intertek LYT1-L Heated Throw Blanket Electric Blanket User Manual

June 17, 2024
Intertek

LYT1-L Heated Throw Blanket Electric Blanket

“`html

Specifications

  • Product Name: Heated Throw

  • Brands: LanYu, CHENLANYU, Homemate, JKMAX,
    Yokimisu, CAROMIO, Codi, DEGREES OF COMFORT, H | HYDE LANE, COZYTY,
    LIFEHUG, TRUSTWARMTH, and more

  • Description Models: LYT1-L, LYT1-F,
    HMHB-5060a, HMHB-5060b, HMHB-5060c, HMHB-5060p, YHB-R60,
    YCDMEB5060

  • Ratings: 120Vac, 60Hz, 105W; 120Vac, 60Hz,
    100W

Product Description

The Heated Throw is designed for household and indoor use only.
It includes an in-line-cord temperature controller and a power
supply cord terminating with a 2-wire polarized plug. The available
models include LYT1-L, LYT1-F, HMHB-5060a, HMHB-5060b, HMHB-5060c,
HMHB-5060p, YHB-R60, and YCDMEB5060.

Product Usage Instructions

1. Safety Precautions

Before using the Heated Throw, read all instructions and safety
information provided in the manual.

2. Unpacking and Setup

Remove the Heated Throw from its packaging. Ensure the power
cord is not damaged and plug it into a suitable electrical
outlet.

3. Temperature Control

Use the in-line-cord temperature controller to adjust the heat
settings according to your preference. Always monitor the
temperature to avoid overheating.

4. Care and Maintenance

When not in use, unplug the Heated Throw. Follow the cleaning
instructions provided in the manual to keep the product in good
condition.

5. Storage

Store the Heated Throw in a cool, dry place when not in use.
Avoid folding the product excessively to prevent damage to the
heating elements.

FAQ

Q: Can I wash the Heated Throw in a washing machine?

A: No, it is not recommended to wash the Heated Throw in a
washing machine. Refer to the cleaning instructions for proper
maintenance.

Q: What should I do if the Heated Throw stops working?

A: Check the power supply and ensure the connections are secure.
If the issue persists, contact customer support for assistance.

“`

Listing Constructional Data Report (CDR)

1.0 Reference and Address Report Number 230522230GZU-001

Original Issued: 7-Jul-2023

Revised: 15-Sep-2023

Standard(s)

Electrically Heated Bedding [UL 964:2011 Ed.12+R:05Jun2015] Electrically Heated Bedding Appliances for Household Use [CSA C22.2#101:2017 Ed.3]

Applicant
Address
Country Contact Phone
FAX Email

Bluetex Health technology Co.,Ltd
No. 88, South of Qisheng Road, PaojiangYuecheng District, Shaoxing City Zhejiang Province 312000 China Haigen Zhang 15157577622 NA [email protected]

Manufacturer Bluetex Health technology Co.,Ltd

Address
Country Contact Phone
FAX Email

No. 88, South of Qisheng Road, PaojiangYuecheng District, Shaoxing City Zhejiang Province 312000 China
Haigen Zhang
15157577622
NA
[email protected]

draft report

Page 1 of 40

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 2 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

2.0 Product Description

Product Brand name

Heated Throw
LanYu, CHENLANYU, Homemate, JKMAX, Yokimisu, CAROMIO, Codi, DEGREES OF COMFORT, H | HYDE LANE, COZYTY, LIFEHUG, TRUSTWARMTH, CHENLANYU, Gasky, Entil, JETERY, MaxKare, MARNUR, Curecure, Maxkahome, OHSEE, AOSEE, Z3GOGO, QCUQ, Bedsure, Guohaoi, ydw, dowin, Homemate, JKMAX, blunique, CHRUN, BENFOX, JOCULAR, Gostery, MAXEVE, Cuouou, RESTCAT, CHICTEX, OUROSE, OKCHILD, TECKELE, Yokimisu, ESTINGO, CHIOKY, FOCO, STARBEDIA, YANYEA, Longering, Klaggie.

Description Models

The product covered by this report is Heated Throw, for household and indoor use only, provided with a in-line-cord temperature controller, which equipped with power supply cord terminating with a 2-wire polarized plug.
LYT1-L, LYT1-F, HMHB-5060a, HMHB-5060b, HMHB-5060c, HMHB-5060p, YHB-R60, YCDMEB5060.

Model Similarity Refer to Illustration 8 in section 7.

Ratings

120Vac, 60Hz, 105W. 120Vac, 60Hz, 100W.

Other Ratings NA

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product Photographs
Photo 1 – External view for model LYT1-L

Page 3 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023
1a

draft report

Photo 2 – External view for model LYT1-F
1b

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product Photographs
Photo 3 – Internal View

Page 4 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

2

draft report

Photo 4 – View of Temperature Controller

3

4

5d 5c

5b

5a

5

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product Photographs
Photo 5 – View of Temperature Controller

Page 5 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

Photo 6 – View of Temperature Controller
ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs

Page 6 of 40

Photo 7 – View of PCB of Temperature Controller

5e

5f

5g

5h

5i

5j 5m

Issued: 7-Jul-2023 Revised: 15-Sep-2023

5k

5l

5n

5o

draft report

Photo 8 – View of Connector
6

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product Photographs
Photo 9 – View of Connector

Page 7 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

Photo 10 – View of Connector
6b 6a 6c 6d

6e 6f 6g
ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product Photographs
Photo 11 – View of Inner Fabric

Page 8 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023
9

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs

Page 9 of 40

Photo 12 – View Temperature Controller type LY01A series

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs

Page 10 of 40

Photo 13 – View Temperature Controller type LY01A series

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product Photographs
Photo 14 – External view of model YHB-R60

Page 11 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs

Page 12 of 40

Photo 15 – View of Temperature Controller type LY13A

Issued: 7-Jul-2023 Revised: 15-Sep-2023

5

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

4.0 Critical Components Item no.1 Name

Manufacturer/ trademark2

Photo #

1 1a Outer Fabric

Bluetex Health technology Co., Ltd.

2 1b Outer Fabric

Bluetex Health technology Co., Ltd.

1

1c

Outer Fabric (not shown)

Bluetex Health technology Co., Ltd.

draft report

Page 13 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

Type / model2 Nap cloth
Flannel PV Fabric

Technical data and securement means

Mark(s) of conformity
3

The material is 100% polyester

with a weight of 170 g/m² (±10%),

180g/m² (±10%), 190 g/m² (±

10%), 210 g/m² (±10%) or 230

g/m² (±10%). The material creates the top and

NR

bottom layer of the throw

construction and are hemmed and

sewn. Refer to Illustration 5 for

details.

The material is 100% polyester

with a weight of 190 g/m² (±10%),

210 g/m² (±10%), 230 g/m² (±

10%), 220 g/m² (±10%) or 170

g/m² (±10%). The material creates the top and

NR

bottom layer of the throw

construction and are hemmed and

sewn. Refer to Illustration 5 for

details.

The material is 100% polyester

with a weight of 260 g/m² (±10%).

The material creates the top and

bottom layer of the throw

NR

construction and are hemmed and

sewn. Refer to Illustration 5a for

details.

The material is 100% polyester

with a weight of 260 g/m² (±10%).

The material creates the top and

bottom layer of the throw

NR

construction and are hemmed and

sewn. Refer to Illustration 5 for

details.

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 14 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

Photo #

4.0 Critical Components Item no.1 Name

Manufacturer/ trademark2

Type / model2

Technical data and securement means

Mark(s) of conformity
3

3 2 Heater Wire

TOTOKU ELECTRIC CO LTD

10932

4 3 Interconnect Cord Various

4

4

Power Supply Cord Set

4, 15

5

Temperature Controller

Various
Bluetex Health technology Co., Ltd. Bluetex Health technology Co., Ltd. Bluetex Health technology Co., Ltd.

SPT-2 SPT-2 SPT-2 LY-T-01
LY01A series
LY13A

4 5a Enclosure

CHI MEI CORPORATION

PA-765A(+)

Rated 150V, 105°C, 7 /m, VW-1, 15m in length, thermoplastic insulated heater/sensor wires. Refer to Illustration 5, 6 for details.

cURus

Rated 150V, 105°C, 5.6 /m for first resistance wire and 5/m for second resistance wire, VW-1, thermoplastic insulated heater/sensor wires. Refer to Illustration 5a, 6a for details. Rated 18AWG x 3C, 300V, VW-1, 105°C. Molded with a strain relief Rated 20AWG x 3C, 300V, VW-1, 105°C. Molded with a strain relief Rated 18AWG x 2C, rated 300 V, VW-1, 105 °C. Provided with a

cURus
cULus cETLus cULus cETLus cULus cETLus

Rated 120V, 60Hz, 105W. Consists of item 5a thru 5o.

See 5.0 See 5.0

Rated 120V, 60Hz, 105W. Consists of item 5a thru 5o.

NR

ABS material. Rated V-0, HWI=3, HAI=0, CTI=1, 80°C. Measured 2.0mm thick minimum. Upper and lower parts provided, secured together by screws.

cURus

draft report

4 5b Switch Button 4 5c LED Cover 4 5d Cord Bushing

CHI MEI CORPORATION

PA-765A(+)

FORMOSA PLASTICS CORP

FM090

POLYONE CORP 6602(f1)

ABS material. Rated V-1, 80°C. Measured 1.5mm thick minimum.
POM material. Rated HB, 90ºC, Min. 1.5mm thick. PVC material. Rated V-0, HWI-2, HAI=0, CTI=0, 105°C. Measured 1.5mm thick minimum.

cURus cURus cURus

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 15 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

Photo #

4.0 Critical Components Item no.1 Name
7 5e Current Fuse 7 5f Varistor 7 5g X2 Capacitor 7 5h Resistor
7 5i Thermal link 7 5j Capacitor 7 5k Resistor 7 5l Resistor 7 5m Triac 7 5n IC

7 5o PCB

8

6

Connector Assembly

10

6a

Male Connector Securement

10

6b

Male Throw Connector

10 6c Connector PCB

10

6d

Male Connector Terminals

draft report

Manufacturer/ trademark2
Various Various Various
Various

Type / model2
Various 7D241K 7D391K
Various

Various
XIAMEN SET ELECTRONICS CO LTD Various
Various

Various
H1 Various Various

Various

Various

Various

BT136

Cmsemicon

CMS89F113

Various

Various

Bluetex Health technology Co., Ltd.

LY-01

Various

Various

TEIJIN CHEMICALS PLASTIC COMPOUNDS SHANGHAI LTD

LN-2520(##)

Various

Various

Various

Various

Technical data and securement means
F1. Rated 3.15A, 250VAC VR1. Rated 150VAC, 240VDC. VR1. Rated 250VAC, 390VDC. (CX1). Rated 275VAC 0.1uF, T100 (R12, R16). Oxide film resistor. Rated 2K ohm, 1W.

Mark(s) of conformity
3
cURus cURus cURus
cURus
NR

Rated 2A 250VAC, Tf=102°C.

cURus

(C1). Rated 400V, 1uF. (R3). Oxide film resistor. Rated 100 ohm, 1W. (R6). Metal oxide film resistor. Rated 0.33 ohm, 1W. (T1). Each rated 600V, 4A, Tj=125 °C. (U1). 16 pin. Software Checksum: AB91. Rated V-0, 130 °C, met UL796. Measured 1.6 ± 0.1mm thick minimum. Secured to Enclosure by screws. Rated 120V, 60Hz, 1.5A. Consisted following items 6a thru 6g: Secured by stitching through the top and bottom layer, and through the reinforcement patch. Buttonhole is sewn through the reinforcement patch and material. Stitching also runs through all layers for approx. one inch along the top of the “T” shaped connector. The reinforcement patch consists of one layer of 100% non-woven polyester material.

NR NR NR NR NR UR See 5.0
NR

PC material, rated V-0, HWI=3, HAI=0, CTI=2, 125°C. Measured 1.5mm thick minimum.

cURus

Rated V-0, 130°C, secured within

connector enclosure with integral

UR

tabs.

3 provided. Tinned copper, shaped as shown.

NR

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 16 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

Photo #

4.0 Critical Components Item no.1 Name

Manufacturer/ trademark2

Type / model2

10

6e

Female Cover

Connector

POLYONE

CORP

6602(f1)

TEIJIN

10

6f

Female Connector Enclosure

CHEMICALS PLASTIC COMPOUNDS

LN-2520(##)

SHANGHAI LTD

10

6g

Female Connector Terminals

Various

Various

Technical data and securement means

Mark(s) of conformity
3

PVC material. Rated V-0, HWI=2, HAI=0, 105°C. PVC tube added for additional strain relief.

cURus

PC material, rated V-0, HWI=3, HAI=0, CTI=2, 125°C. Measured 1.5mm thick minimum.

cURus

3 provided. Clear plated brass.

NR

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 17 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

Photo #

4.0 Critical Components Item no.1 Name

Manufacturer/ trademark2

Type / model2

Technical data and securement means

Mark(s) of conformity
3

Rating/Washing/

1

7

Warning Label on Blanket (not

Various

shown)

Various

100% polyester, 100 g/m2. Permanent ink printing directly on the label by silk screening, and all NR the four edges were secured by stitching.

Label on

1

8

Temperature Controller (not

shown)

Various

Various

Rated 80°C and suitable for ABS

material. Molding, stamping, silk-

UR

screen are all acceptable.

11 9 Inner Fabric

Bluetex Health technology Co., Ltd.

Non-woven

For Model LYT1-F, HMHB-5060b,

HMHB-5060c, HMHB-5060p. The material is 100% polyester with a

NR

weight of 40 g/m² (±10%).

NOTES:

  1. Not all item numbers are indicated (called out) in the photos, as their location is obvious.

  2. “Various” means any type, from any manufacturer that complies with the “Technical data and securement means” and meets the “Mark(s) of conformity” can be used.

  3. Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. “NR” – indicates Unlisted and only visual examination is necessary. “See 5.0″ indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
5.0 Critical Unlisted CEC Components

Page 18 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

SUBASSEMBLY Photo # Item no. Name

Manufacturer/Trademark Type / model

4, 15

5

Temperature Controller

Bluetex Health technology Co., Ltd.

LY-T-01

Electrical Rating:

Rated 120V, 60Hz, 105W

Insulation class NA

Component Standard used:

UL 60730-1:2016 Ed.5 & UL 60730-2-9:2017 Ed.4 CSA E60730-1:2015, Ed.5 & CSA E60730-2-9:2015 Ed.3

COMPONENTS LIST (refer to illustration 3 and 4 for assembly drawing)

Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no.

4

5a

4

5b

4

5c

4

5d

7

5e

7

5f

7

5g

7

5h

7

5i

7

5j

7

5k

7

5l

7

5m

7

5n

7

5o

VERIFICATION PROCESS Frequency: Annual
Test Name Verify Construction

Test Site: CEC

Number of samples to test: 1

Test Parameters

Per the component descriptions noted above

SUBASSEMBLY

Photo # Item no. Name

Manufacturer/Trademark Type / model

8

6

Connector Assembly

Bluetex Health technology Co., Ltd.

LY-01

Electrical Rating:

120V, 60Hz, 1.5A

Insulation class NA

Component Standard used:

UL 1977:2016 Ed.3+R:17Nov2020 CSA C22.2#182.3:2016 Ed.2+U1

COMPONENTS LIST (refer to illustration 7 for assembly drawing)

Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no.

10

6a

10

6b

10

6c

10

6d

10

6e

10

6f

10

6g

draft report

VERIFICATION PROCESS Frequency: Annual
Test Name Verify Construction

Test Site: CEC

Number of samples to test: 1

Test Parameters

Per the component descriptions noted above

SUBASSEMBLY Photo # Item no. Name

Manufacturer/Trademark Type / model

4, 15

5

Temperature Controller

Bluetex Health technology Co., Ltd.

LY01A series

Electrical Rating:

Rated 120V, 60Hz, 105W

Insulation class NA

Component Standard used:

UL 60730-1:2016 Ed.5 & UL 60730-2-9:2017 Ed.4 CSA E60730-1:2015, Ed.5 & CSA E60730-2-9:2015 Ed.3

COMPONENTS LIST (refer to illustration 3 and 4a for assembly drawing)

Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no.

4

5a

4

5b

4

5c

4

5d

7

5e

7

5f

7

5g

7

5h

7

5i

7

5j

7

5k

7

5l

7

5m

7

5n

7

5o

VERIFICATION PROCESS Frequency: Annual
Test Name Verify Construction

Test Site: CEC

Number of samples to test: 1

Test Parameters

Per the component descriptions noted above

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 19 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

6.0 Critical Features Recognized Component – A component part, which has been previously evaluated by an accredited certification

body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability.
Listed Component – A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings.
Unlisted Component – A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition.
Critical Features/Components – An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product’s conformance to applicable requirements of the product standard.
Construction Details – For specific construction details, reference should be made to the photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply.
1. Spacing – In primary circuits Min. 1.6 mm are maintained through air and over surfaces of insulating material between current-carrying parts of opposite polarity and between bare live part and other non-current-carrying conductive parts. Min. 3.2 mm between bare live parts and an electrically conductive enclosure.
2. Mechanical Assembly – Components such as switches, fuseholders, connectors, wiring terminals and display lamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or other mounting format that prevents turning of the component.
3. Corrosion Protection – All ferrous metal parts are protected against corrosion by painting, plating or the equivalent.
4. Accessibility of Live Parts – All uninsulated live parts in primary circuitry are housed within a metal enclosure constructed with no openings other than those specifically described in Sections 4 and 5.
5. Polarized Connection – This product is provided with a polarized power supply connection. All single pole switches and fuses are connected only to the ungrounded supply circuit conductor.
6. Internal Wiring – Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating in soldered connections are made mechanically secure prior to soldering. Recognized Component separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is protected against abrasion or damage by plastic bushings or grommets.
7. Schematics – Refer to Illustration 3 for schematics requiring verification during Field Representative Inspection Audits.

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 20 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

6.0 Critical Features 8. Markings – The product is marked on a labeling system as described in item no.7 and 8 of section 4.0 or by
molding, or by silk-screen as follows: – applicant’s name or brand name – model number – electrical ratings (volts, input current & frequency) – date of manufacturing

9. Cautionary Markings – Refer to Illustration 1 for layouts.
10. Installation, Operating and Safety Instructions – Instructions for installation and use of this product are provided by the manufacturer as required by the standard. – For the separate hard card, material, instruction sheet or instruction booklet that is packed with the bedding, IMPORTANT ­ INSTRUCTIONS ­ DO NOT DESTROY, or the equivalent, in letters not less than 3/8 inch (9.5 mm) high. – The letter of contents was: for upper case letter, 3.2 mm high min., for lower case letter, 1.6 mm high min. – Refer to Illustration 2, 2a, 2b for details. – The instruction manual should be packed with the bedding.

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
7.0 Illustrations Illustration 1 – Cautionary Marking

Page 21 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

Notes: 1) For upper case letters 3.2 mm high min., for lower case letters 1.6 mm high min.
ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 2 – Instruction Manual

Page 22 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 2a – Instruction Manual

Page 23 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 2b – Instruction Manual

Page 24 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 3 – Circuit Diagram

Page 25 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 4 – PCB layout

Page 26 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
7.0 Illustrations

Page 27 of 40

Illustration 4a – PCB layout of Temperature Controller type LY01A series

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 28 of 40

7.0 Illustrations

Illustration 5 – Wiring diagram for heating wire

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
7.0 Illustrations

Page 29 of 40

Illustration 5a – Wiring diagram for heating wire of model YHB-R60

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 6 – Drawing of heater wire

Page 30 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 6a – Drawing of heater wire

Page 31 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 7 – Drawing of Connector

Page 32 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0 Illustrations
Illustration 8 – Model Similarity

