Mitsubishi Electric TPKA0A.1LA Series Split System Heat Pump Owner’s Manual

June 17, 2024
Mitsubishi Electric

Mitsubishi Electric TPKA0A.1LA Series Split System Heat Pump

Mitsubishi-Electric-TPKA0A.1LA-Series-Split-System-Heat-Pump-
prodduct

Product Information

Specifications

  • Brand: MITSUBISHI ELECTRIC TRANE HVAC US
  • Model: SPLIT-SYSTEM HEAT PUMP TPKA0A.1LA Series
  • Language: English, French, Spanish
  • Parts Names: Indoor Unit, Wired Remote Controller

Product Usage Instructions

Safety Precautions
Before operating the air-conditioner unit, ensure you have read and understood all safety precautions outlined in the manual. These precautions are crucial for ensuring safe use of the product.

Part Names
The product consists of an Indoor Unit and a Wired Remote Controller. The Indoor Unit includes features such as fan speed control, vane adjustment, louvres, filters with cleaning indication, and wireless remote controller model number setting. The Wired Remote Controller has buttons for menu navigation, function selection, and ON/OFF controls.

Operation
Refer to the operation section of the manual for detailed instructions on how to operate the air-conditioner unit effectively. This section covers setting temperature, fan speed, mode selection, and energy-saving features.

Care and Cleaning
Maintaining the cleanliness of the air-conditioner unit is essential for optimal performance. Regularly clean filters, louvers, and air intake areas as per the provided guidelines to ensure efficient operation.

Troubleshooting
If you encounter any issues with the product, refer to the troubleshooting section of the manual for guidance on identifying and resolving common problems. Follow the recommended steps to troubleshoot effectively.

FAQs

  • Q: What should I do when I need to dispose of the unit?
    A: When you need to dispose of the unit, it is recommended to consult your dealer for proper disposal procedures. Ensure safe and environmentally friendly disposal methods are followed.

  • Q: How do I save settings using the Wired Remote Controller?
    A: To save settings on the Wired Remote Controller, press the SELECT/HOLD button after adjusting the desired settings. This will store the settings for future use.

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

Note:

  • The phrase “Wired remote controller” in this operation manual refers only to the TAR-41MAA.
  • If you need any information for the other remote controller, please refer to the instruction book included in box.

Safety Precautions

  • Before installing the unit, make sure you read all the “Safety Precautions”.
  • The “Safety Precautions” provide very important points regarding safety. Make sure you follow them.
  • Please report to or get consent by the supply authority before connection to the system.

Symbols used in the text

  • Warning:
    Describes precautions that should be observed to prevent danger of injury or death to the user.

  • Caution:
    Describes precautions that should be observed to prevent damage to the unit.

Symbols used in the illustrations

  • : Indicates a part that must be grounded.

Warning:

  • Their appliances are not accessible to the general public.
  • The unit must not be installed by the user. Ask the dealer or an authorized company to install the unit. If the unit is installed improperly, water leakage, electric shock or fire may result.
  • Do not alter the unit. It may cause fire, electric shock, injury or water leakage.
  • Do not stand on, or place any items on the unit.
  • Do not splash water over the unit and do not touch the unit with wet hands. An electric shock may result.
  • Do not spray combustible gas close to the unit. Fire may result.
  • Do not place a gas heater or any other open-flame appliance where it will be exposed to the air discharged from the unit. Incomplete combustion may result.
  • Do not remove the front panel or the fan guard from the outdoor unit when it is running.
  • When you notice exceptionally abnormal noise or vibration, stop op-eration, turn off the power switch, and contact your dealer.
  • Never insert fingers, sticks etc. into the intakes or outlets.
  • If you detect odd smells, stop using the unit, turn off the power switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result.
  • This air conditioner is NOT intended for use by children or infirm persons without supervision.
  • If the refrigeration gas blows out or leaks, stop the operation of the air conditioner, thoroughly ventilate the room, and contact your dealer.
  • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
  • Children should be supervised to ensure that they do not play with the air conditioner.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  • When installing relocating, or servicing the air conditioner, use only the specified refrigerant written on the outdoor unit to charge the refrigerant lines. Do not mix it with any other refrigerant and do not allow air to remain in the lines.
    • If air is mixed with the refrigerant, then it can cause abnormally high pressure in the refrigerant line and may result in an explosion and other hazards.
    • The use of any refrigerant other than that specified for the system will cause mechanical failure system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
  • This unit should be installed in rooms that exceed the floor space specified in the outdoor unit installation manual. Refer to the outdoor unit installation manual.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operat-ing ignition sources (for example open flames, an operating gas appli-ance or an operating electric heater).
  • Do not pierce or burn.
  • Be aware that refrigerants may not contain an odour.

