FEIN 39410008000 GIXBE GIXS Machine Base User Manual
- June 15, 2024
- Fein
Table of Contents
- Assembly Instruction
- Symbols, abbreviations and terms used.
- For your safety.
- At a glance.
- Assembly instructions (figures 1 + 2).
- Electrical connection (GIXBE).
- Operating instructions.
- Emptying the collection box/ Replacing filter inserts (figure 4).
- Noise emission values (GIXBE).
- Repair and customer service.
- China RoHS Status Certificate
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FEIN 39410008000 GIXBE GIXS Machine Base User Manual
Assembly Instruction
Symbols, abbreviations and terms used.
The symbols in the Instruction Manual and on the machine shall aide in directing your attention to possible hazardous situations when working with this machine.
Symbol, character | Explanation |
---|---|
Do not touch the rotating parts of the machine. | |
Observe the instructions in the text or graphic opposite! | |
Make sure to read the enclosed documents such as the Instruction Manual and |
the General Safety Instructions.
| Before commencing this working step, pull the mains plug out of the socket.
Otherwise there may be danger of injury caused by unintentional starting of
the machine.
| Use eye protection during operation.
| Use ear protection during operation.
| Use a dust mask during operation.
| Use protective gloves during operation.
| Danger warning
| Confirms the conformity of the power tool with the directives of the
European Community.
| Worn out machine and other electrotechnical and electrical products should
be sorted separately for environmental-friendly recycling.
3~| Mains supply: three-phase alternating current
| Product with basic insulation plus additional insulation on touchable,
conductive parts connected to the protective conductor.
()**| may contain numbers and letters
Character| Unit of measurement, international| Unit of
measurement, national| Explanation
---|---|---|---
n| /min, min–1, rpm, r/min| rpm| Fan speed
P 1| W| W| Power input
U| V| V| Rated voltage
f| Hz| Hz| Frequency
| m3/h| m3/h| Flow rate
| hPa| hPa| Vacuum
| kg| kg| Weight according to EPTA-Procedure 01
| m, s, kg, A, mm, V,W, Hz, N, °C, dB,min, m/s2| m, s, kg, A, mm, V,W, Hz, N,
°C, dB,min, m/s2| Basic and derived units of measurement from the
international system of units SI.
For your safety.
Do not use this sub base before you have thoroughly read and completely
understood these operating instructions, including the figures,
specifications, and safety regulations.
Read and observe the operating instructions of the machine, which is to be
mounted to this sub base.
Please also observe the relevant national regulations on electrical safety and
occupational safety. Non-observance of the safety instructions in the said
documentation can lead to an electric shock, burns and/or severe injuries.
These operating instructions should be kept for later use and enclosed with
the device, should it be passed on or sold.
Intended use of the sub base.
The sub bases are intended for stationary assembly of GI100, GIE, GXE grinding
machines in weather-protected environments.
Special safety instructions.
Ensure stable positioning and a level set-up of the sub base. Fasten the sub
base to the floor. If the sub base tips over during working, this can cause
serious injuries. (figures 1 + 2)
Use suitable mounting material to mount the machine to the sub base. Faulty assembly can cause the machine to loosen from the sub base during operation and lead to serious accidents.
Before switching on, make sure that all clamping levers of the sub base are well tightened. If the machine suddenly drops or lowers, this can lead to serious accidents. GIXBE:
The plug of the extraction system may only be installed by a qualified electrician. The protective conductor in the mains socket must be connected to the protective earthing of the mains supply.
Pull the mains plug for maintenance and repairs!
If the extraction device is switched on unintentionally, this can lead to
serious injuries.
Have the electrical safety of the extraction system checked regularly in accordance with statutory provisions. For systems that have not been checked, there is danger of electric shock!
At a glance.
- On/Off switch (GIXBE)
- Rest
- Hose clamp (GIXBE)
- Extraction hose (GIXBE)
- Lock (GIXBE)
- Door (GIXBE)
- Frame (GIXBE)
- Filter insert (fine filter) (GIXBE)
- Filter insert (coarse filter) (GIXBE)
- Collection box (GIXBE)
- Lock latch (GIXBE)
- Fastening screws
Assembly instructions (figures 1 + 2).
Fasten the sub base to the floor using suitable dowel/bolt connections.
The connections must withstand the forces that arise during working.
Place the machine to be mounted onto the rest (2).
Because of the risk of accidents, this work must be carried out by persons who
are physically able to lift the high machine weight.
Fasten the machine to the rest with the corresponding fastening bolts (12).
Faulty assembly can cause the machine to tip over during operation and lead to
serious accidents. GIXBE: Mount the extraction hose (4) to the machine’s
extraction sleeve and tighten the hose clamp (3).
Electrical connection (GIXBE).
Observe mains voltage:
The mains voltage and the frequency of the power source must agree with the
data onthe type plate of the machine. Plug the mains plug of the extraction
system into the socket outlet on the machine provided for this purpose.
Operating instructions.
Switching on and off (GIXBE).
The extraction system is switched on and off with the On/Off switch (1).
Emptying the collection box/ Replacing filter inserts (figure 4).
Undo the locks (5) and open the door (6). Undo lock latch (11) and completely pull out the filter unit. Remove both filter inserts (8)/(9) from the frame(7). Clean the filter inserts with compressed air and empty the collection box. Before emptying, the contents of the chip/grinding-dust box must have cooled down sufficiently and may only be disposed of in suitable containers. Place the cleaned filter inserts (8)/(9) into the frame (7) with the correct side facing upward. Slide the filter unit into the guide and allow lock latch (11) to engage. Close the door (6).
Noise emission values (GIXBE).
A-weighted emission pressure power level measured at the workplace LpA (re 20
μPa), in decibels 76
Measuring uncertainty KpA, in decibels 3
Measured A-weighted sound power level
LwA (re 1 pW), in decibels 90
Measuring uncertainty KwA, in decibels 3
REMARK: The sum of the measured emission value and respective measuring
inaccuracy represents the upper limit of the values that can occur during
measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard (see last page in this Instruction Manual).
Repair and customer service.
Repairs may be carried out only by qualified persons in conformity with the
valid regulations. For repairs, we recommend our FEIN customer service centre,
the FEIN authorised service centres and FEIN agencies.
GIXBE: When the machine’s power supply cable is damaged, it must be
replaced using a specially prepared power supply cable, available from your
FEIN customer service agent.
The current spare parts list of this product can be found on the Internet under www.fein.com. Carry out the following maintenance regularly: Empty the collection box and clean the filter inserts. Replace the filter inserts in good time when the extraction performance decreases considerably. Remove any deposits in the housing
Warranty and liability.
The warranty for the product is valid in accordance with the legal regulations
in the country where it is marketed. In addition, FEIN also provides a
guarantee in accordance with the FEIN manufacturer’s warranty declaration. The
delivery scope may include only a part of the accessories described or shown
in this instruction manual.
Declaration of conformity.
FEIN declares itself solely responsible for this product conforming with the
relevant provisions given on the last page of this Instruction Manual.
Technical documents at: C. & E. Fein GmbH, 73529 Schwäbisch Gmünd-Bargau
Environmental protection, disposal.
Packaging, worn out machines and accessories should be sorted for environment-
friendly recycling.
China RoHS Status Certificate
Table of Toxic and Hazardous Substances/Elements and their Content as required by China’s Management Methods for Controlling Pollution by Electronic Information Products
| Hazardous substance
---|---
Component name| (Pb)| (Hg)| (Cd)| (VI))| (PBB)| (PBDE)
Electronics (PCB,switch, wiring etc.)| x| o| x| o| o| o
Motor| x| o| o| o| o| o
Power cord| x| o| o| o| o| o
Fastener elements| x| o| o| o| o| o
Metal parts| x| o| o| o| o| o
Power supplies| x| o| o| o| o| o
Brass parts| x| o| o| o| o| o
Aluminium parts| x| o| o| o| o| o
This table was developed according to the provisions of SJ/T 11364.O: The
content of such hazardous substance in all homogeneous materials of such
component is below the limit required by GB/T 26572X: the content of such
hazardous substance in a certain homogeneous material of such component is
beyond the limit required by GB/T 26572
C. & E. Fein GmbH
Hans-Fein-Straße 81
73529 Schwäbisch Gmünd-Bargau, Germany
www.fein.com
References
Read User Manual Online (PDF format)