intertek LYT1-L Heated Throw Blanket Electric Blanket User Manual
- June 17, 2024
- Intertek
Table of Contents
- LYT1-L Heated Throw Blanket Electric Blanket
- Specifications
- Product Description
- Product Usage Instructions
- 1. Safety Precautions
- 2. Unpacking and Setup
- 3. Temperature Control
- 4. Care and Maintenance
- 5. Storage
- Q: Can I wash the Heated Throw in a washing machine?
- Q: What should I do if the Heated Throw stops working?
LYT1-L Heated Throw Blanket Electric Blanket
“`html
Specifications
-
Product Name: Heated Throw
-
Brands: LanYu, CHENLANYU, Homemate, JKMAX,
Yokimisu, CAROMIO, Codi, DEGREES OF COMFORT, H | HYDE LANE, COZYTY,
LIFEHUG, TRUSTWARMTH, and more -
Description Models: LYT1-L, LYT1-F,
HMHB-5060a, HMHB-5060b, HMHB-5060c, HMHB-5060p, YHB-R60,
YCDMEB5060 -
Ratings: 120Vac, 60Hz, 105W; 120Vac, 60Hz,
100W
Product Description
The Heated Throw is designed for household and indoor use only.
It includes an in-line-cord temperature controller and a power
supply cord terminating with a 2-wire polarized plug. The available
models include LYT1-L, LYT1-F, HMHB-5060a, HMHB-5060b, HMHB-5060c,
HMHB-5060p, YHB-R60, and YCDMEB5060.
Product Usage Instructions
1. Safety Precautions
Before using the Heated Throw, read all instructions and safety
information provided in the manual.
2. Unpacking and Setup
Remove the Heated Throw from its packaging. Ensure the power
cord is not damaged and plug it into a suitable electrical
outlet.
3. Temperature Control
Use the in-line-cord temperature controller to adjust the heat
settings according to your preference. Always monitor the
temperature to avoid overheating.
4. Care and Maintenance
When not in use, unplug the Heated Throw. Follow the cleaning
instructions provided in the manual to keep the product in good
condition.
5. Storage
Store the Heated Throw in a cool, dry place when not in use.
Avoid folding the product excessively to prevent damage to the
heating elements.
FAQ
Q: Can I wash the Heated Throw in a washing machine?
A: No, it is not recommended to wash the Heated Throw in a
washing machine. Refer to the cleaning instructions for proper
maintenance.
Q: What should I do if the Heated Throw stops working?
A: Check the power supply and ensure the connections are secure.
If the issue persists, contact customer support for assistance.
“`
Listing Constructional Data Report (CDR)
1.0 Reference and Address Report Number 230522230GZU-001
Original Issued: 7-Jul-2023
Revised: 15-Sep-2023
Standard(s)
Electrically Heated Bedding [UL 964:2011 Ed.12+R:05Jun2015] Electrically Heated Bedding Appliances for Household Use [CSA C22.2#101:2017 Ed.3]
Applicant
Address
Country Contact Phone
FAX Email
Bluetex Health technology Co.,Ltd
No. 88, South of Qisheng Road, PaojiangYuecheng District, Shaoxing City
Zhejiang Province 312000 China Haigen Zhang 15157577622 NA lyht05@cnlyht.com
Manufacturer Bluetex Health technology Co.,Ltd
Address
Country Contact Phone
FAX Email
No. 88, South of Qisheng Road, PaojiangYuecheng District, Shaoxing City
Zhejiang Province 312000 China
Haigen Zhang
15157577622
NA
lyht05@cnlyht.com
draft report
Page 1 of 40
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 2 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
2.0 Product Description
Product Brand name
Heated Throw
LanYu, CHENLANYU, Homemate, JKMAX, Yokimisu, CAROMIO, Codi, DEGREES OF
COMFORT, H | HYDE LANE, COZYTY, LIFEHUG, TRUSTWARMTH, CHENLANYU, Gasky, Entil,
JETERY, MaxKare, MARNUR, Curecure, Maxkahome, OHSEE, AOSEE, Z3GOGO, QCUQ,
Bedsure, Guohaoi, ydw, dowin, Homemate, JKMAX, blunique, CHRUN, BENFOX,
JOCULAR, Gostery, MAXEVE, Cuouou, RESTCAT, CHICTEX, OUROSE, OKCHILD, TECKELE,
Yokimisu, ESTINGO, CHIOKY, FOCO, STARBEDIA, YANYEA, Longering, Klaggie.