Caution:

  • Do not use any sharp object to push the buttons, as this may damage the remote controller.
  • Never block or cover the indoor or outdoor unit’s intakes or outlets.

Disposing of the unit
When you need to dispose of the unit, consult your dealer.

Parts Names

Indoor Unit
  TPKA0A.1LA10A
Fan speed 4 speeds + Auto
Vane Auto with swing
Louver Manual
Filter Normal
Filter cleaning indication 100 hr
Wireless remote controller model No. setting 001
Wired Remote Controller

Controller interface

  • The functions of the function buttons change depending on the screen.
  • Refer to the button function guide that appears at the bottom of the LCD for the functions they serve on a given screen.
  • When the system is centrally controlled, the button function guide that corresponds to the locked button will not appear.

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(3\)

  1. [ON/OFF] button
    Press to turn ON/OFF the indoor unit.

  2. [SELECT/HOLD] button
    Press to save the setting. When the Main menu is displayed, pressing this button will enable/disable the HOLD function.

  3. [RETURN] button
    Press to return to the previous screen.

  4. [MENU] button
    Press to bring up the Main menu.

  5. Backlit LCD
    Operation settings will appear.

    • When the backlight is off, pressing any button turns the backlight on and it will stay lit for a certain time depending on the screen.
    • When the backlight is off , pressing any button turns the backlight on and does not perform its function. (except for the [ON/OFF] button)
  6. ON/OFF lamp
    This lamp lights up in green while the unit is in operation. It blinks while the remote controller is starting up or when there is an error.

  7. Function button [F1]

    • Main display: Press to change the operation mode.
    • Menu screen: The button function varies with the screen.
  8. Function button [F2]

    • Main display: Press to decrease temperature.
    • Main menu: Press to move the cursor left.
    • Menu screen: The button function varies with the screen.
  9. Function button [F3]

    • Main display: Press to increase temperature.
    • Main menu: Press to move the cursor right.
  10. Function button [F4]
    Main display: Press to change the fan speed.

Display

The main display can be displayed in two different modes: “Full” and “Basic”. The factory setting is “Full”. To switch to the “Basic” mode, change the setting on the Main display setting. (Refer to operation manual included with remote controller.)

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(5\)

  1. Operation mode

  2. Preset temperature

  3. Clock

  4. Fan speed

  5. Button function guide
    The functions of the corresponding buttons appear here.

  6. Appears when the ON/OFF operation is centrally controlled.

  7. Appears when the operation mode is centrally controlled.

  8. Appears when the preset temperature is centrally controlled.

  9. Appears when the filter reset function is centrally controlled.

  10. Indicates when the filter needs maintenance.

  11. Room temperature

  12. Appears when the buttons are locked.

  13. Appears when the On/Off timer or Auto-off timer function is enabled.

    • appears when the timer is disabled by the centralized control system.
    • appears when the HOLD function is enabled.
  14. Appears when the Weekly timer is enabled.

  15. Appears while the units are operated in the energy-save mode. (Will not appear on some models of indoor units)

  16. Appears while the outdoor units are operated in silent mode. (This indication is not available for CITY MULTI models)

  17. Appears when the built-in thermistor on the remote controller is activated to monitor the room temperature (1).

    • appears when the thermistor on the indoor unit is activated to monitor the room temperature.
  18. Indicates the vane setting.

  19. Indicates the Louvre setting.

  20. Indicates the ventilation setting.

  21. Appears when the preset temperature range is restricted.

  22. Appears when an energy-saving operation is performed using a “3D i- See sensor” function.

  23. Centrally controlled
    Appears for a certain time when a centrally controlled item is operated.

  24. Preliminary error display
    An error code appears during the preliminary error.

Most settings (except ON/OFF, mode, fan speed, and temperature) can be made from the Main menu.

Outdoor unit

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(25\)

Operation

About the operation method, refer to the operation manual that comes with each remote controller.

Turning ON/OFF

[ON]

  • Press the [ON/OFF] button. The ON/OFF lamp will light up in green, and the operation will start. When “LED lighting” is set to “No,” the ON/OFF lamp will not light up.
  • Refer to the installation manual of wired remote controller.

[OFF]

  • Press the [ON/OFF] button again.
  • The ON/OFF lamp will come off, and the operation will stop.

Note:
Even if you press the ON/OFF button immediately after shutting down the operation is progress, the air conditioner will not start for about 3 minutes. This is to prevent the internal components from being damaged.

Operation status memory

  Remote controller setting
Operation mode Operation mode before the power was turned off
Preset temperature Preset temperature before the power was turned off
Fan speed Fan speed before the power was turned off

Settable preset temperature range

Operation mode Preset temperature range
Cool/Drying 19–30 ºC/67–87 °F
Heat 17–28 ºC/63–83 °F
Auto (single set point) 19–28 ºC/67–83 °F
Setback [COOL] Preset temperature range for COOL mode. [HEAT] Preset

temperature range for HEAT mode. *1
Fan/Ventilation| Not settable

The preset temperatures for cooling and heating can be set under the following conditions.

  • The cooling preset temperature is greater than the heating preset temperature.
  • The difference between the cooling and heating preset temperatures is equal to or greater than the minimum temperature difference that varies depending on the indoor unit model to be connected.

Mode Selection
Each pressing of the [F1] button cycles through the following operation modes. Select the desired operation mode.Mitsubishi-Electric TPKA0A.1LA Series-
Split-System-Heat-Pump-fig- \(28\)

What the blinking mode icon means
The mode icon will blink when other indoor units in the same refrigerant system (connected to the same outdoor unit) are already operated in a different mode. In this case, the rest of the unit in the same group can only be operated in the same mode.

Automatic operation

Single set point

  • According to a set temperature, the cooling operation starts if the room temperature is too hot and the heating operation starts if the room temperature is too cold.
  • During automatic operation, if the room temperature changes and remains 2 °C, 4 °F or more above the set temperature for 15 minutes, the air conditioner switches to cool mode. In the same way, if the room temperature remains 2 °C, 4 °F or more below the set temperature for 15 minutes, the air conditioner switches to heat mode.

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(29\)

Because the room temperature is automatically adjusted to maintain a fixed effective temperature, the cooling operation is performed a few degrees warmer and the heating operation is performed a few degrees cooler than the set room temperature once the temperature is reached (automatic energy-saving operation).

Navigating through the screens

  • To return to the Main screen …… [RETURN] button

Temperature setting
<Cool, Drying, Heat, and Auto>

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(30\)

Fan speed setting

Press the [F4] button to go through the fan speeds in the following order.

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(32\)

  • The available fan speeds depend on the models of connected indoor
    units.

Notes:

  • The number of available fan speeds depends on the type of unit connected.
  • In the following cases, the actual fan speed generated by the unit will diff er from the speed shown the remote controller display.
    1. While the display is in “Standby” or “Defrost” states.
    2. When the temperature of the heat exchanger is low in the heating mode. (e.g. immediately after heating operation starts)
    3. In HEAT mode, when room temperature is higher than the temperature setting.
    4. In COOL mode, when room temperature is lower than the temperature setting.
    5. When the unit is in Drying mode.

Airfl ow direction setting

Navigating through the Main menu

  • Press the [MENU] button on the Main display.
  • The Main menu will appear.

Item selection

  • Press [F2] to move the cursor left.
  • Press [F3] to move the cursor right.

Exiting the Main menu screen
Press the [RETURN] button to exit the Main menu and return to the Main display.

If no buttons are touched for 10 minutes, the screen will automatically return to the Main display. Any settings that have not been saved will be lost.

Display of unsupported functions
The message at left will appear if the user selects a function not supported by the corresponding indoor unit model.

Vane·Vent. (Lossnay)

Accessing the menu

  • Select “Operation” from the Main menu (refer to 3.5.1), and press the [SELECT/HOLD] button.
  • Select “Vane·Louver·Vent. (Lossnay)” from the Operation menu, and press the [SELECT/HOLD] button.

