Roper Rhodes TR9016 Touch Sensor Dual Flush Plate Installation Guide

June 1, 2024
ROPER RHODES

Roper Rhodes TR9016 Touch Sensor Dual Flush Plate

Roper-Rhodes-TR9016-Touch-Sensor-Dual-Flush-Plate-product-
image

Touch Sensor Dual Flush Plate
Specifications :

  • Compatible with wall-hung frame cisterns and In-wall cisterns from Roper Rhodes Group
  • Minimum depth for in-wall installation: 15.5mm
  • Requires 4x AA batteries (not included)
  • Three finger activation for sensor

Product Usage Instructions

Battery Installation:

  1. Open the glass plate by pushing it towards the top and tilting it forwards.
  2. Insert 4x AA batteries into the battery compartment, noting the polarity.
  3. Slide the battery holder back into place and replace the glass fascia.
  4. LEDs will illuminate, indicating readiness for use.

Installation :

  1. Cut the protective casing of the in-wall cistern in-line with the finished wall surface.
  2. Screw the fixing arms onto the cistern, adjusting rod length as needed.
  3. Connect air hoses from cistern to flush plate (blue hose to half moon symbol, transparent hose to full moon symbol).
  4. Mount the bracket onto fixing arms and secure with screws.
  5. Reconnect clip links and cable ribbon to the glass fascia.
  6. Insert battery holder and test functionality after removing protective film.

Operation :

  • Three Finger Activation: Touch the sensor with a minimum of three fingers for two seconds to activate.
  • Full / Reduced Flush: Automatically adjusted based on sensor input.
  • Manual Over-ride: In case of exhausted batteries, remove glass fascia to access manual flush button.

FAQ :

  • Q: How long do the batteries typically last?
    A: Good quality alkaline batteries should last for approximately one year under normal domestic conditions.

  • Q: How do I know when to replace the batteries?
    A: An alarm will sound continuously for 10 seconds when batteries need replacement. Additionally, LED lights will flash when batteries are low.

Touch Sensor Dual Flush Plate
Installation & Operation Instructions
Please read completely before commencing. Retain for future reference

Introduction

  • This sensor flush plate is compatible with wall hung frame cisterns and In-wall cisterns from Roper Rhodes Group.
  • For In-wall installation the front of frame to front of finished wall minimum depth should be 15.5mm.
  • If used with a furniture concealed cistern ensure a clearance of 105mm is left between the cistern and the front of the furniture fascia surface to allow adequate installation.

Battery Installation (Batteries not included)

  • Open the glass plate by pushing it towards the top and then tilting it forwards. The clip chain will allow it to hang, make sure it’s secured before dropping it.Roper-Rhodes-TR9016-Touch-Sensor-Dual-Flush-Plate- \(2\)
  • Remove the battery holder and insert 4x AA batteries into the battery compartment, noting the polarity on the battery holder. Slide back into place and replace the glass fascia. The LEDs will Illuminate, indicating that the flush plate is ready to be used.
  • Good quality Alkaline batteries will last for approximately one year in normal domestic conditions.
  • Once batteries are due to be replaced, a continuous alarm will be heard for 10s, indicating that battery power is low and that they are due to be changed. The LED lights will also flash.
  • Batteries are totally exhausted when the LED lights are continuously flashing (twice per second). Please replace the batteries immediately.
  • A manual over-ride button is available if batteries are totally exhaust-ed. Roper-Rhodes-TR9016-Touch-Sensor-Dual-Flush-Plate- \(3\)

Installation

  1.  Cut the protective casing of the in-wall cistern in-line with the finished wall surface.

  2. Screw the fixing arms (supplied in the box) onto the cistern.
    The rods may need cutting down depending on the thickness of the finished wall/surface.

  3. Remove the front fascia panel completely. Push the glass front to the top and tilt the top towards you. Un-clip the glass fascia by expanding the clip links and keep aside until installation is completed. Remove the battery holder also to avoid damage.

  4.  Connect the air hoses from the cistern to the flush plate as shown. Attach the blue hose to the half moon symbol and the transparent hose to the full moon symbol.

  5. Make sure the cistern is fully commissioned before mounting the bracket in place.

Locate the mounting bracket onto the fixing arms and secure the top left and bottom right corners with the screws provided and tighten with a screwdriver. Be careful not to overtighten.

Roper-Rhodes-TR9016-Touch-Sensor-Dual-Flush-Plate-
\(9\)Re-connect the clip links and cable ribbon to the glass fascia and insert the battery holder. Place the front glass plate and remove the protective film prior to testing its functioning. Once correctly attached the flush plate will illuminate for a couple of seconds.

Operation

Three Finger Activation: Use a minimum of three fingers touching the sensor for two seconds to activate.

Full / Reduced Flush

  • Full Flush : Touch the longer decal side with three fingers for two seconds to activate the flush. The LED lights will Illuminate.
  • Reduced Flush : Touch the shorter decal side with three fingers for two seconds to activate the flush. The LED lights will Illuminate.

If the flush plate is touched for more than 5 seconds and still won’t flush, please refer to the ‘Troubleshoot’ document.

Manual over-ride

  • If batteries are exhausted completely, the glass fascia can be removed to reveal the manual flush button.
  • The manual over-ride is not intended as a long term solution. When using the manual push button, un-plug the cable ribbon and take the front glass fascia off the chain links. Keep safe to prevent damage.

Specification

  • Batteries: 4x AA (LR6) Alkaline Batteries (Not supplied)
  • Ingress Protection: IPX4
  • At the end of life, please dispose of batteries and unit where municipal recycling facilities exist. Do not dispose of in the regular waste.

Roper-Rhodes-TR9016-Touch-Sensor-Dual-Flush-Plate-
\(13\)

  • Brought to you by the Roper Rhodes Group Brassmill Lane Trading Estate
  • Bath
  • BA1 3JF
  • t: 01225 303900

Troubleshooting guide

Problem Potential cause Suggested action
There is still water coming into the pan after the flush should have stopped.
Hoses are inhibiting the operation of the valve. Make sure hoses go around

the valve instead of over it, ensuring the flush valve is free to move.
The cistern is not filling up.| The isolation valve hasn’t been opened.| Make sure the flush valve is working and the inlet valve is filling up the cistern.

  • The alarm is sounding every 2 seconds and the LED’s are flash- ing.
  • No flush happens.

| Batteries are completely exhausted.|

  • The battery power is too low for flush operation. Open the compartment and replace the batteries on the battery holder for new ones.

  • Good quality Alkaline batteries will last for approximately one year in normal domestic conditions.

  • The alarm is sounding every for 10 seconds and the LED’s flash 10 times.

  • It can still flush however.

| Battery power is low.| The batteries are starting to run out. Please replace as soon as possible.

The Touch Sensor is not working.|

  • Battery power is low.
  • Batteries not inserted correctly. Battery compartment not aligned correctly.
  • Not using the 3 finger activation system.

| The batteries are starting to run out. Please replace as soon as possible. Make sure the batteries and compartment are correctly inserted and aligned. Refer to the instructions for the 3 finger activation system information

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ROPER RHODES User Manuals

Related Manuals