03 Power On

Step 1 Power on the inverter.
Step 2 Power on the router.
Step 3 Check communication status of the Ezlink through indicators.
Note: Check the indicators on the Ezlink and the inverter to confirm the communication
status of the device.

Indicator/Silkscreen

|

Color

|

Status

|

Description

---|---|---|---

|

Blue

|

Blink

|

The Ezlink is working properly.

OFF

|

The inverter is powered off.

|

Green

|

ON

|

The Ezlink is connected to the server.

Blink 2

|

The Ezlink is not connected to the router.

Blink 4

|

The router is not connect to the internet.

RELOAD

|

|

|

Short press to restart the Ezlink.

Long press for 5 seconds to restore factory  settings.

04 Commissioning via SolarGo App

Step 1 Download and install SolarGo app.
The UI may be different due to the app version
upgrade. Scan the QR code for latest SolarGo app user
manual.

Step 2 Connect the app and the device.

connecting apps

parallel systemStep 3 (Optional) When multiple inverters are parallel connected,
scan the QR code or click Parallel Inverter System Solution User
Manual for more details.

Step 4 Set communication settings of the device.
• The interface may differ depending on the communication method.
• Make sure that the WiFi RSSI value is higher than -60, -50 or higher is recommended.
When the RSSI value is less than -60, you should move the router closer to the device,
remove the obstacle, or add a repeater to improve the signal strength.

No.

|

Name

|

Description

---|---|---

1

|

WiFi Network

|

Select WiFi based on the actual connecting.

2

|

Password

|

WiFi password for the actual connected network.

3

|

DHCP

|

• Enable DHCP when the router is in dynamic IP mode. • Disable DHCP when a switch is used or when the router is  in static IP mode.

4

|

IP Address

|

• Do not configure the parameters when DHCP is enabled. • Configure the parameters according to the router or  switch information when DHCP is disabled.

5

|

Subnet Mask

6

|

Gateway Address

7

|

DNS Server

05 Device Replacement

Step 1 Prepare a new device before replacing the old Ezlink.

Step 2 Remove the Ezlink using the Unlock Tool.

Step 3 Install the new device.

Step 4 Refer to the Quick Installation Guide to configure the new device.

06 Troubleshooting

No.

|

Problem

|

Solutions

---|---|---

1

|

Cannot find CCM

BLE**

|

1. Make sure that the inverter is powered on and the Ezlink  device is connected properly.

2. Make sure that the smart device is within the  communication range of the Ezlink device.

3. Restart the inverter or short press to restart the Ezlink.

2

|

Unable to connect to  CCM-BLE**

|

1. Make sure that no other smart device is connected to  CCM-BLE**.

2. Restart the inverter or short press to restart the Ezlink,  then reconnect CCM-BLE**.

3

|

 Indicator double

blink

|

1. Make sure that the router is powered on.

2. Make sure that the LAN cable is connected tightly.

Quick Installation Guide V1.1-2022-12-30

4

|

 Indicator

quadruple blink

|

1. Make sure that the cables are connected properly, and  the router can access the internet.

2. If the problem persists, contact the after sales service.

---|---|---

5

|

 Indicator off

|

Check whether the inverter is powered on.

07 Technical Data

Model

|

Ezlink3000

---|---

General

Parameters

|

Connection Interface

|

USB

Ethernet Interface (Optional)

|

10/100Mbps self-adaption,

Communcation distance ≤100m

Bluetooth

|

Bluetooth 5.1

Installation

|

Plug-and-play

Indicator

|

LED Indicator

Dimensions (W × H ×D mm)

|

153 × 49 × 32

Weight (g)

|

130

Ingress Protection Rating

|

IP65

Power Consumption (W)

|

≤2

Operation Mode

|

STA

Wireless

Parameters

|

WiFi Communication

|

802.11 b/g/n(2.412GHz-2.484GHz)

Environment

Parameters

|

Operating Temperature Range (°C)

|

 -30 ~ +60

Storage Temperature Range (°C)

|

 -30 ~ +70

Relative Humidity (non

condensing)

|

0-100%

Max. Operating Altitude (m)

|

4000

For more information, scan the QR codes below.

SolarGo App SolarGo User  Manual

SEMS Portal App

SEMS Portal app  User Manual

Parallel Inverter  System Solution  User Manual

Website

GoodWe Technologies Co., Ltd.

No. 90 Zijin Rd., New District, Suzhou, 215011, China

www.goodwe.com

service@goodwe.com 340-00647-01 Local Contacts

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals