tp-link TL-SM321A-2 1000Base-BX WDM Bi-Directional SFP Module Installation Guide

October 30, 2023
tp-link

tp-link-logo

tp-link TL-SM321A-2 1000Base-BX WDM Bi-Directional SFP Module

Product Information

The 1000Base-BX WDM Bi-Directional SFP Module is a high-performance and cost- effective device designed for optical communication applications. It supports data rates of up to 1.25 Gbps and has a transmission distance of up to 20 km. The module comes with two different models, TL-SM321A and TL-SM321B, with different normal wave lengths and maximum cable lengths. The SFP module is hot-swappable and can be easily installed or removed without shutting down the system.

Specifications

| TL-SM321A| TL-SM321B
---|---|---
Normal Wave Length| Tx: 1550 nm Rx: 1310 nm| Tx: 1310 nm Rx: 1550 nm
Standards and Protocols| IEEE 802.3z, TCP/IP| IEEE 802.3z, TCP/IP
Cable Fiber Type| Single-mode Fiber| Single-mode Fiber
Max. Cable Length| 20 km| 2 km
Data Rate| 1.25 Gbps| 1.25 Gbps
Port Type| LC Simplex| LC Simplex
Power Support| 3.3 V| 3.3 V
Safety & Emission| FCC, CE| FCC, CE
DDM| Yes| Yes
SFP-MSA| Yes| Yes
Hot Swappable| Yes| Yes

Environmental and Physical Specifications:

  • Storage Temperature: -40°C to 85°C
  • Operating Temperature: 0°C to 70°C
  • Operating Humidity: 10% to 90% RH, Non-condensing
  • Storage Humidity: 5% to 90% RH, Non-condensing

TP-Link Compatible Products:
The SFP module is compatible with TP-Link switches with gigabit SFP slots, such as MC220L. Please note that the SFP module may be incompatible with other vendors’ devices. It is recommended to use only TP-Link SFP modules on TP-Link devices.

FCC Compliance Information Statement
The 1000Base-BX WDM Bi-Directional SFP Module complies with part 15 of the FCC Rules and is properly maintained and operated. Any changes or modifications not expressly approved by the party  for compliance could void the user’s authority to operate the equipment.

Product Usage Instructions

To install the SFP module, follow these steps:

  1. Wear an ESD-preventive wrist or ankle strap to prevent ESD damage to the transceiver.
  2. Insert the SFP module into the SFP slot and firmly press it into place.

To remove the SFP module, follow these steps:

  1. Wear an ESD-preventive wrist or ankle strap to prevent ESD damage to the transceiver.
  2. Disconnect the network fiber-optic cable from the SFP module.
  3. Remove the protective dust plug from the SFP module.
  4. Pull the safety latch downwards to release the SFP module, and then pull it out from the slot.
  5. Plug a fiber-optic cable into the SFP module. Note that the SF works without any additional configuration.
  6. Reinstall the protective dust plug in the SFP module’s optical bores and place it on an antistatic mat or a static shielding bag.

Please note that you should not touch the output pins on the transceiver with your hand and always keep the protective dust plug on the SFP module’s optical bores until you are ready to make a connection. Also, do not point or stare directly into the beam or into the optical port of the transceiver when it is operating, as this can injure your eyesight.

To connect the SFP module, use only the TL-SM321A&TL-SM321B together, and TL- SM321A-2&TL-SM321B-2 together for fast and reliable connectivity between switches. For simplicity, we will take TL-SM321A&TL-SM321B as an example.

For any questions, technical support, or other information, please visit https://www.tp-link.com/support or email techwriter@tp- link.com.cn.
If you have any suggestions or needs on the product guides, welcome to email techwriter@tp-link.com.cn.

To ask questions, find answers, and communicate with TP-Link users or engineers, please visit https://community.tp-link.com to join TP-Link Community.
For technical support and other information, please visit https://www.tp- link.com/support, or simply scan the QR code.

If you have any suggestions or needs on the product guides, welcome to email techwriter@tp-link.com.cn.

