Specifications

  • Model: TR9014
  • Compatibility: Pneumatic concealed cisterns from Roper Rhodes Group
  • Power Source: 4x AA Batteries (not supplied)
  • Battery Life: Approximately one year in normal domestic conditions
  • Technology: Capacitive sensor technology

Installation Instructions

  1. Locate the desired position for the sensor ensuring ample space for orientation.
  2. Connect air hoses from the cistern to the sensor body (blue hose to half moon, transparent hose to full moon).
  3. Mount the sensor behind the front fascia or under the worktop using self-tapping screws.
  4. Attach the sensor decal or colored button to indicate sensor location.

Operation Instructions

To trigger a short flush:

  • Wave your hand in front of the sensor location.
  • You will hear one beep from the sensor indicating the short flush has been activated.

FAQ

  • How long do the batteries last?
    The alkaline batteries will last for approximately one year under normal domestic conditions.

Contactless Dual Flush Sensor

Installation & Operation Instructions – For Domestic Use Only
Please read completely before commencing. Retain for future reference

Introduction

This contactless flush sensor kit is compatible with pneumatic concealed cisterns from Roper Rhodes Group. It is intended to replace the flush button supplied with concealed cisterns.
The sensor works using capacitive sensor technology to sense a change in the electromagnetic field when the user waves their hand in front of the sensor. The sensor can be mounted behind a furniture fascia or tiled wall where the cistern is located. A choice of small decals or a chrome button are included to stick on the front of a fascia or tiled surface to indicate sensor location.

Contents

Roper-Rhodes-Group-TR9014-Battery-Powered-Dual-Flush-Contactless-
Button-Kit- \(2\)Battery Installation

Open the lid and slide out the battery holder by flipping the tab on the front of the sensor body. Insert 4x AA batteries into the battery compartment, noting the polarity on the battery holder. Slide back into place and click the lid shut. A double beep from the unit indicates that the sensor is activated.

Roper-Rhodes-Group-TR9014-Battery-Powered-Dual-Flush-Contactless-Button-Kit-
\(3\)Good quality Alkaline batteries will last for approximately one year in normal domestic conditions.
Once batteries are exhausted, a continuous alarm will be heard, indicating that battery power is low and that they are due to be changed.

Installation

  1. Locate the desired position for the sensor. Make sure that there is ample space for the chosen orientation of the sensor unit.
    Roper-Rhodes-Group-TR9014-Battery-Powered-Dual-Flush-Contactless-Button-Kit-
\(4\)
    The unit can be mounted behind the front fascia or under the worktop of a WC furniture unit. Make a suitable pilot hole and use the self tapping screws supplied if mounting onto a wooden fascia.
    If using with a wall hung frame, in lieu of a flush plate, or in a tiled in installation, please ensure that there is still ample service access to the cistern tank.

  2. Connect the air hoses from the cistern to the sensor body as shown. Connect the blue hose to the half moon symbol and the transparent hose to the full moon symbol.
    Roper-Rhodes-Group-TR9014-Battery-Powered-Dual-Flush-Contactless-Button-Kit-
\(5\)

  3. Click the sensor body into place on the mounting bracket, aligning as shown below. Then attach worktop or fascia according to the instructions supplied with the WC furniture unit.
    Roper-Rhodes-Group-TR9014-Battery-Powered-Dual-Flush-Contactless-Button-Kit-
\(6\)

  4. Apply the sensor decal or coloured button to either the top or front fascia of the unit depending on the orientation of the sensor. This is to act as an indicator that there is a sensor used inside the furniture.
    It must be stuck on the reverse side to where the bracket is mounted.

Operation

Short Flush: A quick wave of the hand in front of the sensor location will operate the short flush of the pneumatic cistern. The user will hear one beep of the sensor.
Full Flush: The user should hold their hand for approximately 2 seconds in front of the sensor location in order to operate the full flush function of the cistern. The user will hear two beeps of the sensor.

Please note the effective range of the sensor can vary depending on the substrate on which it is mounted (see specification, right).
Important – Do not place metallic items over the top or immediately in front of the sensor as this will impair performance.

Specification

Batteries: 4x AA (LR6) Alkaline Batteries (Not supplied)

Working range

  • Wooden Fascia (up to 25mm thickness) 25±5mm
  • Laminate Worktop (up to 28mm thickness) 20±5mm
  • Solid Surface Worktop (25mm thickness) 30±5mm
  • Tile on Plasterboard (up to 35mm thickness) 20±5mm
  • Power: 3W
  • Voltage: 6V
  • Ref: D32-J205-01

At the end of life, please dispose of batteries and unit where municipal recycling facilities exist. Do not dispose of in the regular waste.
This product is only suitable for domestic use.