchase. This warranty covers defects
occurring under normal use. The warranty and remedies set forth herein are
conditional upon proper installation, use, maintenance, storage, and
conformance with the applicable use. It will be based upon Danner Mfg.
discretion as to whether the defects are o?manufaduring origin.
For warranty repair, return only the part that is defective to our factory.
Please include a dated proof of purchase and $5.00 for postage and handling.
Any damages due to improper installation are not covered by this warranty.
This warranty does not apply to appearance or accessory items. This warranty
does not include damage due to handling, transportation, unpacking, setup,
installation, repair or replacement of parts supplied by any other than Danner
Mfg.; improper maintenance, modification or repairs by the purchaser; abuse,
misuse, neglect, accident, fire, flood, or other acts of God. Any oral
statements about this product made by the seller, the manufacturer, their
representatives or any other parties do not constitute warranties and shall
not be relied upon by the user and are not part of this contract. Neither the
seller nor the manufacturer shal‘l’ be liable for any injury, loss or damages,
direct, incidental, or consequential, including but not limited to incidental
or consequential damage for lost profits, lost sales, injury, and inability to
use the product and the user agrees that no other remedy is available. Before
using, the user shall determine the suitability of the product for their
intended use and the user shall assume all risk liability whatsoever in
connection therewith. To validate this warranty, keep your proof of purchase
(copy of sales receipt). Warranty covers the repair or prorated replacement of
the Danner Mfg. products. Danner Mfg. denies all liability for any other loss
including but not limited to loss of equipment, income, livestock, or personal
injury.
THE FOLLOWING VOIDS WARRANTY: LINE CORD OR PLUG IS ALTERED OR CUT, PRODUCT
LABELS ARE DEFACED OR REMOVED. PRODUCT IS IMPROPERLY INSTALLED OR MAINTAINED
BY USER OR THEIR AGENT. PRODUCT IS ABUSED, MISUSED, OR DAMAGED BY USER OR
THEIR AGENT.
PRODUCT IS NOT REMOVED FROM SERVICE AND DRIED DURING FREEZING CONDITIONS.
EG Danner Mfg. Inc.
160 Oval Drive
Islandia, NY 11749
TEL: 631-234-5261 or 800-458-5876
Website: www.dannermfg.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>