Description Models
The product covered by this report is Heated Throw, for household and indoor
use only, provided with a in-line-cord temperature controller, which equipped
with power supply cord terminating with a 2-wire polarized plug.
LYT1-L, LYT1-F, HMHB-5060a, HMHB-5060b, HMHB-5060c, HMHB-5060p, YHB-R60,
YCDMEB5060.
Model Similarity Refer to Illustration 8 in section 7.
Ratings
120Vac, 60Hz, 105W. 120Vac, 60Hz, 100W.
Other Ratings NA
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product
Photographs
Photo 1 – External view for model LYT1-L
Page 3 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
1a
draft report
Photo 2 – External view for model LYT1-F
1b
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product
Photographs
Photo 3 – Internal View
Page 4 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
2
draft report
Photo 4 – View of Temperature Controller
3
4
5d 5c
5b
5a
5
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product
Photographs
Photo 5 – View of Temperature Controller
Page 5 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
Photo 6 – View of Temperature Controller
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs
Page 6 of 40
Photo 7 – View of PCB of Temperature Controller
5e
5f
5g
5h
5i
5j 5m
Issued: 7-Jul-2023 Revised: 15-Sep-2023
5k
5l
5n
5o
draft report
Photo 8 – View of Connector
6
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product
Photographs
Photo 9 – View of Connector
Page 7 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
Photo 10 – View of Connector
6b 6a 6c 6d
6e 6f 6g
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product
Photographs
Photo 11 – View of Inner Fabric
Page 8 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
9
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs
Page 9 of 40
Photo 12 – View Temperature Controller type LY01A series
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs
Page 10 of 40
Photo 13 – View Temperature Controller type LY01A series
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 3.0 Product
Photographs
Photo 14 – External view of model YHB-R60
Page 11 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
3.0 Product Photographs
Page 12 of 40
Photo 15 – View of Temperature Controller type LY13A
Issued: 7-Jul-2023 Revised: 15-Sep-2023
5
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
4.0 Critical Components Item no.1 Name
Manufacturer/ trademark2
Photo #
1 1a Outer Fabric
Bluetex Health technology Co., Ltd.
2 1b Outer Fabric
Bluetex Health technology Co., Ltd.
1
1c
Outer Fabric (not shown)
Bluetex Health technology Co., Ltd.
draft report
Page 13 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
Type / model2 Nap cloth
Flannel PV Fabric
Technical data and securement means
Mark(s) of conformity
3
The material is 100% polyester
with a weight of 170 g/m² (±10%),
180g/m² (±10%), 190 g/m² (±
10%), 210 g/m² (±10%) or 230
g/m² (±10%). The material creates the top and
NR
bottom layer of the throw
construction and are hemmed and
sewn. Refer to Illustration 5 for
details.
The material is 100% polyester
with a weight of 190 g/m² (±10%),
210 g/m² (±10%), 230 g/m² (±
10%), 220 g/m² (±10%) or 170
g/m² (±10%). The material creates the top and
NR
bottom layer of the throw
construction and are hemmed and
sewn. Refer to Illustration 5 for
details.
The material is 100% polyester
with a weight of 260 g/m² (±10%).
The material creates the top and
bottom layer of the throw
NR
construction and are hemmed and
sewn. Refer to Illustration 5a for
details.
The material is 100% polyester
with a weight of 260 g/m² (±10%).
The material creates the top and
bottom layer of the throw
NR
construction and are hemmed and
sewn. Refer to Illustration 5 for
details.
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 14 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
Photo #
4.0 Critical Components Item no.1 Name
Manufacturer/ trademark2
Type / model2
Technical data and securement means
Mark(s) of conformity
3
3 2 Heater Wire
TOTOKU ELECTRIC CO LTD
10932
4 3 Interconnect Cord Various
4
4
Power Supply Cord Set
4, 15
5
Temperature Controller
Various
Bluetex Health technology Co., Ltd. Bluetex Health technology Co., Ltd.
Bluetex Health technology Co., Ltd.
SPT-2 SPT-2 SPT-2 LY-T-01
LY01A series
LY13A
4 5a Enclosure
CHI MEI CORPORATION
PA-765A(+)
Rated 150V, 105°C, 7 /m, VW-1, 15m in length, thermoplastic insulated heater/sensor wires. Refer to Illustration 5, 6 for details.
cURus
Rated 150V, 105°C, 5.6 /m for first resistance wire and 5/m for second resistance wire, VW-1, thermoplastic insulated heater/sensor wires. Refer to Illustration 5a, 6a for details. Rated 18AWG x 3C, 300V, VW-1, 105°C. Molded with a strain relief Rated 20AWG x 3C, 300V, VW-1, 105°C. Molded with a strain relief Rated 18AWG x 2C, rated 300 V, VW-1, 105 °C. Provided with a
cURus
cULus cETLus cULus cETLus cULus cETLus
Rated 120V, 60Hz, 105W. Consists of item 5a thru 5o.
See 5.0 See 5.0
Rated 120V, 60Hz, 105W. Consists of item 5a thru 5o.
NR
ABS material. Rated V-0, HWI=3, HAI=0, CTI=1, 80°C. Measured 2.0mm thick minimum. Upper and lower parts provided, secured together by screws.
cURus
draft report
4 5b Switch Button 4 5c LED Cover 4 5d Cord Bushing
CHI MEI CORPORATION
PA-765A(+)
FORMOSA PLASTICS CORP
FM090
POLYONE CORP 6602(f1)
ABS material. Rated V-1, 80°C. Measured 1.5mm thick minimum.
POM material. Rated HB, 90ºC, Min. 1.5mm thick. PVC material. Rated V-0,
HWI-2, HAI=0, CTI=0, 105°C. Measured 1.5mm thick minimum.
cURus cURus cURus
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 15 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
Photo #
4.0 Critical Components Item no.1 Name
7 5e Current Fuse 7 5f Varistor 7 5g X2 Capacitor 7 5h Resistor
7 5i Thermal link 7 5j Capacitor 7 5k Resistor 7 5l Resistor 7 5m Triac 7 5n
IC
7 5o PCB
8
6
Connector Assembly
10
6a
Male Connector Securement
10
6b
Male Throw Connector
10 6c Connector PCB
10
6d
Male Connector Terminals
draft report
Manufacturer/ trademark2
Various Various Various
Various
Type / model2
Various 7D241K 7D391K
Various
Various
XIAMEN SET ELECTRONICS CO LTD Various
Various
Various
H1 Various Various
Various
Various
Various
BT136
Cmsemicon
CMS89F113
Various
Various
Bluetex Health technology Co., Ltd.
LY-01
Various
Various
TEIJIN CHEMICALS PLASTIC COMPOUNDS SHANGHAI LTD
LN-2520(##)
Various
Various
Various
Various
Technical data and securement means
F1. Rated 3.15A, 250VAC VR1. Rated 150VAC, 240VDC. VR1. Rated 250VAC, 390VDC.
(CX1). Rated 275VAC 0.1uF, T100 (R12, R16). Oxide film resistor. Rated 2K ohm,
1W.
Mark(s) of conformity
3
cURus cURus cURus
cURus
NR
Rated 2A 250VAC, Tf=102°C.
cURus
(C1). Rated 400V, 1uF. (R3). Oxide film resistor. Rated 100 ohm, 1W. (R6). Metal oxide film resistor. Rated 0.33 ohm, 1W. (T1). Each rated 600V, 4A, Tj=125 °C. (U1). 16 pin. Software Checksum: AB91. Rated V-0, 130 °C, met UL796. Measured 1.6 ± 0.1mm thick minimum. Secured to Enclosure by screws. Rated 120V, 60Hz, 1.5A. Consisted following items 6a thru 6g: Secured by stitching through the top and bottom layer, and through the reinforcement patch. Buttonhole is sewn through the reinforcement patch and material. Stitching also runs through all layers for approx. one inch along the top of the “T” shaped connector. The reinforcement patch consists of one layer of 100% non-woven polyester material.
NR NR NR NR NR UR See 5.0
NR
PC material, rated V-0, HWI=3, HAI=0, CTI=2, 125°C. Measured 1.5mm thick minimum.
cURus
Rated V-0, 130°C, secured within
connector enclosure with integral
UR
tabs.
3 provided. Tinned copper, shaped as shown.
NR
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 16 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
Photo #
4.0 Critical Components Item no.1 Name
Manufacturer/ trademark2
Type / model2
10
6e
Female Cover
Connector
POLYONE
CORP
6602(f1)
TEIJIN
10
6f
Female Connector Enclosure
CHEMICALS PLASTIC COMPOUNDS
LN-2520(##)
SHANGHAI LTD
10
6g
Female Connector Terminals
Various
Various
Technical data and securement means
Mark(s) of conformity
3
PVC material. Rated V-0, HWI=2, HAI=0, 105°C. PVC tube added for additional strain relief.
cURus
PC material, rated V-0, HWI=3, HAI=0, CTI=2, 125°C. Measured 1.5mm thick minimum.
cURus
3 provided. Clear plated brass.
NR
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 17 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
Photo #
4.0 Critical Components Item no.1 Name
Manufacturer/ trademark2
Type / model2
Technical data and securement means
Mark(s) of conformity
3
Rating/Washing/
1
7
Warning Label on Blanket (not
Various
shown)
Various
100% polyester, 100 g/m2. Permanent ink printing directly on the label by silk screening, and all NR the four edges were secured by stitching.
Label on
1
8
Temperature Controller (not
shown)
Various
Various
Rated 80°C and suitable for ABS
material. Molding, stamping, silk-
UR
screen are all acceptable.
11 9 Inner Fabric
Bluetex Health technology Co., Ltd.
Non-woven
For Model LYT1-F, HMHB-5060b,
HMHB-5060c, HMHB-5060p. The material is 100% polyester with a
NR
weight of 40 g/m² (±10%).
NOTES:
-
Not all item numbers are indicated (called out) in the photos, as their location is obvious.
-
“Various” means any type, from any manufacturer that complies with the “Technical data and securement means” and meets the “Mark(s) of conformity” can be used.
-
Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. “NR” – indicates Unlisted and only visual examination is necessary. “See 5.0″ indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
5.0 Critical Unlisted CEC Components
Page 18 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
SUBASSEMBLY Photo # Item no. Name
Manufacturer/Trademark Type / model
4, 15
5
Temperature Controller
Bluetex Health technology Co., Ltd.
LY-T-01
Electrical Rating:
Rated 120V, 60Hz, 105W
Insulation class NA
Component Standard used:
UL 60730-1:2016 Ed.5 & UL 60730-2-9:2017 Ed.4 CSA E60730-1:2015, Ed.5 & CSA E60730-2-9:2015 Ed.3
COMPONENTS LIST (refer to illustration 3 and 4 for assembly drawing)
Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no.
4
5a
4
5b
4
5c
4
5d
7
5e
7
5f
7
5g
7
5h
7
5i
7
5j
7
5k
7
5l
7
5m
7
5n
7
5o
VERIFICATION PROCESS Frequency: Annual
Test Name Verify Construction
Test Site: CEC
Number of samples to test: 1
Test Parameters
Per the component descriptions noted above
SUBASSEMBLY
Photo # Item no. Name
Manufacturer/Trademark Type / model
8
6
Connector Assembly
Bluetex Health technology Co., Ltd.
