FLEXTHERM HHGGS2S4204L00L030131 Surface XL Green Cable Owner’s Manual
- August 13, 2024
- FLEXTHERM
Table of Contents
**FLEXTHERM HHGGS2S4204L00L030131 Surface XL Green Cable Owner’s Manual
**
OUTSTANDING FLEXIBILITY
With its constant diameter at every length, the Green Cable Surface XLTM is not only the perfect complement to uncoupling membrane installation systems, but it can also be installed with traditional gauges.
-
EASY TO INSTALL
-
FLEXIBLE AND ROBUST CABLE WITH MINIMAL SHAPE MEMORY
-
ADAPTS TO ROOMS OF ALL SHAPES AND SIZES
-
MAINTENANCE FREE
-
ENERGY SAVINGS:
A HEATED MASS RETAINS HEAT MORE EASILY THAN AIR -
CAN BE INSTALLED INDOORS IN DRY OR WET ENVIRONMENTS
-
COMPLETE SET, INCLUDING:
HEATING CABLE, CABLE GAUGES,
HOT GLUE STICKS, AND INSTALLATION GUIDE
IDEAL FOR:
bathroom, kitchen, living room, bedroom, basement, hallway, day care centre, locker room, small space
MANUFACTURING
- Heating elements covered with fluoropolymer insulation for greater reliability
- Paired and twisted dual conductor design to eliminate electromagnetic fields
- Conductors shielded with a copper braid to ensure safety and robustness
- Flexible PVC sheath with constant diameter for easy installation
AVAILABLE VOLTAGES
- 120 V and 240 V
POWERS
- Cable gauges
- 3 in.: 14.5 W/ft2
- Alternated 3-4 in.: 12.4 W/ft2
- 4 in.: 10.9 W/ft2
- Uncoupling membrane
- Alternated 2-3 studs (2-1/2 – 3-3/4 in.): 13.8 W/ft2
- 3 studs (3-3/4 in.): 11.5 W/ft
CONTROL
- Electronic thermostat for floor heating (sold separately)
INSTALLATION
- Installs in a few easy steps with an uncoupling membrane or the included patented cable spacers
- Compatible with all subfloors that accept thinset mortar or self-levelingunderlayment
- Compatible with most floor coverings (Validate installation details with the flooring manufacturer)
- Can be installed in a wet environment, such as a European style shower floor
INSTALLATION SYSTEM
UNCOUPLING MEMBRANE
GAUGES
TECHNICAL SPECIFICATIONS
Volts| Part No.| COVERAGE (FT²)| **Wattage* (W)|
Amperage (A)| Length (ft)
---|---|---|---|---|---
Stelpro membrane| Other membrane| Cable gauges
2 1/2’’- 3 3/4’’**
Alternate 2 – 3
Studs
13.8 W/ft 2
| 3 3/4’’
3
Studs
11.5 W/ft 2
| 2 3/8’’- 3 1/2’’
Alternate 2 – 3
Studs
14.4 W/ft 2
| 3 1/2’’
3
Studs 12 W/ft 2
| 3’ 14.5| W/ft 2| 3’’ – 4’’
Alternate
12.4 W/ft 2
| 4’’ 10.9 W/ft 2
240 V / 208 V| HGS240L0031| 9.1| 10.8| 8.8| 10.5|
8.8| | 10.1| 11.5| 113 / 85| 0.5 / 0.4| 31
HGS240L0049| 13.9| 16.6| 13.4| 16.0| 13.| 4| 15.5| 17.6| 176 / 132| 0.8
/ 0.7| 49
HGS240L0063| 17.8| 21.2| 17.1| 20.5| 17| .1| 19.8| 22.6| 228 / 171| 1.0
/ 0.9| 63
HGS240L0089| 24.8| 29.6| 23.9| 28.7| 23| .9| 27.7| 31.5| 322 / 242| 1.4
/ 1.2| 89
HGS240L0111| 30.8| 36.8| 29.6| 35.6| 29| .6| 34.4| 39.1| 403 / 303| 1.7
/ 1.5| 111
HGS240L0134| 36.8| 44.0| 35.4| 42.5| 35.| 4| 41.1| 46.8| 484 / 364| 2.1
/ 1.8| 134
HGS240L0157| 43.1| 51.5| 41.5| 49.9| 41| .5| 48.2| 54.9| 570 / 428| 2.4
/ 2.1| 157
HGS240L0178| 48.6| 58.1| 46.7| 56.2| 46| .7| 54.3| 61.9| 645 / 484| 2.7
/ 2.4| 178
HGS240L0200| 54.6| 65.2| 52.5| 63.1| 52| .5| 61.0| 69.5| 725 / 545| 3.1
/ 2.7| 200
HGS240L0222| 60.5| 72.3| 58.1| 70.0| 58| .1| 67.6| 77.0| 806 / 605| 3.4
/ 3.0| 222
HGS240L0258| 69.9| 83.6| 67.2| 80.9| 67.| 2| 78.1| 89.1| 934 / 702| 3.9
/ 3.4| 258
HGS240L0291| 78.7| 94.1| 75.6| 91.0| 75| .6| 87.9| 100.3| 1054 / 792|
4.4 / 3.9| 291
HGS240L0320| 86.4| 103.3| 83.0| 100.0| 83.| 0| 96.6| 110.1| 1159 / 871|
