RECPRO RP-1031 Macerator Pump Instruction Manual
- June 1, 2024
- RecPro
Table of Contents
RECPRO RP-1031 Macerator Pump
Installation & Maintenance
- The DC macerator pump can be used in Yacht, RV, and Mobile kitchenware, Toilet exhaust systems.
- It is designed to empty marine and RV holding tanks of normal waste.
- It is also an excellent choice for emptying fish boxes of scales and residual waste.
- A flow rate of up to 12 gallons(45. OLPM)per minute conveniently emptys any tank in minutes.
- The unique dual-cut blade design ensures waste is ground up thoroughly.
- The pump is self-priming up to a five-foot lift when the impeller is wet, and a foot lift when the impeller is dry, but for optimum performance and life, it should be mounted as close to the tank as possible.
- Marine pump-out must be in proper discharge zones only. This macerator will not handle hard objects, rags, or feminine, napkins.
Product Specifications
- Motor: Seamless can motor, Thermally protected.
- Do Not Run Dry Capability Pump Type: Flexible impeller
- Duty Cycle: Intermittent duty only
- Impeller: NBR70°
- Blade: 316 stainless “Double Cut”
- DIMENSION: SEE DRAWING
- WEIGHT: 4.99l(2. 24kg)
- PRESSURE OFF (PSI/BAR): NO
DIMENSION
Electrical Connections
WARNING: If the pump is operated in an area containing flammable vapors, the wire leads must be joined by insulated mechanical locking connectors. Loose or inadequate wire connections can spark, resulting in an explosion and in property damage, injury, or death, all electrical installations should be done by a qualified electrician.
- The pump should be operated on a separate circuit.
- The pump should be connected to the properly sized momentary switch. This prevents the pump from damage due to long periods of dry run conditions.
- The switch should be near the pump. This will allow the operator to hear the change in pump sound when the tank is empty.
FAQs
What is the maximum flow rate of the macerator pump?
The maximum flow rate is up to 12 gallons per minute.
Can the macerator pump be run dry?
No, the macerator pump does not have dry run capability and should not be operated without liquid.
What type of waste can the macerator handle?
The macerator is designed for normal waste and fish box scales and residual waste. It cannot handle hard objects, rags, or feminine products.
Where should the macerator pump be installed?
For optimal performance, the macerator pump should be mounted as close to the tank as possible and used only in proper marine discharge zones.
What precautions should be taken during electrical installations?
All electrical connections should be made with insulated mechanical locking connectors to prevent sparks and should be performed by a qualified electrician.