LY-01
Electrical Rating:
120V, 60Hz, 1.5A
Insulation class NA
Component Standard used:
UL 1977:2016 Ed.3+R:17Nov2020 CSA C22.2#182.3:2016 Ed.2+U1
COMPONENTS LIST (refer to illustration 7 for assembly drawing)
Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no.
10
6a
10
6b
10
6c
10
6d
10
6e
10
6f
10
6g
draft report
VERIFICATION PROCESS Frequency: Annual
Test Name Verify Construction
Test Site: CEC
Number of samples to test: 1
Test Parameters
Per the component descriptions noted above
SUBASSEMBLY Photo # Item no. Name
Manufacturer/Trademark Type / model
4, 15
5
Temperature Controller
Bluetex Health technology Co., Ltd.
LY01A series
Electrical Rating:
Rated 120V, 60Hz, 105W
Insulation class NA
Component Standard used:
UL 60730-1:2016 Ed.5 & UL 60730-2-9:2017 Ed.4 CSA E60730-1:2015, Ed.5 & CSA E60730-2-9:2015 Ed.3
COMPONENTS LIST (refer to illustration 3 and 4a for assembly drawing)
Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no. Photo # Item no.
4
5a
4
5b
4
5c
4
5d
7
5e
7
5f
7
5g
7
5h
7
5i
7
5j
7
5k
7
5l
7
5m
7
5n
7
5o
VERIFICATION PROCESS Frequency: Annual
Test Name Verify Construction
Test Site: CEC
Number of samples to test: 1
Test Parameters
Per the component descriptions noted above
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 19 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
6.0 Critical Features Recognized Component – A component part, which has been previously evaluated by an accredited certification
body with restrictions and must be evaluated as part of the basic product
considering the restrictions as specified by the Conditions of Acceptability.
Listed Component – A component part, which has been previously Listed or
Certified by an accredited Certification Organization with no restrictions and
is used in the intended application within its ratings.
Unlisted Component – A part that has not been previously evaluated to the
appropriate designated component standard. It may also be a Listed or
Recognized component that is being used outside of its evaluated Listing or
component recognition.
Critical Features/Components – An essential part, material, subassembly,
system, software, or accessory of a product that has a direct bearing on the
product’s conformance to applicable requirements of the product standard.
Construction Details – For specific construction details, reference should be
made to the photographs and descriptions. All dimensions are approximate
unless specified as exact or within a tolerance. In addition to the specific
construction details described in this Report, the following general
requirements also apply.
1. Spacing – In primary circuits Min. 1.6 mm are maintained through air and
over surfaces of insulating material between current-carrying parts of
opposite polarity and between bare live part and other non-current-carrying
conductive parts. Min. 3.2 mm between bare live parts and an electrically
conductive enclosure.
2. Mechanical Assembly – Components such as switches, fuseholders,
connectors, wiring terminals and display lamps are mounted and prevented from
shifting or rotating by the use of lockwashers, starwashers, or other mounting
format that prevents turning of the component.
3. Corrosion Protection – All ferrous metal parts are protected against
corrosion by painting, plating or the equivalent.
4. Accessibility of Live Parts – All uninsulated live parts in primary
circuitry are housed within a metal enclosure constructed with no openings
other than those specifically described in Sections 4 and 5.
5. Polarized Connection – This product is provided with a polarized power
supply connection. All single pole switches and fuses are connected only to
the ungrounded supply circuit conductor.
6. Internal Wiring – Internal wiring is routed away from sharp or moving
parts. Internal wiring leads terminating in soldered connections are made
mechanically secure prior to soldering. Recognized Component separable (quick
disconnect) connectors of the positive detent type, closed loop connectors, or
other types specifically described in the text of this report are also
acceptable as internal wiring terminals. At points where internal wiring
passes through metal walls or partitions, the wiring insulation is protected
against abrasion or damage by plastic bushings or grommets.