Page 33 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

Model

Rated Power

Controller type

Controller quatity

Heater Size (inch) wire
length

LYT1-L LYT1-F

LY-T-01

HMHB5060a

HMHB5060b
105W LY01A
HMHB5060c

1

50”*60” 15 m

HMHB5060p

YCDMEB5060

LY13A

YHB-R60 100W LY01A-A

1

Ø60

21M

draft report

Heater wire resistance
R: 7.0 /m S: 7.0 /m
R: 5.6 /m S: 5.0 /m

Outer Fabric
Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%).
Flannel 190 g/m² (± 10%).
Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%) Flannel 190 g/m² (± 10%) or 210 g/m² (±
10%) Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%).
Flannel 190 g/m² (± 10%) or 230 g/m² (±
10%)
Nap cloth 180 g/m² (±10%)
PV Fabric 260 g/m² (±10%)
Flannel 190 g/m² (± 10%)
Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%).
Flannel 190 g/m² (± 10%) or 220 g/m² (±
10%)
Same as HMHB5060a, HMHB5060b, HMHB5060c, HMHB5060p, YHB-R60
Flannel 260 g/m² (± 10%)

Note: 1. Controller type LY01A-A and LY01A are similar, except model signation. 2. Controller type LY13A and LY01A are similar, except model signation and appearance.

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 34 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

8.0 Test Summary

Evaluation Period 22-May-2023 ~ 7-Jul-2023

Project No. 230522230GZU

Sample Rec. Date 22-May-2023

Condition Prototype

Sample

ID.

S230522230001~003

Test Location Test Procedure

Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Address: Room101/301/401/102/202/302/402/502/602/702/802, No. 7-2, Caipin Road, Huangpu District, Guangzhou, Guangdong, China
Testing Lab

Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.

Due to the previous testing performed under Intertek Report 190410076GZU-001, only the following testing was performed:

UL 964:2011

CSA

UL 746C:2018

Test Description

Ed.12+R:05Jun20 C22.2#101:2017 Ed.7 +

15

Ed.3

R:01Sep2021

Clause

Clause

Clause

Control Impact and Calibration

17

Resistance to Impact Test

56

8.1 Signatures

A representative sample of the product covered by this report has been evaluated and found to comply with the

applicable requirements of the standards indicated in Section 1.0.

Completed by:

Ming Yuan

Reviewed by:

Oliver Guo

Title:

Engineer

Title:

Senior Project Engineer

Signature:

Signature on file

Signature:

Signature on file

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 35 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

9.0 Correlation Page For Multiple Listings The following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.

BASIC LISTEE Bluetex Health technology Co.,Ltd

Address

No. 88, South of Qisheng Road, PaojiangYuecheng District, Shaoxing City Zhejiang Province 312000

Country Product

China Heated Throw

MULTIPLE LISTEE 1 Address Country
Brand Name

None

ASSOCIATED MANUFACTURER
Address Country

MULTIPLE LISTEE 1 MODELS

BASIC LISTEE MODELS

draft report

MULTIPLE LISTEE 2 Address Country
Brand Name

None

ASSOCIATED MANUFACTURER
Address Country

MULTIPLE LISTEE 2 MODELS

BASIC LISTEE MODELS

MULTIPLE LISTEE 3 Address Country
Brand Name

None

ASSOCIATED MANUFACTURER
Address Country

MULTIPLE LISTEE 3 MODELS

BASIC LISTEE MODELS

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 36 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

10.0 General Information The Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials.

COMPONENTS Components used shall be those itemized in this Intertek report covering the product, including any amendments

LISTING MARK The ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek.

The mark must include the following four items:

  1. applicable country identifiers “US” and/or “C” or “US”, “C” and “EU” 2) the word “Listed” or “Classified” or “Recognized Component” (whichever is appropriate) 3) a control number issued by Intertek 4) a product descriptor that identifies the standards used for certification. Example:

For US standards, the words, “Conforms to” shall appear with the standard number along with the word, ” Standard” or “Std.” Example: “Conforms to ANSI/UL Std. XX.”

For Canadian standards, the words “Certified to CAN/CSA Standard CXX No. XX.” shall be used, or abbreviated, “Cert. to CAN/CSA Std. CXX No. XX.”

Can be used together when both standards are used.

If all standards on the ATM have the same standard title, the shared title or its abbreviation may be used in place of the examples above. Example: “Medical Electrical Equipment” or “MEE”; “Information Technology Equipment” or “ITE”; “Audio/Video Information And Communication Technology Equipment” or “A/V ICTE”.

Note: A facsimile must be submitted to Intertek, Attn: Follow-up Services for approval prior to use. The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory assessment in your facility.

draft report

MANUFACTURING AND PRODUCTION TESTS Manufacturing and Production Tests shall be performed as required in this Report.
FOLLOW-UP SERVICE Periodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following:
1. Conformance of the manufactured product to the descriptions in this Report. 2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement. 3. Manufacturing changes. 4. Performance of specified Manufacturing and Production Tests.
In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the Applicant shall take one or more of the following actions:
1. Correct the non-conformance. 2. Remove the ETL Mark from non-conforming product. 3. Contact the issuing product safety evaluation center for instructions.

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 37 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

10.1 Evaluation of Unlisted Components Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated.

The Applicant will be notified, in writing, via the applicable contact methods, as defined in Section 1.0, when these components must be selected and sent to Component Evaluation Center (CEC) for reevaluation.

Due to particular testing requirements, some components may be requested to be shipped to specific labs. Thus, specific shipment destination(s) for each sample will be provided in the written notification.

Managing CEC Location: Intertek Testing Services Shenzhen Limited Guangzhou Branch ETL Component Evaluation Center Room 101/301/401/102/202/302/402/502/602/702/802, No. 7-2, Caipin Road, Huangpu Guangzhou, Guangdong, China Attn: Ms. Joey Kuang Sample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial component shipment.

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 38 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

11.0 Manufacturing and Production Tests The manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:

Required Tests
– Dielectric Voltage Withstand Test – Polarization Continuity Check Test

draft report

11.1 Dielectric Voltage Withstand Test Method One hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test. The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all switches, contractors, relays, etc., should be closed so that all primary circuits are energized by the test potential. If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made.
The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required.
Test Equipment The test equipment is to have the following features and characteristics: a) A means of indicating the test voltage that is being applied to the appliance under test. This may be accomplished by sensing the voltage at the test leads or by an equivalent means.
b) An output voltage that: 1) Has a sinusoidal waveform; 2) Has a frequency that is within the range of 40 ­ 70 Hz; and 3) Has a peak value of the waveform that is not to be less than 1.3 and not more than 1.5 times the rootmean-square value.
c) A means of effectively indicating unacceptable performance. The indication is to be: 1) Auditory if it can be readily heard above the background noise level; 2) Visual if it commands the attention of the operator; or 3) A device that automatically rejects an unacceptable product. If the indication of unacceptable performance is auditory or visual, the indication is to remain active and conspicuous until the test equipment is reset manually.
d) When the test equipment is adjusted to produce the test voltage and a resistance of 120,000 ohms is connected across the output, the test equipment is to indicate an unacceptable performance within 0.5 second. A resistance of more than 120,000 ohms may be used to produce an indication of unacceptable performance, if the manufacturer elects to use a tester having higher sensitivity.
Exception: The sensitivity of the test equipment may be reduced, a lower value of resistance may be used, when testing an appliance intended to be permanently wired.

Products Requiring Dielectric Voltage Withstand Test: Product All products covered by this Report.

Test Voltage 1240 V or 1480 V

Test Time 60 s 1 s

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 39 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

11.2 Polarization Continuity Check Test Method Each appliance shall be examined or tested for electrical continuity between the ungrounded circuit supply conductor of the attachment plug (narrower blade of the 2-wire plug), and the line switch and the control unit (if provided).
Test Equipment Any indicating device, such as an ohmmeter, a battery and buzzer combination, or the like, may be used to determine continuity.
Products Requiring Polarization Continuity Check Test: Product All products covered by this Report.

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd

Page 40 of 40

Issued: 7-Jul-2023 Revised: 15-Sep-2023

12.0 Revision Summary

The following changes are in compliance with the declaration of Section 8.1:

Date/

Project Handler/

Proj # Site ID Reviewer

Section Item Description of Change

15-Sep-2023 Seraph Wei

2.0

Added new brand names FOCO, STARBEDIA, YANYEA, Longering and Klaggie.

230913188GZU Oliver Guo

draft report

ED 16.3.15 (1-Jul-2022) Mandatory

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Intertek User Manuals

Related Manuals