Install the SFP

  1. Wear an ESD-preventive wrist or ankle strap to prevent ESD damage to the transceiver.

  2. Insert the SFP into the SFP slot and firmly press it into place.

  3. Remove the protective dust plug from the SFP.

  4. Plug a fiber-optic cable into the SFP. Note that the SFP works without any additional configuration.

Remove the SFP

  1. Wear an ESD-preventive wrist or ankle strap to prevent ESD damage to the transceiver.

  2. Disconnect the network fiber-optic cable from the SFP.

  3. Pull the safety latch downwards to release the SFP, and then pull it out from the slot.

  4. Reinstall the protective dust plug in the SFP’s optical bores and place it on antistatic mat or a static shielding bag.

Note:

  1. Do not touch the output pins on the transceiver with your hand.
  2. Always keep the protective dust plug on the SFP’s optical bores until you are ready to make a connection.

Caution:
DO NOT point or stare directly into the beam or into the optical port of the transceiver when it is operating, as this can injure your eyesight.

Connection

Use only the TL-SM321A&TL-SM321B together, and TL-SM321A-2&TL-SM321B-2 together for fast and reliable connectivity between switches. For simplicity, we will take TL-SM321A&TL-SM321B as an example.

tp-link-TL-SM321A-2-1000Base-BX-WDM-8

Product Specifications

General Specifications

Normal : TL-SM321A : TL-SM321B

  • Wave Length Tx: 1550 nm Tx: 1310 nm Rx: 1310 nm Rx: 1550 nm
  • Standards and Protocols EEE 802.3z, TCP/IP Cable Single-mode
  • Fiber Fiber Type 9/125 um Single-mode Max.
  • Cable Length 20 km
  • Data Rate 1.25 Gbps Port Type LC
  • Simplex Power Support 3.31
  • Safety & Emission FCC, CE DDM Yes
  • SFP-MSA Yes
  • Hot Swappable Yes

Normal : TL-SM321A-2

  • Wave Length Tx 1550 nm Rx: 1310 nm
  • Standards and Protocols IEEE 802.3z. TCP/P Cable
  • Fiber Type Max. Cable Length Data Rate
  • Port Type Power Support Safety & Emission DDM SFP-MSA
  • Hot Swappable Single-mode Fiber 9/125 um
  • Single-mode 2 km 1.25 Gbps LC
  • Simplex 3.3V FCC, CE Yes Yes Yes TL-SM321B-2 Tx 1310 nm Rx 1550 nm

Environmental and Physical Specifications

  • Product Operating Temperature 0˚C to 70˚C (32˚F to 158˚F)
  • Storage Temperature -40˚C to 85˚C (-40˚F to 185˚F)
  • Operating Humidity 10% to 90% RH, Non-condensing
  • Storage Humidity 5% to 90% RH, Non-condensing

TP-Link Compatible Products

  • TP-Link Switches with gigabit SFP Slots
  • MC220L

Note:
The SFP modules may be incompatible with other vendors’ devices. We recommend that you use only TP-Link SFP modules on your TP-Link devices.

FCC compliance information statement

Product Name: 1000Base-BX WDM Bi-Directional SFP Module
Model Number: TL-SM321A/TL-SM321B/TL-SM321A-2/TL-SM321B-2
Responsible party: TP-Link USA Corporation
Address: 10 Mauchly, Irvine, CA 92618
Website: https://www.tp-link.com/us/
Tel: +1 626 333 0234
Fax: +1 909 527 6804
E-mail: sales.usa@tp-link.com
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
We, TP-Link USA Corporation, has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.

EU Declaration of Conformity

TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp- link.com/en/ce

UK Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant
provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device.
  • Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning. Do not point or stare directly into the beam or into the optical port of the transceiver when it is operating, as this can injure your eyesight.

BSMI Notice
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)

CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Explanation of the symbols on the product label
Note: The product label can be found at the bottom of the product.
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer when he buys a new electrical or electronic equipment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals