antaira INJ-C201G-at-24 Series Industrial Gigabit PoE with Injector User Manual

June 13, 2024
antaira

antaira INJ-C201G-at-24 Series Industrial Gigabit PoE with Injector

antaira-INJ-C201G-at-24-Series-Industrial-Gigabit-PoE-with-Injector-
product

Product Information

Product Name: Antaira Technologies – Industrial Gigabit PoE+ Injector INJ-C201G-at-24 Series
Model: INJ-C201G-at-24
Version: 1.0
Description: The Antaira Technologies Industrial Gigabit PoE+ Injector is an industrial-grade device that provides Gigabit Ethernet connectivity and Power over Ethernet  (PoE) capabilities. It is designed to power and connect PoE-enabled devices such as IP cameras, wireless access points, and VoIP phones in industrial environments.

Key Features:

  • Embedded 110/100/1000Tx(PSE 30W) and 110/100/1000Tx copper port
  • Compliant IEEE802.3af/at PoE technologies
  • Support auto detection and classification for PoE application
  • Support short-circuit and current-overloading protection for PoE application
  • The total length from the device A through the Injector to the device B must not exceed 100 meters
  • Dual 12-55VDC redundant power inputs
  • 1*4-pin removal terminal block
  • Max. current 2.7A (Included PoE power budget)
  • Max. PoE output: 30W
  • IP30 protection
  • DIN-Rail and wall mount design

Product Usage Instructions

**Mounting Installation

DIN-Rail Mounting:**

  1. Choose a suitable location for mounting the injector on a DIN rail.
  2. Attach the DIN-Rail mounting brackets to the injector using the provided screws.
  3. Securely mount the injector onto the DIN rail.

Wall Mounting:

  1. Choose a suitable location for mounting the injector on a wall.
  2. Attach the wall mounting brackets to the injector using the provided screws.
  3. Securely mount the injector onto the wall.

Hardware Installation
Installation Steps:

  1. Ensure that the power source is disconnected before proceeding.
  2. Connect the Ethernet cable from the network device to the 1*10/100/1000Tx copper port of the injector.
  3. If required, connect a power source to the dual 12-55VDC redundant power inputs using the 1*4-pin removal terminal block.
  4. If using PoE, connect the PoE-enabled device to the PoE port of the injector using an Ethernet cable.
  5. Once all connections are made, apply power to the injector by connecting the power source.

Troubleshooting
If you encounter any issues with the Industrial Gigabit PoE+ Injector, refer to the troubleshooting section in the user manual (Page 12) for guidance on resolving common problems.

© Copyright 2023 Antaira Technologies, LLC.
All Rights Reserved
This document contains information, which is protected by copyright. Reproduction, adaptation or translation without prior permission is prohibited, except as allowed under the copyright laws.

Trademark Information
Antaira is a registered trademark of Antaira Technologies, LLC, Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp. NetWare is the registered trademark of Novell Inc. WMM and WPA are the registered trademarks of Wi-Fi Alliance. All other brand and product names are trademarks or registered trademarks of their respective owners.
Notice : Copyrights © 2023 by Antaira Technologies, LLC. All rights reserved. Reproduction, adaptation, or translation without prior permission of Antaira Technologies, LLC. is prohibited, except as allowed under the copyright laws.

Disclaimer
Antaira Technologies, LLC. provides this manual without warranty of any kind, expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. Antaira Technologies, LLC. may make improvements and/or changes to the product and/or specifications of the product described in this manual, without prior notice. Antaira Technologies, LLC. will not be liable for any technical inaccuracies or typographical errors found in this guide. Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual. The information contained is subject to change without prior notice.

FCC Notice

This equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution : Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.

CE Mark Warning
This is a Class-A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Industrial Gigabit PoE+ Injector

Industrial Grade Gigabit PoE+ Injector
User Manual
Version 1.0 (September 2023)
This manual supports the following models:

  • INJ-C201G-at-24
  • INJ-C201G-at-24-T

This document is the current official release manual. Please check our website (www.antaira.com) for any updated manual or contact us by e-mail (support@antaira.com).

Overview

  • PoE and Non-PoE are both highly utilized in industrial networking applications nowadays; however, it sometimes becomes an awkward situation the end device, e.g. remote camera, supports the PoE function but the Ethernet switch does not. Is there any other solution but replacing the switch with a PoE one?
  • INJ-C201G-at-24 Series solves the problem simply by deploying data and power from a non-PoE switch and power input to the PD device. PoE injector is a brilliant low-cost solution for the case that only one side of the device supports PoE  function. Therefore, the INJ-C201G-at-24 Series will be your best choice to deal with the lack of PoE function cases.
  • INJ-C201G-at-24 Series supports low voltage 24VDC model with power booster technology, ensuring full 30W PoE output, for better usage in the automation industry. INJ-C201G-at-24 Series with fanless design, besides extending surely apply to various industrial applications, INJ-C201G-at-24-T Series works perfectly in polarized temperatures from -40~75℃ and undoubtedly becomes your best option in the industrial market.

Key Features

  • System Interface/Performance
    • Embedded 110/100/1000Tx(PSE 30W) and 110/100/1000Tx copper port
    • Compliant IEEE802.3af/at PoE technologies
    • Support auto detection and classification for PoE application
    • Support short-circuit and current-overloading protection for PoE application
    • The total length from the device A through the Injector to the device B must not exceed 100 meters
  • Power Input
    • Dual 12-55VDC redundant power inputs
    • 1*4-pin removal terminal block
    • Max. current 2.7A (Included PoE power budget)
    • Max. PoE output: 30W
  • Operating Temperature
    • Standard operating temperature model: -10°C ~ 65°C
    • Extended operating temperature model (–T): -40°C ~ 75°C
  • Case/Installation
    • IP30 protection
    • DIN-Rail and wall mount design

Package Contents

  • 1 x Quick Installation Guide
  • 1 x INJ-C201G-at-24(-T)
  • 1 x Wall mounting brackets and screws
  • 1 x DC cable – 18 AWG & DC jack 5.5×2.1mm

Safety Precaution

Attention : If the DC voltage is supplied by an external circuit, please use a protection device on the power supply input. The industrial PoE injector’s hardware specs, ports, cabling information, and wiring installation will be described within this user manual.

Hardware Description

Physical Dimensions
Figure 2.1, below, shows the physical dimensions of Antaira Technologies’ INJ- C201G-at-24 series: Industrial Gigabit PoE+ Injectorantaira-INJ-C201G-at-24
-Series-Industrial-Gigabit-PoE-with-Injector-fig-1

Front Panel
On the front panel of the Power over Ethernet Injector is equipped with two RJ-45 ports and three LED indicators. See Figure 2.2.

antaira-INJ-C201G-at-24-Series-Industrial-Gigabit-PoE-with-Injector-
fig-2

Top View
Figure 2.3, below, shows the top panel of the INJ-C201G-at-24 series injector that is equipped with one 4-pin removal terminal block connector for dual 12-55VDC power inputs.antaira-INJ-C201G-at-24-Series-Industrial-Gigabit-PoE-
with-Injector-fig-3

LED Indicators
There are LED light indicators located on the front panel of the industrial PoE Injector that display the power status and PoE status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.4.

LED Color Description

PWR

|

Green

| On| Power input 1 or 2 is active
Off| Power input 1 and 2 is inactive

PoE

|

Green

|

On

| The port is supplying power to the powered- device

Off

| No powered-device attached or power supplying fails

Ethernet Ports
RJ-45 Ports
RJ-45 Ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for 10/100/1000Base-T or 1000Base-Tx devices connections. Auto MDI/MDIX means that the port can connect to another injector or workstation without changing the straight-through or crossover cabling. See the figures shown below for straight-through and crossover cabling schematics.

RJ-45 Pin Assignments (Table 2.5)

Pin Number Assignment
1 Rx+
2 Rx-
3 Tx+
6 Tx-

Note: The “+” and “-” signs represent the polarity of the wires that make up each wire pair.

The table below shows the 10BASE-T/100BASE-TX MDI port pinouts.

Pin MDI-X Signal Name MDI Signal Name
1 Receive Data plus (RD+) Transmit Data plus (TD+)
2 Receive Data minus (RD-) Transmit Data minus (TD-)
3 Transmit Data plus (TD+) Receive Data plus (RD+)
6 Transmit Data minus (TD-) Receive Data minus (RD-)

The following figures show the cabling schematics for straight-through and crossover cables.antaira-INJ-C201G-at-24-Series-Industrial-Gigabit-PoE-with-
Injector-fig-4

Cabling

  • Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 1000Base TX standard (e.g. Category 5, 5e, 6, or 6a). The cable between the equipment and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.

Note : Cable size should be between 18~20 AWG and the torque should be tightened to 5lbs.

Wiring the Power Inputs
Please follow the below steps to insert the power wire.

  1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)contacts on the terminal block connector as shown below in Figure 2.7.1
  2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in figure 2.7.2

Mounting Installation

DIN-Rail Mounting
The DIN-Rail is pre-installed on the industrial PoE injector from the factory. If the DIN-Rail is not on the industrial PoE injector, please refer to Figure 3.1 to learn how to install the DIN-Rail on the injector.

Figure 3.1.1
The Rear Side of the Injector and DIN-Rail Bracket

Follow the steps below to learn how to hang the industrial PoE injector.

  1.  Use the screws to install the DIN-Rail bracket on the rear side of the injector.
  2. To remove the DIN-Rail bracket, do the opposite from step 1.
  3. After the DIN-Rail bracket is installed on the rear side of the injector, insert the top of the DIN-Rail onto the track as shown below in Figure 3.1.2
  4. Lightly pull down the bracket onto the rail as shown below in Figure 3.1.3
  5. Check if the bracket is mounted tightly on the rail.
  6. To remove the device from the rail, do the opposite of the above steps.antaira-INJ-C201G-at-24-Series-Industrial-Gigabit-PoE-with-Injector-fig-8

Wall Mounting
Follow the steps below to mount the device using the wall mounting bracket as shown below in Figure 3.2.

  1. Remove the DIN-Rail bracket from the device by loosening the screws.
  2. Place the wall mounting brackets on the top and bottom of the device.
  3. Use the screws to screw the wall mounting bracket on the device.
  4. Use the hook holes at the corners of the wall mounting bracket to hang the device on the wall.
  5. To remove the wall mount bracket, do the opposite from the steps above.

antaira-INJ-C201G-at-24-Series-Industrial-Gigabit-PoE-with-Injector-
fig-9

Hardware Installation

Installation Steps
This section will explain how to install Antaira’s INJ-C201G-at-24 series:

Caution : This device is intended for use indoors and at altitudes up to 2000 meters.
Caution : The device is intended to be installed in an industrial control enclosure and panel.

Installation Steps

  1. Unpack the industrial PoE injector from the original packing box.

  2. Check if the DIN-Rail bracket is screwed on the industrial PoE injector.

    • If the DIN-Rail is not screwed on the industrial PoE injector, please refer to the DIN-Rail Mounting section for DIN-Rail installation.
    • If you want to wall mount the industrial PoE injector, please refer to the Wall Mounting section for wall mounting installation.
  3. To hang the industrial PoE injector on a DIN-Rail or wall, please refer to the Mounting Installation section.

  4. Power on the industrial PoE injector and then the power LED light will turn on.

    • If you need help on how to wire power, please refer to the Wiring the Power Inputs section.
    • Please refer to the LED Indicators section for LED light indication.
  5. Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection.

  6. Insert one side of the RJ-45 cable into the injector’s Ethernet port and on the other side into the networking device’s Ethernet port, e.g. switch PC or server. The Ethernet port’s (RJ-45) LED on the industrial PoE injector will turn on when the cable is connected to the networking device.
    Please refer to the LED Indicators section for LED light indication.

  7. When all connections are set and the LED lights all show normal, the installation is complete.

Maintenance and Service

  • If the device requires servicing of any kind, the user is required to disconnect and remove it from its mounting. The initial installation should be done in a way that makes this as convenient as possible.
  • Voltage/Power lines should be properly insulated as well as other cables. Be careful when handling them so as to not trip over.
  • Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces of the device. This may not only harm the internal layout but might cause harm to the user as well.
  • Do not under any circumstance open the device for any reason. Please contact your dealer for any repair needed or follow the instructions within the manual.
  • Clean the device with dry soft cloth.

Trouble Shooting

  • Always verify the right power cord or adapter is being used. Never use a power supply or adapter with a non-compliant DC output voltage or it will burn the equipment.
  • Select the proper UTP or STP cable in order to construct the network. Use an unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: Also, be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
  • Diagnosing LED Indicators: To assist in identifying problems, the device can be easily monitored with the LED indicators which help to identify if any problems exist.
    • Please refer to the LED Indicators section for LED light indication.
  • If the power indicator LED does not turn on when the power cord is plugged in, the user may have a problem with the power cord. Check for loose power connections, power losses or surges at the power outlet.
    • Please contact Antaira for technical support services, if the problem still cannot be resolved.
  • If the industrial PoE injector LED indicators are normal and the connected cables are correct but the packets still cannot transmit, please check the system’s Ethernet devices’ configuration or status.

Antaira Customer Service and Support (Antaira US Headquarter) + 844-268-2472 (Antaira Europe Office) + 48-22-862-88-81 (Antaira Asia Office) + 886-2-2218-9733 Please report any problems to Antaira:
www.antaira.com / support@antaira.com www.antaira.eu / info@antaira.eu
www.antaira.com.tw / info@antaira.com.tw
Any changes to this material will be announced on the Antaira website.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

antaira User Manuals