4.9 / 4.2| 320
HGS240L0352| 95.0| 113.6| 91.2| 109.9| 91.| 2| 106.1| 121.1| 1276 / 958|
5.4 / 4.7| 352
HGS240L0390| 105.0| 125.6| 100.9| 121.5 0| 100| .9| 117.4| 133.9|
1413 / 1062| 5.9 / 5.1| 390
HGS240L0418| 112.4| 134.4| 107.9| 130.0| 10| 7.9| 125.6| 143.3| 1515 /
1138| 6.4 / 5.5| 418
HGS240L0480| 128.8| 154.2| 123.7| 149.1| 12| 3.7| 144.0| 164.3| 1739 /
1306| 7.3 / 6.3| 480
HGS240L0503| 134.8| 161.4| 129.5| 156.1| 12| 9.5| 150.8| 172.0 2|
1760 / 1322| 7.4 / 6.4| 503
HGS240L0553| 148.0| 177.2| 142.2| 171.4| 14| 2.2| 165.5| 188.9| 2109 /
1584| 8.8 / 7.7| 553
HGS240L0632| 168.9| 202.2| 162.2| 195.6| 16| 2.2 8| 188.9| 215.5|
2234 / 1678| 9.4 / 8.1| 632
HGS240L0712| 189.9| 227.5| 182.4| 220.0| 18| 2.4| 212.5| 242.4| 2438 /
1831| 10.2 / 8.8| 712
HGS240L0772| 205.7| 246.4| 197.6| 238.2| 19| 7.6| 230.1| 262.6| 2796 /
2100| 11.7 / 10.1| 772
HGS240L0908| 241.5| 289.3| 232.0| 279.7| 23| 2.0 0| 270.2| 308.4|
3289 / 2470| 13.7 / 11.9| 908
120 V| HGS120L0024| 7.2| 8.6| 6.9| 8.3| 6| .9| 8.0| 9.1| 88|
0.8| 24
HGS120L0031| 9.2| 10.9| 8.9| 10.6| 8| .9| 10.2| 11.6| 114| 1.0| 31
HGS120L0045| 12.8| 15.2| 12.3| 14.7| 12.| 3| 14.3| 16.2| 161| 1.4| 45
HGS120L0067| 18.9| 22.5| 18.1| 21.7| 18| .1| 21.0| 23.9| 242| 2.1| 67
HGS120L0079| 22.0| 26.3| 21.2| 25.4| 21.| 2| . 24.6| 28.0| 285|
2.4| 79
HGS120L0100| 27.8| 33.2| 26.8| 32.1| 26| .8| 31.1| 35.4| 363| 3.1| 100
HGS120L0111| 30.8| 36.8| 29.6| 35.6| 29| .6| 34.4| 39.1| 403| 3.4| 111
HGS120L0129| 35.6| 42.5| 34.2| 41.1| 34.| 2| 39.7| 45.2| 467| 3.9| 129
HGS120L0160| 43.9| 52.4| 42.2| 50.7| 42.| 2| 49.0| 55.8| 579| 4.9| 160
HGS120L0176| 48.2| 57.5| 46.3| 55.7| 46.| 3| 53.8| 61.3| 638| 5.4| 176
HGS120L0195| 53.2| 63.5| 51.2| 61.5| 51| .1| 59.4| 67.7| 707| 5.9| 195
HGS120L0209| 56.9| 68.0| 54.7| 65.8| 54| .7| 63.6| 72.5| 758| 6.4| 209
HGS120L0240| 65.2| 78.0| 62.7| 75.4| 62.| 7| 72.9| 83.1| 870| 7.3| 240
HGS120L0252| 68.3| 81.7| 65.6| 79.0| 65| .6| . 76.3| 87.0| 879|
7.4| 252
HGS120L0276| 74.9| 89.5| 71.9| 86.6| 71| .9| 83.7| 95.4| 1054| 8.8| 276
HGS120L0316| 85.3| 102.1| 82.0| 98.7| 82| .0| 95.4| 108.8| 1118| 9.4|
316
HGS120L0356| 96.0| 114.8| 92.2| 111.0| 92.| 2| 107.3| 122.3| 1218| 10.2|
356
HGS120L0386| 103.9| 124.3| 99.8| 120.2| 99| .8| 116.1| 132.4| 1398|
11.7| 386
HGS120L0454| 121.8| 145.8| 117.0| 141.0| 11| 7.0| 136.2| 155.4| 1645|
13.7| 454
*240-volt models can be connected to a 208-volt source, but the heating capacity will be reduced to approximately 75% of the indicated value.
ACCESSORIES
Part No | Description |
---|---|
HGSMD162 | STELPRO – Uncoupling membrane (roll of 162 ft²) |
HGSMD054 | STELPRO – Uncoupling membrane (roll of 54 ft²) |
HGSMDF | STELPRO – Uncoupling membrane (sheet of 8.9 ft²) |
HGSGG | STELPRO – Gauges for heating cable (pack of 20), includes glue stick |
FLS1240 | STELPRO-10K Thermal floor sensor – 15 ft wire |
FL625 | STELPRO Hot Glue Sticks (25 units) |
FSK 03 | STELPRO – Repair kit (for 1 splice) – Twin conductor surface cable |
(GS, HGS, CGS, CPS, TS)
WARRANTY
Twenty-five years
Flextherm reserves the right to modify descriptions, manufacturing
specifications or prices without prior notice.
For all the latest models and prices, please refer to our website at
www.flextherm.com.
*We offer a limited lifetime warranty on Green Cable Surface XLTM when installed by a certified FLEXpert. Certain conditions apply.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>