aldes T.Flow Thermodynamic Water Heater User Guide
- June 12, 2024
- aldes
Table of Contents
- Congratulations!
- Standards and regulations
- Description
- SELECT YOUR MODE
- ADJUSTING YOUR DAILY QUANTITY OF HOT WATER
- MONITORING ELECTRICAL CONSUMPTION AND RESETTING (FILTER)
- REPLACING YOUR FILTER
- YOU HAVE THE CONNECTED VERSION (WITH MODEM)?
- Customer Service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
aldes T.Flow Thermodynamic Water Heater
Congratulations!
Congratulations, your dwelling is fitted with a T.Flow® Hygro+ or a T.Flow®
Nano!
As ventilation specialist, Aldes has successfully reconciled air quality and
domestic hot water.
The T.Flow® Hygro+/T.Flow® Nano systems use the calories from the air
extracted from your dwelling – a free, inexhaustible energy source – to heat
your domestic water.
The entire family thus enjoys healthy air and hot water throughout the year at
minimum cost.
Increased savings
T.Flow® produces up to 73% hot water free of charge.
More comfort
T.Flow® Hygro+ / T.Flow® Nano range easily covers the domestic hot water
requirements of a family up to 6 people.
More control
AldesConnect TM can be used to monitor and manage your domestic hot water
production in real time, directly from a smartphone.
Improved air quality
Thanks to its ventilation function, the air within the dwelling is constantly
renewed, providing a healthier environment.
More discretion
The T.Flow® Hygro+ connected is the quietest(2) and slimmest unit in its
class, designed to be built into a standard cupboard or laundry room.
Standards and regulations
B200-FAN_T.Flow® Hygro+ (11023198)
B200 T.Flow® Hygro+ (11023199)
B100-FAN _T.Flow® Nano (11023394)
B100 T.Flow® Nano (11023395)
B200-FAN_T.Flow® Hygro+ (with built-in fan – 11023198) and
B100-FAN_T.Flow® Nano (with built-in fan – 11023394):
French CSTB Technical Report no. 14.5/17-2266 and certification QB
70/02-CHY5-2266
B200_T.Flow® Hygro+ (without fan) and B100_T.Flow® Nano (without fan): French CSTB Technical Report no. 14.5/17-2267
T.Flow® Hygro+ / T.Flow® Nano have a fluorinated greenhouse gas contained
within a hermetically-sealed unit.
Refrigerant R513a (PRG: 631).
T.Flow® Hygro+: initial load of 650 g i.e. 0.41 tCO2eq.
T.Flow® Nano: initial load of 580 g i.e. 0.37 tCO2eq.
- COP at 20°C at maximum airflow (222,8 m3/h) of T.Flow® for Individual Houses.
- Multi-occupancy housing version: less than 21 dB(A) – Max. value at 150 m3/h, Lp at 2 m in free air
-
Complies with eco-design regulation 814/2013 and energy labelling regulation 812/2014 for domestic hot water.
Complies with eco-design regulation 1253/2014 and energy labelling regulation 1254/2014 for ventilation -
Energy class – ventilation
-
Energy class – domestic hot water
Description
- A T.Flow® Hygro+/T.Flow® Nano
- B Filter access hatch
- C G4 filter*
- D Aldes ConnectTM app (connected version)
- E Alde sConnectTM Box (connected version)
-
Filter class G4 as per EN 779 and ISO Coarse 65% as per ISO 16890.
- F Active elements running: heat pump ON heating element ON
- G Modes: Auto – Boost – Comfort/Guests – Holidays
- H Selection – Configuration – Navigation
- I Anti-Legionella option ON
- J Filter clogging Indicator (Example opposite: 75%)
- K Hot water temperature setpoint
- L Quantity of hot water available (Example opposite: 66%)
SELECT YOUR MODE
The mode is used to adjust your hot water production:
- Automatically (1.1)
- Occasionally:
- Boost (1.2)
- Comfort/Guests (1.3)
- Holidays (1.4)
Auto Mode (default)
“I set my temperature setpoint and the water heater controls the production
automatically.”
Boost Mode
“I need hot water urgently!”
The product then moves automatically into Auto mode once the setpoint is reached.
Comfort/Guests Mode
“My guests are arriving! I need more hot water for one or more days.”
Holiday Mode
“I wish to pause heating my water during my holidays! The ventilation
continues to protect my dwelling.”
Hot water production is reactivated one day before halting the mode, so that hot water is available on your return.
ADJUSTING YOUR DAILY QUANTITY OF HOT WATER
- To save on hot water production, set a temperature setpoint of less than 55°C.
- For more hot water, increase the temperature setpoint.
T.Flow® Hygro+
Temperature setpoint| Nbr. of people
45 to 48°C.| 2-3
48.5 to 50°C.| 4-5
50.5 to 53.5°C.| 5-6
54 to 57.5°C.| 6-7
58 to 65°C.| 7-8
T.Flow® Nano
Temperature setpoint| Nbr. of people
50°C| 1+
50.5 to 53°C.| 2
53.5 to 59°C.| 2+
59.5 to 65°C.| 3
These settings are given as a guide only. As use profiles are specific, do not hesitate to fine tune the setting to find the optimum for your daily requirement and your energy saving goals.
MONITORING ELECTRICAL CONSUMPTION AND RESETTING (FILTER)
REPLACING YOUR FILTER
When the filter is full, a “filter full” alarm appears on the screen and the
backlighting remains lit.
It is advisable to change the filter at least once a year.
CAUTION: It is essential to reset when changing the filter.
YOU HAVE THE CONNECTED VERSION (WITH MODEM)?
- Download the AldesConnectTM app now
- Connect your modem
- Real-time monitoring
- Notifications
- 4 programming modes
- Personalised advice
YOU DO NOT HAVE THE CONNECTED VERSION?
- Order your AldesConnectTM Box onwww.aldes.fr now
- Connect your water heater simply and quickly
Customer Service
www.aldes.com
20, boulevard Irène Joliot-Curie 69694 Vénissieux Cedex – France
References
- Aldes, Ventilation et Confort Thermique
- EXHAUSTO by aldes GmbH | Ihr Experte für Raumluftqualität
- Solutions traitement de l'air La qualité d'air intérieur | Aldes, traitement de l'air intérieur
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>