Vane setting

  • Press the [F1] or [F2] button.
  • Press the button as indicated above to go through the following setting options.
  • Select “Swing” to move the vanes up and down automatically. When set to “Step 1” through “Step 5”, the vane will be fixed at the selected angle.
  • 1h under the vane setting icon
    • This icon will appear when the vane is set to “Step 5” and the fan operates at low speed during cooling or drying operation (depending on the model).
    • The icon will go off in an hour, and the vane setting will automatically change.

Vent. setting

  • Press the [F4] button to go through the ventilation setting options in the order of “Off”, “Low”, and “High”.
    • Settable only when the LOSSNAY unit is connected.
  • The fan on some models of indoor units may be interlocked with certain models of ventilation units.

Returning to the Main menu
Press the [RETURN] button to go back to the Main menu.

Note:

  • During swing operation, the directional indication on the screen does not change in sync with the directional vanes on the unit.
  • Available directions depend on the type of unit connected.
  • In the following cases, the actual air direction will differ from the direction indicated on the remote controller display.
    1. While the display is in “Standby” or “Defrost” states.
    2. Immediately after starting heat mode (while the system is waiting for the mode change to take effect).
    3. In heat mode, when the room temperature is higher than the temperature setting.

[Manual] To Change the Airflow’s Left/Right Direction

  • The louver button cannot be used.
  • Stop the unit operation, hold the lever of the louver, and adjust to the desired direction.
  • Do not set to the inside direction when the unit is in the cooling or drying mode because there is a risk of condensation and water dripping.

Caution:
To prevent falls, maintain a stable footing when operating the unit.

Ventilation

For LOSSNAY combination

  • The following 2 patterns of operation are available.
    • Run the ventilator together with the indoor unit.
    • Run the ventilator independently.

For wireless remote controller

  • Running the ventilator independently is not available.
  • No indication on the remote controller.

Emergency Operation for Wireless Remote-controller

When the remote controller cannot be used
When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the emergency buttons on the grille.

  • A STANDBY lamp
  • B OPERATING lamp
  • C Emergency operation cooling switch
  • D Emergency operation heating switch
  • E ReceiverMitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig- \(45\)

Starting operation

  • To operate the cooling mode, press the button C for more than 2 seconds.
  • To operate the heating mode, press the button D for more than 2 seconds.
  • Lighting of the OPERATING lamp B means the start of operation.

Operation Monitor Display

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(47\)

Operation details at the time of emergency operation are as shown below. Note that over the first 30 minutes or so, the temperature adjustment will not function and the unit will be in continuous operation with the fan on high.

Operation Mode COOL HEAT
Set Temperature 24°C, 75°F 24°C, 75°F
Fan Speed High High
Airflow Direction Up and Down Step 1 Step 5

Care and Cleaning

Filter information
will appear on the Main display in the Full mode when it is time to clean the filters.

  • Wash, clean, or replace the filters when this sign appears.

  • Refer to the indoor unit Instructions Manual for details.

  • Select “Maintenance” from the Main menu, and press the [SELECT/HOLD] button.

  • Select “Filter information” from the Maintenance menu, and press the [SELECT/HOLD] button.

  • Press the [F4] button to reset filter sign.

  • Refer to the indoor unit Instructions Manual for how to clean the filter.

  • Select “OK” with the [F4] button.

  • A confirmation screen will appear.
    Navigating through the screens

    • To go back to the Main menu ………………….. [MENU] button
    • To return to the previous screen ………………….. [RETURN] button
  • When the is displayed on the Main display in Full mode, the system is centrally controlled and the filter sign cannot be reset.

  • If two or more indoor units are connected, filter cleaning timing for each unit may be different, depending on the filter type.

  • The icon will appear when the filter on the main unit is due for cleaning.

  • When the filter sign is reset, the cumulative operation time of all units will be reset.

  • The icon is scheduled to appear after a certain duration of operation, based on the premise that the indoor units are installed in a space with ordinary air quality. Depending on the air quality, the filter may require more frequent cleaning.

  • The cumulative time at which filter needs cleaning depends on the model.

    • This indication is not available for wireless remote controller.

Caution:
Ask authorized people to clean the filter.

Cleaning the filters

  • Clean the filters using a vacuum cleaner. If you do not have a vacuum cleaner, tap the filters against a solid object to knock off dirt and dust.
  • If the filters are especially dirty, wash them in lukewarm water. Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit.
  1. Pull both the bottom corners of the grille to open the grille, then lift the filter.
    • A. Filter
    • B. Grille

Caution:

  • Do not dry the filters in direct sunlight or by using a heat source, such as an electric heater: this may warp them.
  • Do not wash the filters in hot water (above 50 °C, 122 °F), as this may warp them.
  • Make sure that the air filters are always installed. Operating the unit without air filters can cause malfunction.
  • Before you start cleaning, stop the operation and turn OFF the power supply.
  • Indoor units are equipped with filters to remove the dust of sucked-in air. Clean the filters using the methods shown in the sketches above.

Cleaning the indoor unit

Mitsubishi-Electric TPKA0A.1LA Series-Split-System-Heat-Pump-fig-
\(55\)

  • Wipe the outside of the unit with a clean, dry, soft cloth.
  • Clean off any oil stains or finger marks using a neutral household detergent (such as dishwashing liquid or laundry detergent).

Caution:
Never use gasoline, benzene, thinner, scouring powder or any type of non- neutral detergent, as these substances may damage the unit’s case.

Trouble Shooting

Having trouble?

|

Here is the solution. (Unit is operating normally.)

---|---
The air conditioner does not heat or cool well.| ■ Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)

■ Check the temperature adjustment and adjust the set temperature.

■ Make sure that there is plenty of space around the outdoor unit. Is the indoor unit air intake or outlet blocked?

■ Has a door or window been left open?

When the heating operation starts, warm air does not blow from the indoor unit soon.| ■ Warm air does not blow until the indoor unit has sufficiently warmed

up.

During heating mode, the air conditioner stops before the set room temperature is reached.| ■ When the outdoor temperature is low and the humidity is high, frost

may form on the outdoor unit. If this occurs, the outdoor unit performs a defrosting operation. Normal operation should begin after approximately 10 minutes.

Airflow direction changes during operation or airflow direction cannot be

set.

| ■ During cooling mode, the vanes automatically move to the horizontal

(down) position after 1 hour when the down (horizontal) airflow direction is selected. This is to prevent water from forming and dripping from the vanes.

■ During the heating mode, the vanes automatically move to the horizontal

airflow direction when the airflow temperature is low or during the defrosting mode.

When the airflow direction is changed, the vanes always move up and down past the set position before finally stopping at the position.| ■ When the airflow direction is changed, the vanes move to the set position after detecting the base position.
A flowing water sound or occasional hissing sound is heard.| ■ These sounds can be heard when the refrigerant is flowing in the air conditioner or when the refrigerant flow is changing.
A cracking or creaking sound is heard.| ■ These sounds can be heard when parts rub against each other due to expansion and contraction from temperature changes.
The room has an unpleasant odour.| ■ The indoor unit draws in air that contains gases produced from the walls, carpeting, and furniture as well as odours trapped in clothing, and then blows this air back into the room.
A white mist or vapor is emitted from the indoor unit.| ■ If the indoor temperature and the humidity are high, this condition may

occur when the operation starts.

■ During defrosting mode, cool airflow may blow down and appear like a

mist.

Water or vapor is emitted from the outdoor unit.| ■ During cooling mode, water may form and drip from the cool pipes and

joints.

■ During heating mode, water may form and drip from the heat exchanger.

■ During defrosting mode, water on the heat exchanger evaporates and

water vapour may be emitted.

“  ” appears in the remote controller display.| ■ During central control, “  ” appears in the remote controller display

and air conditioner operation cannot be started or stopped using the remote controller.

When restarting the air conditioner soon after stopping it, it does not operate even though the ON/OFF button is pressed.| ■ Wait approximately 3 minutes. (Operation has stopped to protect the

air conditioner.)

Air conditioner operates without the ON/OFF button being pressed.| ■ Is the on-timer set?

Press the ON/OFF button to stop the operation.

■ Is the air conditioner connected to a central remote controller?

Consult the concerned people who control the air conditioner.

■ Does “  ” appear in the remote controller display?

Consult the concerned people who control the air conditioner.

■ Has the auto-recovery feature from power failures been set?

Press the ON/OFF button to stop the operation.

Air conditioner stops without the ON/OFF button being pressed.| ■ Is the off- timer set?

