Carrier BLUEDGE Chiller Plant Energy Audit User Guide

June 1, 2024
Carrier

Carrier-logo

Carrier BLUEDGE Chiller Plant Energy Audit

Carrier-BLUEDGE-Chiller-Plant-Energy-Audit-PRODUCT

Product Information

  • Specifications
    • Product   Name: Chiller Plant Energy Audit
    • Functionality: Improve energy efficiency, reduce emissions, and save costs
    • Target Market: Europe
    • Key Features:
    • Energy audit to assess current performance and propose energy-saving measures
    • Expert team for data gathering, performance baselines, and gap analysis
    • Recommendations for energy conservation and sustainability
    • Advanced calculation tool for efficiency improvement

Product Usage Instructions

  • Energy Audit Process
    • Our team of experts will conduct an energy audit to establish the existing performance baseline and provide recommendations for energy-saving measures.
  • Audit Report Analysis
    • The audit report will include energy conservation measures, system operations optimization, and controls to improve overall plant efficiency.
  • Gathering Data
    • Data will be collected to set benchmarks, conduct gap analysis, and recommend suitable energy conservation measures.
  • Advanced Calculation Tool Usage
    • Utilize the advanced calculation tool provided to improve energy and operational efficiency, reduce gas emissions, and achieve cost savings.

FAQs

  • Q: What are the key benefits of the energy audit?
    • A: The key benefits include improved energy and operational efficiency, reduced gas emissions, and cost savings.
  • Q: How can I achieve a return on investment with the recommended measures?
    • A: By implementing the recommended measures like installing high-efficiency chillers and optimizing system operations, you can achieve a return on investment of 30%.
  • Q: What are the projected efficiency improvements with the proposed changes?
    • A: The efficiency is projected to improve from 1.46 kW/kW to 0.68 kW/kW, resulting in a 53% efficiency improvement.

INTRODUCTION

YOUR PROACTIVE APPROACH TO REDUCE YOUR ENERGY CONSUMPTION AND ANTICIPATE EUROPEAN REGULATIONS

  • HVAC* installations represent approximately 35% of buildings energy consumption**, a real challenge considering the critical energy cost increase we are facing in Europe.
  • Climate change and environmental degradation are an existential threat to Europe and the world.
  • To overcome this challenge, the European Commission, with the Green Deal and REPowerEU initiatives, proposes ambitious targets in terms of energy efficiency and greenhouse emissions.
  • An energy audit is an assessment of the current performance and operation of a chiller plant, highlighting areas of concern and potential improvements, to propose to our customers with suitable measures for energy conservation, sustainability and decarbonization.
  • Our BluEdge® service team can conduct an onsite health check and present you an audit report.
  • Heating, Ventilating, and Air-Conditioning. **U.S. Department of Energy Buildings Energy Data Book, 2015.

OUR SOLUTION

OUR SOLUTION TO IMPROVE YOUR PLANT’S EFFICIENCY

ENERGY AUDIT

  • Our team of experts will conduct an energy audit, the first step in establishing the existing performance baseline to provide recommendations for appropriate energy saving measures.

AUDIT REPORT

  • Energy conservation measures, incorporate controls, and system operations optimisation to improve overall plant efficiency.
  • We provide innovative solutions to maximise overall building efficiency while providing a strong return on investment.

Carrier-BLUEDGE-Chiller-Plant-Energy-Audit-fig-1 \(2\)

Advanced Calculation Tool

  • Advanced and easy-to-use calculation tool: collection of basic necessary data.
  • Remote data collection via GMS and connected services.
  • Generate a clear automated report with key information.

Key Benefits

  • Enables planning for modernization.
  • Report with clear recommendations and projected results.
  • Visualization of plant’s efficiency improvement, energy savings, payback period, and CO2eq savings.
  • Support and expertise from the BluEdge Service team.

With our expertise, achieve benefits and positive impacts in net earnings, key performance indicators, and corporate social responsibility, based on your chiller plant requirements and sustainability goals.

AUDIT REPORT

Benefits from our report, with clear recommendations and projected results.

EXECUTIVE SUMMARY

  • Proposed system
    • Chiller plant configuration 4×550 kW
    • Peak building cooling load 400 kW
    • Design chilled water supply temperature 6.67°C

The above performance data are nominal readings. Actual performance may deviate subject to operating conditions.

Final configuration

Energy conservation measures

  1. Install new 1X600 kW new high-efficiency VFD chiller
  2. Install a new set of 8 X chilled water pumps, 3 X condenser water pumps, and 3 X cooling towers fitted with VSD
  3. Install chiller plant system manager with advanced optimization control algorithm.

$ 2.7M Capital Investment

Projected efficiency

EXAMPLE OF GRAPHS

EXAMPLE OF GRAPHS PRE/POST RETROFIT

Carrier-BLUEDGE-Chiller-Plant-Energy-Audit-fig-1 \(7\) Carrier-BLUEDGE-Chiller-Plant-Energy-Audit-fig-1
\(8\)

CASE STUDY

  • HOSPITALITY
    • Our customer is one of the largest and famous hospitality companies in the world. Delivering exceptional guest experience is part of their main value.
    • One of its hotels located in the city center of Rotterdam (the Netherlands), asked our team for an Energy Audit of its old chillers (other brand chillers).
    • The objective was double: first, to meet the requirements of the company in satisfying guest’s comfort with lower noise. Secondly, to be compliant with the new regulations in terms of energy efficiency and gas emissions.
    • After conducting an energy audit, our BluEdge service team based in the Netherlands, recommended replacing the existing chillers system with a complete and optimal solution, including 2 x optimized air-cooled scroll chillers with new control for plant room supervision and new variable speed pumps.
  • Targets have been met, and our customer could benefit from:
    • 72% of energy savings.
    • A ROI (return on Investment) < 3 years.
    • Low sound for its guest’s comfort and localization in the city center.
    • Contact your local representative or visit www.carrier.com/eu/.
    • CARRIER / 06-2023 – C2023 Carrier. All Rights Reserved.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>