7. Schematics – Refer to Illustration 3 for schematics requiring verification
during Field Representative Inspection Audits.
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 20 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
6.0 Critical Features 8. Markings – The product is marked on a labeling system
as described in item no.7 and 8 of section 4.0 or by
molding, or by silk-screen as follows: – applicant’s name or brand name –
model number – electrical ratings (volts, input current & frequency) – date of
manufacturing
9. Cautionary Markings – Refer to Illustration 1 for layouts.
10. Installation, Operating and Safety Instructions – Instructions for
installation and use of this product are provided by the manufacturer as
required by the standard. – For the separate hard card, material, instruction
sheet or instruction booklet that is packed with the bedding, IMPORTANT
INSTRUCTIONS DO NOT DESTROY, or the equivalent, in letters not less than 3/8
inch (9.5 mm) high. – The letter of contents was: for upper case letter, 3.2
mm high min., for lower case letter, 1.6 mm high min. – Refer to Illustration
2, 2a, 2b for details. – The instruction manual should be packed with the
bedding.
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
7.0 Illustrations Illustration 1 – Cautionary Marking
Page 21 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
Notes: 1) For upper case letters 3.2 mm high min., for lower case letters 1.6
mm high min.
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 2 – Instruction Manual
Page 22 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 2a – Instruction Manual
Page 23 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 2b – Instruction Manual
Page 24 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 3 – Circuit Diagram
Page 25 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 4 – PCB layout
Page 26 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
7.0 Illustrations
Page 27 of 40
Illustration 4a – PCB layout of Temperature Controller type LY01A series
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 28 of 40
7.0 Illustrations
Illustration 5 – Wiring diagram for heating wire
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
7.0 Illustrations
Page 29 of 40
Illustration 5a – Wiring diagram for heating wire of model YHB-R60
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 6 – Drawing of heater wire
Page 30 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 6a – Drawing of heater wire
Page 31 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 7 – Drawing of Connector
Page 32 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd 7.0
Illustrations
Illustration 8 – Model Similarity
Page 33 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
Model
Rated Power
Controller type
Controller quatity
Heater Size (inch) wire
length
LYT1-L LYT1-F
LY-T-01
HMHB5060a
HMHB5060b
105W LY01A
HMHB5060c
1
50”*60” 15 m
HMHB5060p
YCDMEB5060
LY13A
YHB-R60 100W LY01A-A
1
Ø60
21M
draft report
Heater wire resistance
R: 7.0 /m S: 7.0 /m
R: 5.6 /m S: 5.0 /m
Outer Fabric
Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%).
Flannel 190 g/m² (± 10%).
Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%) Flannel 190 g/m² (± 10%) or 210 g/m² (±
10%) Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%).
Flannel 190 g/m² (± 10%) or 230 g/m² (±
10%)
Nap cloth 180 g/m² (±10%)
PV Fabric 260 g/m² (±10%)
Flannel 190 g/m² (± 10%)
Nap cloth 170 g/m² (±10%) or 190 g/m²
(±10%).
Flannel 190 g/m² (± 10%) or 220 g/m² (±
10%)
Same as HMHB5060a, HMHB5060b, HMHB5060c, HMHB5060p, YHB-R60
Flannel 260 g/m² (± 10%)
Note: 1. Controller type LY01A-A and LY01A are similar, except model signation. 2. Controller type LY13A and LY01A are similar, except model signation and appearance.
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 34 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
8.0 Test Summary
Evaluation Period 22-May-2023 ~ 7-Jul-2023
Project No. 230522230GZU
Sample Rec. Date 22-May-2023
Condition Prototype
Sample
ID.
S230522230001~003
Test Location Test Procedure
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch Address:
Room101/301/401/102/202/302/402/502/602/702/802, No. 7-2, Caipin Road, Huangpu
District, Guangzhou, Guangdong, China
Testing Lab
Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria.
Due to the previous testing performed under Intertek Report 190410076GZU-001, only the following testing was performed:
UL 964:2011
CSA
UL 746C:2018
Test Description
Ed.12+R:05Jun20 C22.2#101:2017 Ed.7 +
–
15
Ed.3
R:01Sep2021
Clause
Clause
Clause
Control Impact and Calibration
17
–
–
–
Resistance to Impact Test
–
–
56
–
8.1 Signatures
A representative sample of the product covered by this report has been evaluated and found to comply with the
applicable requirements of the standards indicated in Section 1.0.
Completed by:
Ming Yuan
Reviewed by:
Oliver Guo
Title:
Engineer
Title:
Senior Project Engineer
Signature:
Signature on file
Signature:
Signature on file
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 35 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
9.0 Correlation Page For Multiple Listings The following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.
BASIC LISTEE Bluetex Health technology Co.,Ltd
Address
No. 88, South of Qisheng Road, PaojiangYuecheng District, Shaoxing City Zhejiang Province 312000
Country Product
China Heated Throw
MULTIPLE LISTEE 1 Address Country
Brand Name
None
ASSOCIATED MANUFACTURER
Address Country
MULTIPLE LISTEE 1 MODELS
BASIC LISTEE MODELS
draft report
MULTIPLE LISTEE 2 Address Country
Brand Name
None
ASSOCIATED MANUFACTURER
Address Country
MULTIPLE LISTEE 2 MODELS
BASIC LISTEE MODELS
MULTIPLE LISTEE 3 Address Country
Brand Name
None
ASSOCIATED MANUFACTURER
Address Country
MULTIPLE LISTEE 3 MODELS
BASIC LISTEE MODELS
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 36 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
10.0 General Information The Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials.
COMPONENTS Components used shall be those itemized in this Intertek report covering the product, including any amendments
LISTING MARK The ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek.
The mark must include the following four items:
- applicable country identifiers “US” and/or “C” or “US”, “C” and “EU” 2) the word “Listed” or “Classified” or “Recognized Component” (whichever is appropriate) 3) a control number issued by Intertek 4) a product descriptor that identifies the standards used for certification. Example:
For US standards, the words, “Conforms to” shall appear with the standard number along with the word, ” Standard” or “Std.” Example: “Conforms to ANSI/UL Std. XX.”
For Canadian standards, the words “Certified to CAN/CSA Standard CXX No. XX.” shall be used, or abbreviated, “Cert. to CAN/CSA Std. CXX No. XX.”
Can be used together when both standards are used.
If all standards on the ATM have the same standard title, the shared title or its abbreviation may be used in place of the examples above. Example: “Medical Electrical Equipment” or “MEE”; “Information Technology Equipment” or “ITE”; “Audio/Video Information And Communication Technology Equipment” or “A/V ICTE”.
Note: A facsimile must be submitted to Intertek, Attn: Follow-up Services for approval prior to use. The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory assessment in your facility.
draft report
MANUFACTURING AND PRODUCTION TESTS Manufacturing and Production Tests shall be
performed as required in this Report.
FOLLOW-UP SERVICE Periodic unannounced audits of the manufacturing facility
(and any locations authorized to apply the mark) shall be scheduled by
Intertek. An audit report shall be issued after each visit. Special attention
will be given to the following:
1. Conformance of the manufactured product to the descriptions in this
Report. 2. Conformance of the use of the ETL mark with the requirements of
this Report and the Certification Agreement. 3. Manufacturing changes. 4.
Performance of specified Manufacturing and Production Tests.
In the event that the Intertek representative identifies non-conformance(s) to
any provision of this Report, the Applicant shall take one or more of the
following actions:
1. Correct the non-conformance. 2. Remove the ETL Mark from non-conforming
product. 3. Contact the issuing product safety evaluation center for
instructions.
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 37 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
10.1 Evaluation of Unlisted Components Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated.
The Applicant will be notified, in writing, via the applicable contact methods, as defined in Section 1.0, when these components must be selected and sent to Component Evaluation Center (CEC) for reevaluation.
Due to particular testing requirements, some components may be requested to be shipped to specific labs. Thus, specific shipment destination(s) for each sample will be provided in the written notification.
Managing CEC Location: Intertek Testing Services Shenzhen Limited Guangzhou Branch ETL Component Evaluation Center Room 101/301/401/102/202/302/402/502/602/702/802, No. 7-2, Caipin Road, Huangpu Guangzhou, Guangdong, China Attn: Ms. Joey Kuang Sample Disposition: Due to the destructive nature of the testing, all samples will be discarded at the conclusion of testing unless, the manufacturer specifically requests the return of the samples. The request for return must accompany the initial component shipment.
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 38 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
11.0 Manufacturing and Production Tests The manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:
Required Tests
– Dielectric Voltage Withstand Test – Polarization Continuity Check Test
draft report
11.1 Dielectric Voltage Withstand Test Method One hundred percent of
production of the products covered by this Report shall be subjected to a
routine production line dielectric withstand test. The test shall be conducted
on products, which are fully assembled. Prior to applying the test potential,
all switches, contractors, relays, etc., should be closed so that all primary
circuits are energized by the test potential. If all primary circuits cannot
be tested at one time, then separate applications of the test potential shall
be made.
The test voltage specified below shall be applied between primary circuits and
accessible dead-metal parts. The test voltage may be gradually increased to
the specified value but must be maintained at the specified value for one
second or one minute as required.
Test Equipment The test equipment is to have the following features and
characteristics: a) A means of indicating the test voltage that is being
applied to the appliance under test. This may be accomplished by sensing the
voltage at the test leads or by an equivalent means.
b) An output voltage that: 1) Has a sinusoidal waveform; 2) Has a frequency
that is within the range of 40 70 Hz; and 3) Has a peak value of the
waveform that is not to be less than 1.3 and not more than 1.5 times the
rootmean-square value.
c) A means of effectively indicating unacceptable performance. The indication
is to be: 1) Auditory if it can be readily heard above the background noise
level; 2) Visual if it commands the attention of the operator; or 3) A device
that automatically rejects an unacceptable product. If the indication of
unacceptable performance is auditory or visual, the indication is to remain
active and conspicuous until the test equipment is reset manually.
d) When the test equipment is adjusted to produce the test voltage and a
resistance of 120,000 ohms is connected across the output, the test equipment
is to indicate an unacceptable performance within 0.5 second. A resistance of
more than 120,000 ohms may be used to produce an indication of unacceptable
performance, if the manufacturer elects to use a tester having higher
sensitivity.
Exception: The sensitivity of the test equipment may be reduced, a lower value
of resistance may be used, when testing an appliance intended to be
permanently wired.
Products Requiring Dielectric Voltage Withstand Test: Product All products covered by this Report.
Test Voltage 1240 V or 1480 V
Test Time 60 s 1 s
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 39 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
11.2 Polarization Continuity Check Test Method Each appliance shall be
examined or tested for electrical continuity between the ungrounded circuit
supply conductor of the attachment plug (narrower blade of the 2-wire plug),
and the line switch and the control unit (if provided).
Test Equipment Any indicating device, such as an ohmmeter, a battery and
buzzer combination, or the like, may be used to determine continuity.
Products Requiring Polarization Continuity Check Test: Product All products
covered by this Report.
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Report No. 230522230GZU-001 Bluetex Health technology Co.,Ltd
Page 40 of 40
Issued: 7-Jul-2023 Revised: 15-Sep-2023
12.0 Revision Summary
The following changes are in compliance with the declaration of Section 8.1:
Date/
Project Handler/
Proj # Site ID Reviewer
Section Item Description of Change
15-Sep-2023 Seraph Wei
2.0
–
Added new brand names FOCO, STARBEDIA, YANYEA, Longering and Klaggie.
230913188GZU Oliver Guo
draft report
ED 16.3.15 (1-Jul-2022) Mandatory
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>