Press the ON/OFF button to restart the operation.

■ Is the air conditioner connected to a central remote controller?

Consult the concerned people who control the air conditioner.

■ Does “  ” appear in the remote controller display?

Consult the concerned people who control the air conditioner.

Remote controller timer operation cannot be set.| ■ Are timer settings invalid?

If the timer can be set or appears in the remote controller display.

“Please Wait” appears in the remote controller display.| ■ The initial settings are being performed. Wait approximately 3 minutes.
An error code appears in the remote controller display.| ■ The protection devices have operated to protect the air conditioner.

■ Do not attempt to repair this equipment by yourself.

Turn off the power switch immediately and consult your dealer. Be sure to provide the dealer with the model name and information that appeared in the remote controller display.

Having trouble?

|

Here is the solution. (Unit is operating normally.)

---|---
Draining water or motor rotation sound is heard.| ■ When the cooling operation stops, the drain pump operates and then stops.

Wait approximately 3 minutes.

Noise is louder than specifications.| ■ The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in an anechoic room.
Nothing appears in the wireless remote controller display, the display is faint, or signals are not received by the indoor unit unless the remote controller is closed.| ■ The batteries are low.

Replace the batteries and press the Reset button.

■ If nothing appears even after the batteries are replaced, make sure

that the batteries are installed in the correct directions (+, –).

After battery installation/replacement of the remote controller, part of the function cannot be used.| ■ Please check that the clock setting is completed. If the clock setting is not done, please complete it.
The operation lamp near the receiver for the wireless remote controller on the indoor unit is blinking.| ■ The self-diagnosis function has operated to protect the air conditioner.

■ Do not attempt to repair this equipment by yourself.

Turn off the power switch immediately and consult your dealer. Be sure to provide the dealer with the model name.

The indoor unit which is not operating becomes warm and a sound, similar to water flowing, is heard from the unit.| ■ A small amount of refrigerant continues to flow into the indoor unit even though it is not operating.

Specifications

Model TPKA0A0121LA10A TPKA0A0181LA10A
Power source (Voltage/Frequency) <V/Hz> Single, 208/230 V, 60 Hz
Rated Capacity (Cooling/Heating) <BTU/h> 12,000/14,000
Rated Input (Cooling/Heating indoor only) 0.06/0.03
Rated Current (Cooling/Heating indoor only) 0.55/0.30
Dimension (Height) <mm (inch)> 299 (11-25/32)
Dimension (Width) <mm (inch)> 898 (35-23/64)
Dimension (Depth) <mm (inch)> 237 (9-11/32)
Net weight <kg (lbs)> 12.7 (28.0)

Fan Airflow rate

(Low-Middle2-Middle1-High)

| DRY | 265 – 290 – 325 – 385| 265 – 310 – 375 – 450
WET | 215 – 255 – 320 – 375| 215 – 255 – 320 – 375
Noise level

(Low-Middle2-Middle1-High)

| DRY | 34 – 37 – 40 – 43| 34 – 39 – 44 – 48
WET | 34 – 39 – 44 – 48| 34 – 39 – 44 – 48

Software Information

This product includes open-source software (“OSS”) distributed under the terms of open-source licenses.

Apache License
Version 2.0, January 2004 http://www.apache.org/licenses/.

TERMS AND CONDITIONS FOR USE, REPRODUCTION, AND DISTRIBUTION

  1. Definitions.
    • “License” shall mean the terms and conditions for use, reproduction, and distribution as defined by Sections 1 through 9 of this document.
    • “Licensor” shall mean the copyright owner or entity authorized by the copyright owner that is granting the License.
    • “Legal Entity” shall mean the union of the acting entity and all other entities that control, are controlled by, or are under common control with that entity. For this definition, “control” means (i) the power, direct or indirect, to cause the direction or management of such entity, whether by contract or otherwise, or (ii) ownership of fifty per cent (50%) or more of the outstanding shares, or (iii) beneficial ownership of such entity.
    • “You” (or “Your”) shall mean an individual or Legal Entity exercising permissions granted by this License.
    • “Source” form shall mean the preferred form for making modifications, including but not limited to software source code, documentation source, and configuration files.
    • “Object” form shall mean any form resulting from mechanical transformation or translation of a Source form, including but not limited to compiled object code, generated documentation, and conversions to other media types.
    • “Work” shall mean the work of authorship, whether in Source or Object form, made available under the License, as indicated by a copyright notice that is included in or attached to the work (an example is provided in the Appendix below).
    • “Derivative Works” shall mean any work, whether in Source or Object form, that is based on (or derived from) the Work and for which the editorial revisions, annotations, elaborations, or other modifications represent, as a whole, an original work of authorship. For this License, Derivative Works shall not include works that remain separable from, or merely link (or bind by name) to the interfaces of, the Work and Derivative Works thereof.
    • “Contribution” shall mean any work of authorship, including the original version of the Work and any modifications or additions to that Work or Derivative Works thereof, that is intentionally submitted to Licensor for inclusion in the Work by the copyright owner or by an individual or Legal Entity authorized to submit on behalf of the copyright owner. For this definition, “submitted” means any form of electronic, verbal, or written communication sent to the Licensor or its representatives, including but not limited to communication on electronic mailing lists, source code control systems, and issue tracking systems that are managed by, or on behalf of, the Licensor to discuss and improve the Work, but excluding communication that is conspicuously marked or otherwise designated in writing by the copyright owner as “Not a Contribution.”
    • “Contributor” shall mean the Licensor and any individual or Legal Entity on behalf of whom a Contribution has been received by the Licensor and subsequently incorporated within the Work.
  2. Grant of Copyright License. Subject to the terms and conditions of this License, each Contributor hereby grants to You a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare Derivative Works of, publicly display, publicly perform, sublicense, and distribute the Work and such Derivative Works in Source or Object form.
  3. Grant of Patent License. Subject to the terms and conditions of this License, each Contributor hereby grants to You a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable (except as stated in this section) patent license to make, have made, use, offer to sell, sell, import, and otherwise transfer the Work, where such license applies only to those patent claims licensable by such Contributor that are necessarily infringed by their Contribution(s) alone or by combination of their Contribution(s) with the Work to which such Contribution(s) was submitted. If You institute patent litigation against any entity (including a cross-claim or counterclaim in a lawsuit) alleging that the Work or a Contribution incorporated within the Work constitutes direct or contributory patent infringement, then any patent licenses granted to You under this License for that Work shall terminate as of the date such litigation is filed.
  4. Redistribution. You may reproduce and distribute copies of the Work or Derivative Works thereof in any medium, with or without modifications, and in Source or Object form, provided that You meet the following conditions:
    • You must give any other recipients of the Work or Derivative Works a copy of this License; and
    • You must cause any modified files to carry prominent notices stating that You changed the files; and
    • You must retain, in the Source form of any Derivative Works that You distribute, all copyright, patent, trademark, and attribution notices from the Source form of the Work, excluding those notices that do not pertain to any part of the Derivative Works; and
    • If the Work includes a “NOTICE” text file as part of its distribution, then any Derivative Works that You distribute must include a readable copy of the attribution notices contained within such NOTICE file, excluding those notices that do not pertain to any part of the Derivative Works, in at least one of the following places: within a NOTICE text file distributed as part of the Derivative Works; within the Source form or documentation, if provided along with the Derivative Works; or, within a display generated by the Derivative Works, if and wherever such third-party notices normally appear. The contents of the NOTICE file are for informational purposes only and do not modify the License. You may add Your attribution notices within Derivative Works that You distribute, alongside or as an addendum to the NOTICE text from the Work, provided that such additional attribution notices cannot be construed as modifying the License.
    • You may add Your own copyright statement to Your modifications and may provide additional or different license terms and conditions for the use, reproduction, or distribution of Your modifications, or for any such Derivative Works as a whole, provided Your use, reproduction, and distribution of the Work otherwise complies with the conditions stated in this License.
  5. Submission of Contributions. Unless You explicitly state otherwise, any Contribution intentionally submitted for inclusion in the Work by You to the Licensor shall be under the terms and conditions of this License, without any additional terms or conditions. Notwithstanding the above, nothing herein shall supersede or modify the terms of any separate license agreement you may have executed with the Licensor regarding such Contributions.
  6. Trademarks. This License does not grant permission to use the trade names, trademarks, service marks, or product names of the Licensor, except as required for reasonable and customary use in describing the origin of the Work and reproducing the content of the NOTICE file.
  7. Disclaimer of Warranty. Unless required by applicable law or agreed to in writing, Licensor provides the Work (and each Contributor provides its Contributions) on an “AS IS” BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied, including, without limitation, any warranties or conditions of TITLE, NON-INFRINGEMENT, MERCHANTABILITY, or FITNESS FOR A PARTICULAR PURPOSE. You are solely responsible for determining the appropriateness of using or redistributing the Work and assume any risks associated with Your exercise of permissions under this License.
  8. Limitation of Liability. In no event and under no legal theory, whether in tort (including negligence), contract, or otherwise, unless required by applicable law (such as deliberate and grossly negligent acts) or agreed to in writing, shall any Contributor be liable to You for damages, including any direct, indirect, special, incidental, or consequential damages of any character arising as a result of this License or out of the use or inability to use the Work (including but not limited to damages for loss of goodwill, work stoppage, computer failure or malfunction, or any other commercial damages or losses), even if such Contributor has been advised of the possibility of such damages.
  9. Accepting Warranty or Additional Liability. While redistributing the Work or Derivative Works thereof, You may choose to offer, and charge a fee for, acceptance of support, warranty, indemnity, or other liability obligations and/or rights consistent with this License. However, in accepting such obligations, You may act only on Your behalf and on Your sole responsibility, not on behalf of any other Contributor, and only if You agree to indemnify, defend, and hold each Contributor harmless for any liability incurred by, or claims asserted against, such Contributor because you accepted any such warranty or additional liability.

APPENDIX: How to apply the Apache License to your work.
To apply the Apache License to your work, attach the following boilerplate notice, with the fields enclosed by brackets “{}” replaced with your own identifying information. (Don’t include the brackets!) The text should be enclosed in the appropriate comment syntax for the file format. We also recommend that a file or class name and description of purpose be included on the same “printed page” as the copyright notice for easier identification within third-party archives.

Copyright {yyyy} {name of copyright owner}
Licensed under the Apache License, Version 2.0 (the “License”); you may not use this file except in compliance with the License. You may obtain a copy of the License at http://www.apache.org/licenses/LICENSE-2.0.

  • Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an “AS IS” BASIS, WITHOUT WARRANTIES OR CONDI-TIONS OF ANY KIND, either express or implied.
  • See the License for the specific language governing permissions and limitations under the License.

This product is designed and intended for use in the residential, commercial and light-industrial environments.

Warranty

For the residents of the USA

U.S. Product Warranty and Registration Information

  • Congratulations on the purchase of your new Mitsubishi Electric Trane HVAC US Cooling & Heating system and thank you for trusting us with your comfort.
  • Your installing contractor may have registered your products on your behalf. To check the registration status or to complete your product registration, please visit us at http://www.metahvac.com/.
  • Be sure to have the model and serial number for each of your indoor and outdoor units ready before starting the registration process.
  • If you need assistance registering your products, call or write to us at:

Mitsubishi Electric Trane HVAC US LLC

  • ATTN: Customer Care Center 1340 Satellite Boulevard Suwanee, GA 30024
  • Phone: 1.800.433.4822
  • E-mail: CustomerCare@hvac.mea.com.

For the residents of Canada

Mitsubishi Electric HVAC Warranty Registration (Canada)
Congratulations on the purchase of your new Mitsubishi Electric heat pump or air conditioning system. To benefit from our extended warranty, your installing contractor must register your system’s products on our website on your behalf within 90 days of installation. The extended warranty covers the system’s parts and compressor for an extended period from the date of installation. Product models and serial numbers are required for online registration.

To register, please ask your installing contractor to visit the warranty registration page at www.mitsubishielectricmeq.ca, complete the registration and provide you with confirmation of registration.

PLEASE NOTE:
Regular maintenance as specified in the owner’s manual is essential to your system performing according to manufacturer specifications over the applicable warranty period. Please review the terms of the product warranty at mitsubishielectric.ca

If you require assistance, please contact info@mitsubishielectric.ca.

Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

MITSUBISHI ELECTRIC TRANE HVAC US LLC
HEAD OFFICE: 1340 SATELLITE BOULEVARD, SUWANEE, GA 30024, USA.

Printed in Thailand.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mitsubishi Electric User Manuals

Related Manuals