Osaki OP-4D Solis Massage Chair User Manual

June 17, 2024
Osaki

USER MANUAL
OP-4D SOLIS Massage Chair

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following:
Read all instructions before using Massage chair.
DANGER — To reduce the risk of electric shock:

  1. Always unplug this appliance from the electrical outlet immediately after using and before cleaning.
  2. Never use pins or other metallic fasteners with this appliance.
  3. Carefully examine the covering before each use. Discard the appliance if the covering shows any sign of deterioration, such as checking, blistering, or cracking.
  4. Keep Dry — Do not operate in a wet or moist condition.

WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons:

  1. An appliance should never be left unattended when plugged in. Unplug from outlet when not in use, and before putting on or taking off parts.

  2. Do not operate under blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons.

  3. Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled persons.

  4. Use this appliance only for its intended use as described in this manual. Do not use attach- ments not recommended by the manufacturer.

  5. Never operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a service center for examination and repair.

  6. Do not carry this appliance by supply cord or use cord as a handle.

  7. Keep the cord away from heated surfaces.

  8. Never operate the appliance with the air openings blocked. Keep the air openings free of lint, hair, and the like.

  9. Never drop or insert any object into any opening.

  10. Do not use outdoors.

  11. Do not operate where aerosol (spray) products are being used or where oxygen is being administered.

  12. To disconnect, turn all controls to the off position, then remove plug from outlet.

  13. Temperatures sufficiently high to cause burns may occur regardless of the control setting. Do not use on an infant or invalid or on a sleeping or unconscious person.
    Do not use on insensitive skin or on a person with poor blood circulation. Check the skin in contact with the heated area of the appliance frequently to reduce the risk of blistering.

  14. Do Not Crush — Avoid sharp folds.

  15. Keep children away from extended foot support (or other similar parts).

  16. Connect this appliance to a properly grounded outlet only. See Grounding Instructions.

  17. Do not use massager in close proximity to loose clothing or jewelry.

  18. Keep long hair away from massager while in use.

SAVE THESE INSTRUCTIONS GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER — Improper connection of the equipment-grounding conductor can result ina risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product
— if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This product is for use on a nominal 120-V circuit and has a grounding plug that looks like the plug illustrated in sketch A in Figure 1. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product.

RF exposure statement
This equipment complies with the FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
FCC Warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interfer- ence received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Bluetooth link
Turn on Bluetooth of mobile phone, click search, find Bluetooth name is Bluetooth name :MusicStation xxx.

Product Specifications

Product Name Massage Chair
Model OP-4D SOLIS
Power Input 110-120V~, 60Hz
Auto Timer 15 mins
Power Consumption 200W
Product Weight Approx.259.5lbs
Unit 1Box
Product Dimension 63(L) x 30.3(W) x 47.2(H)inches
Maximum Body Weight of User 352Ibs

Side ViewOsaki OP 4D Solis Massage Chair -
Description Side viewOsaki OP 4D Solis Massage
Chair - Description 1 Internal PartsOsaki OP 4D
Solis Massage Chair - Description 2

Preparation For Use

  1. Remove the package and take out the chair and spare parts 1) Remove the carton. Take out the chair.
  1. Install the pillow and backrest cover.
  1. Place the chair in an open area – Allow sufficient space around the chair for reclining purposes.
    – To avoid damage to the floor and to reduce noise, please put a rug under the chair.
    – Make sure that there is no barrier at the front and the back of the chair.
    – Please do not put the chair on wet or uneven floor.
    – To avoid signal interference, please place the chair 1 meter away from TV and radio.
    – Do not expose the chair to direct sunlight or a high temperature place. Otherwise its leather may fade or harden.
    Warning:
    Do not put the power cord under the chair! Be ware of damaging the power cord while moving the chair!

  2. Move the chair 1) As illustrated, push the backrest downwards and tilt chair on to its wheels at a 45° angle.

  1. Slowly push and move the chair to the desired location.
  2. Lower the chair slowly and smoothly until it is fully flat on the ground.
    Warning:
    – Before moving the chair, adjust the footrest back to its original position.
    – Do not move the chair when occupied or in use.
    – Moving the chair may cause damage to the floor.
    Floor potection is recommended (e.g. rugs or carpet).
    – Do not drop or suddenly let go of the chair while moving as it may damage the chair.
    – Two persons are recommended when moving the chair and extra care is required.

Installation Instructions

  1. Control Panel Installations
    Take The Tablet Controller And Pass The Tablet Controller Line Through The Elastic Bag (2) Under The Air Bag Blade In Turn.
    Insert Into The Usb Terminal At The Bottom Of The Chair, And Finally Insert The Tablet Controller Bracket Into The Base, And The Tablet Controller Is Installed.Osaki OP 4D Solis Massage Chair - Preparation
2

  2. Cloak Installations
    Take out the cloak, first disassemble the D button on the head of the chair, and then remove the central ribbon between the head of the cloak and the head of the chair. Assemble with a D-buckle and zip up at last. The assembly of the mantle seat is the same as above.Osaki OP 4D Solis Massage Chair -
Preparation 3Leg Installations

  1. Open the box, slowly take out the massage chair and lower legs, and check whether the installation accessories are completeOsaki OP 4D Solis Massage
Chair - Preparation 42) Place the shank movable shaft in the slot, then install the leg press and tighten the cross screws with the appropriate toolOsaki OP 4D Solis Massage Chair - Preparation
53) Install Leg Link ShaftOsaki OP 4D Solis Massage
Chair - Preparation 64) Connect The Female connector To The Air PipeOsaki OP 4D Solis Massage Chair - Preparation
7

Control Panel

  1. Remote Controller DescriptionOsaki OP 4D Solis Massage Chair - Preparation 81.1 Main MenuOsaki OP 4D Solis Massage Chair - Preparation 9

  2. Auto Mode

  3. Manual Mode

  4. Airbag Massage

  5. Zero Gravity

  6. 0thers

  7. System Settings

1.2 Auto Mode

  1. Full Body Relaxation

  2. Chinese Massage

  3. Japanese Massage

  4. Handstand Stretch

  5. Lay Down To Sleep

  6. Super Stretch

  7. Man Healthcare Mode

  8. Woman Healthcare Mode

  9. Elderly Healthcare Mode

  10. Alignment Mode

  11. Neck& Shoulder Massage Mode

  12. Waist& Hip Massage Mode

  13. Exercise Relaxation Mode

  14. Release Pressure Mode

  15. Full Body Air Pressure Mode

  16. Upper Body Mode

  17. Lower Body Mode

  18. Quick Massage Mode

  19. 4D Adjust

  20. Speed Adjust

  21. Time

  22. Air Pressure Adjust

  23. Heating

  24. Foot Roller

  25. Calf Roller

2.3 Manual Mode

  1. Massage Area Setting

  2. Massage Manipulation Setting

  3. Upper Mechanism Setting

  4. Lower Mechanism Setting

  5. Massage Area

  6. Massage Manipulation

  7. Upper Mechanism

  8. Lower Mechanism

  9. Massage Manipulation

  10. Massage Area

2.4 Air Bag Massage

  1. Full Body Air Bag
  2. Shoulder Air Bag
  3. Hand Air Bag
  4. Hip Air Bag
  5. Foot Air Bag
  6. Calf Air Bag

2.5. Zero Gravity

  1. Zero Gravity Angle
  2. Best Angle For Watching TV
  3. Best Angle To Read

2.6. Others

  1. Heating
  2. Foot Roller Massage
  3. Calf Roller Massage
  4. Speech

2.7. System Settings

  1. Intensity Control
  2. Volume Adjustment

Shortcut Button Description Osaki OP 4D Solis Massage Chair - Control
9

  1. Full Body Relaxation
  2. Neck& Shoulder Massage
  3. Handstand Stretch
  4. Leg Up
  5. Leg Down

Switch Key And Knob Key
Switch key: Long press this button to turn on/off the massage chair Knob key: Clockwise to Recline; and Anticlockwise to Raise
After Use

  1. Press the On/Off button to disable all functions.
  2. Turn off the power switch (to ”0” ) located at the back of the chair.
  3. Remove plug from power socket.
  • Please do not pull on the power cord to remove the plug.

The voice commands are as follows:
Voice Control entry
Awakening Word:“Hi Osaki.” Answer:“ Hello”

No. Voice Control entry
1 Turn on massage
2 Turn off massage
3 Leisure massage
4 Stretching massage
5 Swing mode
6 Strong massage
7 Sleep massage
8 Neck and shoulders relax
9 Increase intensity
10 Reduce intensity
11 Maximum intensity
12 Minimum intensity
13 Turn on airbag
14 Turn off airbag
15 Increase air pressure
16 Reduce air pressure
17 Turn on Foot Roller
18 Turn off Foot Roller
19 Turn on heat
20 Turn off heat
21 Volume up
22 Volume down
23 Maximum volume
24 Minimum volume
25 Backrest down
26 Backrest up
27 Zero gravity
28 Raise leg
29 Lower leg
30 Pause massage
31 Start massage

The voice mode is automatically activated when power on. If the voice function is disabled, enable it again by choosing on the screen. When the voice function is enabled successfully, please wake up the chair by calling “Hi Osaki” first and you will see the chair responds “Hello”. And the next command you need to call is “Turn on massage” to activate the starting function of chair and you can use other commands then. The chair need to be woken up after every 8 seconds of rest. Please note that Intensity and air pressure adjustment can only be effective when the corresponding function is turned on, otherwise it is invalid. For example, you need to open the air bag massage before you request it to increase air pressure.

Troubleshooting

This page summarizes the most common problems you would encounter with the product.
If you are unable to solve the problem with the information below, please contact its authorized dealers immediately.

Problem Possible Cause Suggestion
The product does not work The product is not plugged in properly. Ensure the

voltage on the product corresponds to the local mains voltage and then plug in again. Then turn on the power switch.
The product has just finished its 15-min auto timer session and has automatically switched to standby mode.| If you want another session, press the ****button again.
You may have used the product continuously for more than 45 minutes and the overheat protection has been activated.| Unplug the product and let it cool down for 60 minutes before you use it again.
An excessive load has been applied on the product.| Reduce the excessive load and start again.
The product is abnormally warm| The product is likely to be overused.| Unplug the product and let it cool down before using it again.
Noise can be heard from the product| Noise is made by the mechanical parts of the product.| This is normal and does not mean that the product is faulty.

Care & Maintenance

Osaki OP 4D Solis Massage Chair - Control 14 Clean
Never use scouring pads,abrasive cleaning agents(e.g.,benzene or thinner),or harsh chemicals such as petroleum or acetone to clean the chair.

  1. Shut off and pull out the plug before cleaning the chair.
  2. Use a dry cloth to clean.
  3. Do not use a wet cloth and chemical cleanser.

Storage

  1. Disconnect the massage chair from the power source after use.
  2. Do not expose the massage chair to direct sunlight,high temperature,or high humidity .This could cause fading or other damage to the upholstery.
  3. Do not put heavy objects on the massage chair.

If the outer cover is torn or the mechanism is damaged,stop using the chair and contact us for assistance.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals