HOCHIKI FNV-DP High Rise Voice Evacuation System Instruction Manual
- June 9, 2024
- HOCHIKI
Table of Contents
HOCHIKI FNV-DP High Rise Voice Evacuation System
Features
- True Multiplex 6 Channel Distributed Audio
- Integrated Fire Phone, Area of Rescue and Fan & Damper Control capability
- Modular System – components added as needed
- Integrated 2 Channel Digital Message Repeater
- Live Microphone Page to any zone
- Fast RS-485 Communication Protocol
- Fully Supervised
- Easy Installation and Operation
- Natural Sound Voice Recordings
- Built in Alarm and Alert Signals
- Up to 4 Minute Message Capacity
- Works with 12VDC or 24VDC Fire Alarm Panel
- Works with Analog/Addressable and Microprocessor based Fire Alarm Panels.
- 3 Minute Message Restart on Microphone Key
- Made in the USA.
Description
The Hochiki FNV High Rise Evacuation System operates in conjunction with the Fire Alarm Control Panel (FACP) in a building to provide automatic response to life safety emergencies.
The Hochiki FNV includes all necessary features to provide an effective voice evacuation system. The Hochiki FNV can be custom configured to satisfy the needs of any high rise application. Fire department authorities can easily take command of evacuation or relocation procedures and emergencies. Building management and fire brigades can monitor and control emergency response even before the professionals arrive
The FNV system includes capacity for 6 channels of simultaneous audio. This provides for evacuation, stay-in-place, or other public address announcements and automatic messages. Fire Fighter Phones or Warden Stations may be included as required. Area-of-Rescue stations can reassure handicapped occupants that help is on the way. Smoke control, stair pressurization, and HVAC shutdown can be completely automatic unless controlled manually by management or fire authorities.
System Configuration
Basic System Includes
- Distributed Panel (FNV-DP)
- 4 Output Zones (may be configured for 8)
- Dual Channel Audio Interface
- Dual/Single Channel Amplification
Amplifier Options
- 25 / 50 / 100W Dual Channel
- 25 / 50 / 100 / 200W Single Channel
Optional
- Integrated Fire Phone
- 4 Circuits expandable to 8 or 12
- Area-of-Rescue
- Fan and Damper system control
- Maximum System Configuration
- Up to 256 Distributed Panels (FNV-DP)
Distributed Panel Connection Detail
FPI to MBR Connection
- Each FNV-DP panel may have up to 4 FPI cards for a max. of 16 phone circuits.
- (Additional FPI cards require an FNV-FPO for circuit termination)
AMI to Amplifier Connection
- Each AMI card provides audio channels and control to two amplifier modules or amplifier banks. Maximum configuration is 5 AMI cards in each FNV-DP.
- (Additional modules would mount in separate cabinets)
Eight Class “B” Speaker Lines
- Eight Class “B” may also be configured as 4 A / B circuits.
Four Class “A” Speaker Lines
Distributed Panel Configurations
- FNV-DPS25: Distributed Panel, Single Channel, 25W
- FNV-DPS50: Distributed Panel, Single Channel, 50W
- FNV-DPS100: Distributed Panel, Single Channel, 100W
- FNV-DPS25/P: Distributed Panel, Single Channel, 25W, Fire Phone
- FNV-DPS50/P: Distributed Panel, Single Channel, 50W, Fire Phone
- FNV-DPS100/P: Distributed Panel, Single Channel, 100W, Fire Phone
- FNV-DP25: Distributed Panel, Dual Channel, 25W
- FNV-DP50: Distributed Panel, Dual Channel, 50W
- FNV-DP100: Distributed Panel, Dual Channel, 100W
- FNV-DP25/P: Distributed Panel, Dual Channel, 25W, Fire Phone
- FNV-DP50/P: Distributed Panel, Dual Channel, 50W, Fire Phone
- FNV-DP100/P: Distributed Panel, Dual Channel, 100W, Fire Phone
Panel Options
Cards may be added as job requirements demand
- FNV-MBK Motherboard Relay Card: Expands MBR output 8 Class B or 4 Class A speaker circuits
- FNV-FPI Fire Phone Interface Card: Included in /P panels, up to 3 additional cards may be added
- FNV-FPO Fire Phone Output Card: Used with additional FNV-FPIs for termination
- FNV-AMI Audio Module Interface Card: Included with basic panel, additional cards give the ability to control multiple modules or accommodate full 3 channel operation
Technical Characteristics
- Primary Power: 120 VAC
- 24 VDC Battery Power
- Electrical Ratings: All Circuits @ 24VDC.
Distributed Panel/ Standby /Alarm
- DCC: 55 mA/ 55 mA
- MBR: 10 mA/ 55 mA
- AMI: 10 mA/ 10 mA
- FPI: 13 mA/ 13 mA
_ Battery Charging: _Maximum charging current from
- FNV-25/50 is 800mA. Maximum battery size is 17AHr.
- FNV-100 Maximum battery size is 24AHr.
- Communications Bus: RS-485 Standard, 1M Baud data rate, Category 5 cable.
- Voltage: 5V peak-to-peak max.
- Current: 50mA max.
- Impedance: 120 Ohms (max. imp. between panels)
- Frequency: 1.024MHz
- Backbox Dim: 14.5 x 27 x 4“ w h d
- Color: Charcoal Grey std Red optional
Specifications are subject to change without notice. Specifications are provided for information only and no responsibility is assumed by Hochiki America, Inc. for their use.
Contact
- 7051 Village Drive, Suite 100 Buena Park, CA
- 90621-2268
- 714.522.2246
- www.hochiki.com
References
- Fire Alarm Resources | Download fire alarm documents
- Hochiki | Fire Protection Equipment and Systems