legrand-ZLGP14-Home-Away-Control-Product

Requires to install the connected starter pack and one or more «… with Netatmo» connected switch, micro module or socket outlet.

Overview

  • Module Control
  • Gateway power outlet and home/away wireless master switch
  • Mobile gateway power outletlegrand-ZLGP14-Home-Away-Control-Fig- 8

Pack contents

legrand-ZLGP14-Home-Away-Control-Fig- \(1\)

Installation

Start the configuration
Press the configuration button of Module Control or press the middle of the wireless master switch (with battery) or on the configuration button of the mobile gateway power outlet until its light briefly turns green, and then stop
pressing. All wired product lights will turn green.

legrand-ZLGP14-Home-Away-Control-Fig- \(2\)

Pair the wireless, batteryless switch to your connected installation.
Make sure that the indicator lights on the wired products are green and not flashing. If not, go back to step 1.

legrand-ZLGP14-Home-Away-Control-Fig- \(3\)

  • A1
    Tap 3 times any wired product “with Netatmo” with the wireless, batteryless “Home/Away control”. The light of the wired product flashes rapidly.

  • A2
    For the specific case of the latching relay, press the main button of the latching relay until the configuration indicator flashes slowly in blue, release it then tap it 3 times with the wireless, batteryless “Home/Away control”. The indicator light of the wired product flashes rapidly.

  • B.
    While holding the “setup” button on the wireless, batteryless control, briefly press the “Home” or “Away” control on the wireless batteryless control.

  • C.
    The indicator light of the wired product will briefly turn blue and then will turn green again. The pairing was successful.

Complete the configuration of the scenarios using your HOME + CONTROL application, menu “Settings”, then “Scenarios”.

Complete the installation

  • To complete your installation, briefly press the configuration of the Module Control or the middle of the wireless Home / Away master switch or on the configuration button of the mobile gateway power outlet.
  • All the indicator lights on the products switch off

If necessary, erase the configuration of the wireless batteryless control (factory reset)

  • While holding the “setup” button on the wireless batteryless control, press the “Home” button for 5 seconds.
  • Confirm that your control is correctly reset by making a “Home” command, then “Away”

Before fixing the wireless control(s) with the removable stickers provided, test one on a non-visible area of the wall.

legrand-ZLGP14-Home-Away-Control-Fig- \(6\)

You can also fix the wireless control(s) permanently to the wall with screws.

www.legrandoc.com/064872L
LEGRAND – Pro and Consumer Service – BP 30076 87002 LIMOGES CEDEX FRANCE • www.legrand.com.

The undersigned, Legrand declares that the radio-electric equipment type (0 648 72L/73L – 0 677 85L – 5 744 30/31/32/33 – CB0422/CT0422/CN0422 – 0 770 56L – 6 000 85L – 7 418 01L/31L/61L) complies with directive
2014/53/EU. The full text of the EU Declaration of Conformity is available on the following website: www.legrandoc.com.

Download the app

Your installation is ready. You can download the Legrand Home + Control application to control your lights remotely.

FCC STATEMENT

  • FCC ID: 2ACN8-ZLGP1X
  • IC: 12132A-ZLGP1X
  • Model: ZLGP14

This device contains licence-exempt transmitter(s)/receiver(s) that comply with FCC RF and Innovation, Science and Economic Development Canada’s licence- exempt RSS(s).

Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

This device complies with FCC and ISED radiation exposure limits set forth for the general population. This device must not be co-located or operating in conjunction with any other antenna or transmitter.

FCC Caution:
The user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Safety instructions
Make sure the power supply is disconnected before any intervention. Strictly comply with instructions for installation and use.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals