HOCHIKI FNV-MP High Rise Voice Evacuation System Master Panel Instruction Manual
- June 9, 2024
- HOCHIKI
Table of Contents
HOCHIKI FNV-MP High Rise Voice Evacuation System Master Panel
Features
- True Multiplex 6 Channel Distributed Audio
- Integrated Fire Phone, Area of Rescue and Fan & Damper Control capability
- Modular System – components added as needed
- Integrated 2 Channel Digital Message Repeater
- Live Microphone Page to any zone
- Fast RS-485 Communication Protocol
- Fully Supervised
- Easy Installation and Operation
- Natural Sound Voice Recordings
- Built in Alarm and Alert Signals
- Up to 4 Minute Message Capacity
- Works with 12VDC or 24VDC Fire Alarm Panel
- Works with Analog/Addressable and Microprocessor based Fire Alarm Panels.
- 3 Minute Message Restart on Microphone Key
- Made in the USA.
Description
The Hochiki FNV High Rise Evacuation System operates in conjunction with the Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies. The Hochiki FNV includes all necessary features to provide an effective voice evacuation system. The Hochiki FNV can be custom configured to satisfy the needs of any high rise application. Fire department authorities can easily take command of evacuation or relocation procedures and emergencies. Building management and fire brigades can monitor and control emergency response even before the professionals arrive
The FNV system includes capacity for 6 channels of simultaneous audio. This provides for evacuation, stay-in-place, or other public address announcements and automatic messages. Fire Fighter Phones or Warden Stations may be included as required. Area-of-Rescue stations can reassure handicapped occupants that help is on the way. Smoke control, stair pressurization, and HVAC shutdown can be completely automatic, unless controlled manually by management or fire authorities.
System Configuration
Basic System Includes
- Master Panel (FNV-MP)
- Master Mic Control
- 16 Switch Control points
- Dual Channel DMR
- High Speed communication loop
Optional
- Integrated Master Fire Phone
- Area-of-Rescue
- Fan and Damper system control
- Maximum System Configuration
- Up to 1000 monitor and control points
Ribbon Cable Connection Detail
In the Master Panel system components are mounted to a removable back plate. The door and front panel are removable. This enables field wiring to be installed cleanly. Connections to the User Interface components ( Switch/LED banks, Mic/System control and Master Fire Phone) is accomplished with ribbon cables. The front panel mounts separately on a continuous hinge so once installed the access for system programming is easily accommodated.
NetComm Loop Wiring (Style 4)
NetComm Loop Wiring (Style 7)
The redundant loop must be run in separate conduit with minimum spacing from the primary. Check local code requirements.
Master Panel Configurations
- FNV-MP16: Master Panel, 16 Switch Control
- FNV-MP32: Master Panel, 32 Switch Control
- FNV-MP48: Master Panel, 48 Switch Control
- FNV-MP64: Master Panel, 64 Switch Control
- FNV-MP80: Master Panel, 80 Switch Control
- FNV-MP96: Master Panel, 96 Switch Control
- FNV-MP16/P: Master Panel, 16 Switch Control, Master Fire Phone
- FNV-MP32/P: Master Panel, 32 Switch Control, Master Fire Phone
- FNV-MP48/P: Master Panel, 48 Switch Control, Master Fire Phone
- FNV-MP64/P: Master Panel, 64 Switch Control, Master Fire Phone
- FNV-MP80/P: Master Panel, 80 Switch Control, Master Fire Phone
- FNV-MP96/P: Master Panel, 96 Switch Control, Master Fire Phone
Panel Options
Cards may be added as job requirements demand
- FNV-MFP Master Fire Phone: Enables system to incorporate 2 way communication.
- Included with /P panels.
- FNV-SSC Switch Scan Card: Included in basic panels, up to 7 additional cards may be added.
- FNV-SLC Switch LED Card: 16 Switch LED Bank, up to 8 per FNV-SSC.
- FNV-IOI Input Interface Card: One included with basic panel, additional cards give 16 control
Technical Characteristics
- Primary Power: 120 VAC
- 24 VDC Battery Power
- Electrical Ratings: All Circuits @ 24VDC.
Master Panel /Standby /Alarm
- DCC: 80 mA/ 80 mA
- ASC: 30 mA/ 30 mA
- MFP: 10 mA/ 10 mA
- SSC: 25 mA/ 25 mA
- SLC: 6 mA/ 6 mA
- MMC: 45 mA/ 45 mA
- IOI: 20 mA/ 20 mA
- Communications Bus: RS-485 Standard, 1M Baud data rate, Category 5 cable.
- Voltage: 5V peak-to-peak max.
- Current: 50mA max.
- Impedance: 120 Ohms (max. imp. between panels)
- Frequency: 1.024MHz
- Backbox Dim: 14.5 x 27 x 4“ w h d
- Color: Charcoal Grey standard Red optional
Specifications are subject to change without notice. Specifications are provided for information only and no responsibility is assumed by Hochiki America, Inc. for their use.
CONTACT
- 7051 Village Drive, Suite 100 Buena Park, CA
- 90621-2268
- 714.522.2246
- www.hochiki.com
References
- Fire Alarm Resources | Download fire alarm documents
- Hochiki | Fire Protection Equipment and Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>