APPENDIX – INSTALLING APPLICATIONS NEEDED FOR DASHBOARD

To run DLM Dashboard the following must be installed on a local computer or virtual machine:

  • WSL (Windows Subsystem for Linux)
  • Ubuntu (installed as part of the WSL installation)
  • Docker
  • ESE (Edge Streaming Engine) running in the Docker environment
  • Niagara Workbench 4.10 or later

WSL, Docker, and ESE can be installed from the DLM Dashboard Sync application. Installation of Workbench is a separate process and not covered in this appendix.

NOTE: Install Workbench prior to beginning this process since it will need to be installed in order to complete the setup.

Prior to Installation

  1. Search for the “Turn Windows features on or off” Control Panel and open it.

  2. Check to see that the Hyper V, Virtual Machine Platform, and Windows Subsystem for Linux checkboxes are all selected. If any of them are not, select them.
    Prior to Installation

  3. Click OK, then restart the computer. This will cause a Windows update. You can then proceed with the DLM Dashboard Sync installation.
    NOTE: If Docker had previously been installed on the computer, it will need to be uninstalled before proceeding.

DLM Dashboard Sync Installation

  1. Download the file ESE Installer (version number).zip. Extract the file to a location of your choosing on the PC.

  2. Open the extracted file and look for the DLM Dashboard Sync application file. Double-click to install it. If you receive a security warning message, click More Info, and then Run Anyway. The DLM Dashboard Sync login screen will open. Enter your email and the password set up when your Legrand cloud account was originally set up. Then click Login.
    DLM Dashboard Sync Installation

  3. The DLM Dashoard Sync installer screen opens.
    DLM Dashboard Sync Installation

  4. Click Begin Installation. The installer begins installing WSL. An Ubuntu pop-up may or may not appear, as shown below. If it does appear, enter a User Name. You can choose whether or not to enter a password. If you do not, simply press Enter twice. If the Ubuntu screen does not appear, WSL installation continues until it completes.
    DLM Dashboard Sync Installation

  5. Once WSL installation completes, the Continue button appears. Click Continue.
    DLM Dashboard Sync Installation

  6. Docker installation begins. You are asked to enter the WSL password. If you created a password in the previous step, enter it, If you did not enter a password, or if the Ubuntu pop-up did not open, click Submit without entering anything.
    DLM Dashboard Sync Installation

  7. Docker installation continues. Once it completes, ESE installation begins. You are prompted to enter ESE credentials.
    DLM Dashboard Sync Installation

  8. Enter a User Name and Password. Write down the User Name and Password because you will need to enter them in Workbench. You must also enter the IP Address used by the PC. To find out the IP Address, open the Command Prompt and type “ipconfig”. The computer returns IP information. You will need the IPv4 Address. Close the Command prompt, enter the IP Address, and click Submit.
    DLM Dashboard Sync Installation

  9. The ESE Installation display changes to show “Generating Certs’, “Loading Docker Images”, and then “Installing ESE”. Once installation is complete two Windows pop-up dialogs appear asking if you want to allow the application to make changes. Click Yes for both of them. The display then changes to show a successful ESE connection.
    DLM Dashboard Sync Installation

  10. Click Export Certs. Windows Explorer opens. Select a folder to save the exported certificates. At this point you can close the DLM Dashboard Sync window. Installation is complete. The final step is to import the certificates into Workbench

Importing Certificates into Workbench

  1. Open Workbench.

  2. With Platform highlighted in the tree to the left, click Certificate Management on the right side. Then with the Certificate Management window open on the right, click Import.
    Importing Certificates into Workbench

  3. In the pop-up Import dialog, navigate to the folder where you stored the exported certs. The file you want to import is named “ese-client-pem.pem”. Select that file and click Open, then OK
    Importing Certificates into Workbench

  4. At this point, you may or may not see the cert file displayed in the list of local certificates.

  5. Click Application Director in the tree. After a few seconds, Workbench will display a lot of failed communication messages with the LMJA-8xxx. The LMJA-8xxx will need to be restarted before establishing communication with ESE. Click Restart.

  6. Once the LMJA-8xxx has finished restarting, you will continue to see communication error messages.

  7. Click Certificate Management in the tree, then click the Allowed Hosts tab on the right side. The host will display a red X, indicating that the connection failed. Right-click on the host and select Approve. Then click Yes. The icon changes to a green check
    Importing Certificates into Workbench

  8. Return to the Application Director. After a few seconds the LMJA-8xxx should begin displaying Publishing message, indicating that
    the LMJA-8xxx is now communicating with ESE
    Importing Certificates into Workbench

Customer Support

No. 32808 – 10/23 rev. 1
© Copyright 2022 Legrand All Rights Reserved.
© Copyright 2023 Tous droits réservés Legrand.
© Copyright 2022 Legrand Todos los derechos reservados.

800.879.8585
www.legrand.us/wattstopper

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals