MITSUBISHI ELECTRIC PCA-M·KA Series Air Conditioners Instruction Manual
- May 15, 2024
- Mitsubishi Electric
Table of Contents
MITSUBISHI ELECTRIC PCA-M·KA Series Air Conditioners
Product Usage Instructions
Safety Precautions:
Before installing the unit, make sure you read all the Safety Precautions.
The Safety Precautions provide very important points regarding safety. Make
sure you follow them. Please report to or take consent by the supply authority
before connection to the system.
Parts Names:
Refer to the user manual for a detailed list of parts names and their
functions.
Operation:
Follow the steps outlined in the user manual to operate the air conditioner
effectively. Make sure to set the desired temperature and fan speed for
optimal comfort.
Timer:
Use the timer function to schedule when the air conditioner turns on or off.
This can help save energy and ensure the room is at a comfortable temperature
when needed.
Care and Cleaning:
Regularly clean the air filters and ensure the unit is free from any
obstructions for efficient operation. Refer to the user manual for detailed
cleaning instructions.
Trouble Shooting:
If you encounter any issues with the air conditioner, refer to the Trouble
Shooting section of the user manual for common problems and solutions. If
problems persist, contact customer support.
FAQ:
-
Q: What should I do if the air conditioner is not cooling properly?
A: Check if the air filters are clean and there are no obstructions blocking the airflow. Ensure all windows and doors are closed properly for efficient cooling. -
Q: How often should I clean the air filters?
A: It is recommended to clean the air filters every 2 weeks to maintain optimal performance of the air conditioner.
Go to the above website to download manuals, select model name, then choose language. http://www.mitsubishielectric.com/ldg/ibim/
Safety Precautions
This symbol mark is for EU countries only.
This symbol mark is according to the directive 2012/19/EU Article 14
Information for users and Annex IX, and/or to the directive
2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI
ELECTRIC product is designed and manufactured with high quality materials and
components which can be recycled and/or reused. This symbol means that
electrical and electronic equipment, batteries and accumulators, at their end-
of-life, should be disposed of separately from your household waste. If a
chemical symbol is printed beneath the symbol (Fig. 1), this chemical symbol
means that the battery or accumulator contains a heavy metal at a certain
concentration. This will be indicated as follows: Hg: mercury (0.0005%), Cd:
cadmium (0.002%), Pb: lead (0.004%) In the European Union there are separate
collection systems for used electrical and electronic products, batteries and
accumulators. Please, dispose of this equipment, batteries and accumulators
correctly at your local community waste collection/recycling centre. Please,
help us to conserve the environment we live in!
Note: The phrase “Wired remote controller“ in this operation manual refers only to the PAR-41MAA. If you need any information for other remote controller, please refer to the operation manual that is included with the optional remote controller.
Before installing the unit, make sure you read all the “Safety Precautions”.
- The “Safety Precautions” provide very important points regarding safety. Make sure you follow them.
- Please report to or take consent by the supply authority before connection to the system.
MEANINGS OF SYMBOLS DISPLAYED ON INDOOR UNIT AND/OR OUTDOOR UNIT
Symbols used in the text
-
Warning:
Describes precautions that should be observed to prevent danger of injury or death to the user. -
Caution:
Describes precautions that should be observed to prevent damage to the unit.
Symbols used in the illustrations
- : Indicates a part which must be grounded.
Warning:
- There appliances are not accessible to the general public.
- The unit must not be installed by the user. Ask the dealer or an authorized company to install the unit. If the unit is installed improperly, water leakage, electric shock or fire may result.
- Do not alter the unit. It may cause fire, electric shock, injury or water leakage.
- The unit must be securely installed on a structure that can sustain its weight.
- Do not stand on, or place any items on the unit.
- Do not splash water over the unit and do not touch the unit with wet hands. An electric shock may result.
- Do not spray combustible gas close to the unit. Fire may result.
- Do not place a gas heater or any other open-flame appliance where it will be exposed to the air discharged from the unit. Incomplete combustion may result.
- Do not remove the front panel or the fan guard from the outdoor unit when it is running.
- When you notice exceptionally abnormal noise or vibration, stop operation, turn off the power switch, and contact your dealer.
- Never insert fingers, sticks etc. into the intakes or outlets.
- If you detect odd smells, stop using the unit, turn off the power switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result.
- This air conditioner is NOT intended for use by children or infirm persons without supervision.
- Young children must be supervised to ensure that they do not play with the air conditioner.
- If the refrigeration gas blows out or leaks, stop the operation of the air conditioner, thoroughly ventilate the room, and contact your dealer.
- This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- Children should be supervised to ensure that they do not play with the air conditioner.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- When installing or relocating, or servicing the air conditioner, use only the specified refrigerant written on outdoor unit to charge the refrigerant lines. Do not mix it with any other refrigerant and do not allow air to remain in the lines.
- If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant line, and may result in an explosion and other hazards.
- The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
Warning:
- This unit should be installed in rooms which exceed the floor space specified in outdoor unit installation manual. Refer to outdoor unit installation manual.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odour.
Caution:
- Do not use any sharp object to push the buttons, as this may damage the remote controller.
- Never block or cover the indoor or outdoor unit’s intakes or outlets.
- Never wipe the remote controller with benzene, thinner chemical rags, etc.
- Do not operate the unit for a long time in high humidity, e.g. leaving a door or window open. In the cooling mode, if the unit is operated in a room with high humidity (80% RH or more) for a long time, water condensed in the air conditioner may drop and wet or damage furniture, etc.
- Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1.
- Be sure to wrap insulation around the piping. Direct contact with the bare piping may result in burns or frostbite.
- Never put batteries in your mouth for any reason to avoid accidental ingestion.
- Battery ingestion may cause choking and/or poisoning.
- Install the unit on a rigid structure to prevent excessive operation sound or vibration.
- Noise measurement is carried out in accordance with JIS C9612, JIS B8616, ISO 5151(T1), and ISO 13523(T1).
- Do not touch the air outlet vane during operation. Otherwise, condensation may form and the unit may stop operating.
Disposing of the unit
When you need to dispose of the unit, consult your dealer.
Parts Names
Indoor Unit
PCA-M·KA Series | |
---|---|
Fan speed | 4 speeds + Auto |
Vane | Auto with swing |
Louver | Manual |
Filter | Long – life |
Filter cleaning indication | 2500 hr |
PCA-M·KA Series
Wired Remote Controller
Controller interface:
The functions of the function buttons change depending on the screen. Refer
to the button function guide that appears at the bottom of the LCD for the
functions they serve on a given screen. When the system is centrally
controlled, the button function guide that corresponds to the locked button
will not appear.
-
[ON/OFF] button
Press to turn ON/OFF the indoor unit. -
[SELECT] button
Press to save the setting. -
[RETURN] button
Press to return to the previous screen. -
[MENU] button
Press to bring up the Main menu. -
Backlit LCD
Operation settings will appear.
When the backlight is off, pressing any button turns the backlight on and it will stay lit for a certain period of time depending on the screen. When the backlight is off, pressing any button turns the backlight on and does not perform its function. (except for the [ON/OFF] button) -
ON/OFF lamp
This lamp lights up in green while the unit is in operation. It blinks while the remote controller is starting up or when there is an error. -
Function button [F1]
- Main display: Press to change the operation mode.
- Menu screen: The button function varies with the screen.
-
Function button [F2]
- Main display: Press to decrease temperature.
- Main menu: Press to move the cursor left.
- Menu screen: The button function varies with the screen.
-
Function button [F3]
- Main display: Press to increase temperature.
- Main menu: Press to move the cursor right.
- Menu screen: The button function varies with the screen.
-
Function button [F4]
- Main display: Press to change the fan speed.
- Menu screen: The button function varies with the screen.
Display
The main display can be displayed in two different modes: “Full” and
“Basic”. The factory setting is “Full”. To switch to the “Basic” mode, change
the setting on the Main display setting. (Refer to operation manual included
with remote controller.)
Outdoor unit
Operation
About the operation method, refer to the operation manual that comes with each remote controller.
Turning ON/OFF
-
[ON]
Press the [ON/OFF] button. The ON/OFF lamp will light up in green, and the operation will start. When “LED lighting” is set to “No,” the ON/OFF lamp will not light up.- Refer to the installation manual of wired remote controller.
-
[OFF]
Press the [ON/OFF] button again. The ON/OFF lamp will come off, and the operation will stop.
Note:
Even if you press the ON/OFF button immediately after shutting down the
operation is progress, the air conditioner will not start for about 3 minutes.
This is to prevent the internal components from being damaged.
Operation status memory
Remote controller setting | |
---|---|
Operation mode | Operation mode before the power was turned off |
Preset temperature | Preset temperature before the power was turned off |
Fan speed | Fan speed before the power was turned off |
Settable preset temperature range
Operation mode | Preset temperature range |
---|---|
Default | 14 °C Cooling 1, 2 |
Cool/Dry | 19 – 30 °C |
Heat | 17 – 28 °C |
Auto | 19 – 28 °C |
Fan/Ventilation | Not settable |
- It is available when the indoor unit is connected to any of the particular outdoor units.
- Function setting needs to be changed. Refer to the installation manual for the setting method.
Mode Selection
Press the [F1] button to go through the operation modes in the order of
“Cool”, “Dry”, “Fan”, “Auto”, and “Heat”. Select the desiredoperation mode
.
-
What the blinking mode icon means
The mode icon will blink when other indoor units in the same refrigerant system (connected to the same outdoor unit) are already operated in a different mode. In this case, the rest of the unit in the same group can only be operated in the same mode. -
Automatic operation
-
According to a set temperature, cooling operation starts if the room temperature is too hot and heating operation starts if the room temperature is too cold.
-
During automatic operation, if the room temperature changes and remains 2.0 °C or more above the set temperature for 15 minutes, the air conditioner switches to cool mode. In the same way, if the room temperature remains 2.0 °C or more below the set temperature for 15 minutes, the air conditioner switches to heat mode.
-
< Dual set point>
Note: -
This function cannot be set depending on the outdoor unit to be connected. When the operation mode is set to the Auto (dual set point) mode, two preset temperatures (one each for cooling and heating) can be set. Depending on the room temperature, indoor unit will automatically operate in either the Cool or Heat mode and keep the room temperature within the preset range. For details on how to operate, refer to manual of remote controller.
-
Information for multi system air conditioner (Outdoor unit: MXZ series)
-
Multi system air conditioner (Outdoor unit: MXZ series) can connect two or more indoor units with one outdoor unit. According to the capacity, 2 or more units can operate simultaneously.
- When you try to operate 2 or more indoor units with 1 outdoor unit simultaneously, one for the cooling and the other for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor units that will start the operation later cannot operate, indicating an operation state in blinking. In this case, please set all the indoor units to the same operation mode.
- There might be a case that the indoor unit, which is operating in “Auto” mode. Cannot change over to the operating mode “Cool”/“Heat” and becomes a state of standby.
- When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes (max. about 15 minutes) to blow out the warm air.
- In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant flowing may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.
-
Temperature setting
-
< Cool, Dry, and Heat>
Press the [F2] button to decrease the preset temperature, and press the [F3] button to increase.- Refer to the table on page 6 for the settable temperature range for different operation modes.
- Preset temperature range cannot be set for Fan/Ventilation operation.
- Preset temperature will be displayed either in Centigrade in 1-degree increments, or in Fahrenheit, depending on the indoor unit model and the display mode setting on the remote controller.
- Refer to “Function settings” in the installation manual for the 14°C cooling setting.
Fan speed setting
Press the [F4] button to go through the fan speeds in the following order.
- The available fan speeds depend on the models of connected indoor units.
Note: In the following cases, the actual fan speed generated by the unit will differ from the speed shown the remote controller display.
- While the display is showing “Standby” or “Defrost”.
- When the temperature of the heat exchanger is low in the heat mode. (e.g. immediately after heat operation starts)
- In HEAT mode, when room temperature is higher than the temperature setting.
- In COOL mode, when room temperature is lower than the temperature setting.
- When the unit is in DRY mode.
Airflow direction setting
- Navigating through the Main menu
- Vane·Vent. (Lossnay)
Note:
- During swing operation, the directional indication on the screen does not change in sync with the directional vanes on the unit.
- Available directions depend on the type of unit connected.
- In the following cases, the actual air direction will differ from the direction indicated on the remote controller display.
- While the display is in “Standby” or “Defrost” states.
- Immediately after starting heat mode (while the system is waiting for the mode change to take effect).
- In heat mode, when room temperature is higher than the temperature setting.
<[Manual] To Change the Airflow’s Left/Right Direction>
- The louver button cannot be used.
Caution: To prevent falls, maintain a stable footing when operating the unit.
Ventilation
For LOSSNAY combination
- The following 2 patterns of operation is available.
- Run the ventilator together with indoor unit.
- Run the ventilator independently.
Note: (for wireless remote controller)
- Running the ventilator independently is not available.
- No indication on the remote controller.
Timer
For Wired Remote-controller
- Timer functions are different by each remote controller.
- For details on how to operate the remote controller, refer to the appropriate operation manual included with each remote controller.
Care and Cleaning
Filter information
If two or more indoor units are connected, filter cleaning timing for each
unit may be different, depending on the filter type. The icon will appear when
the filter on the main unit is due for cleaning. When the filter sign is
reset, the cumulative operation time of all units will be reset. The icon is
scheduled to appear after a certain duration of operation, based on the
premise that the indoor units are installed in a space with ordinary air
quality. Depending on the air quality, the filter may require more frequent
cleaning.
The cumulative time at which filter needs cleaning depends on the model.
- This indication is not available for wireless remote controller.
Cleaning the filters
- Clean the filters using a vacuum cleaner. If you do not have a vacuum cleaner, tap the filters against a solid object to knock off dirt and dust.
- If the filters are especially dirty, wash them in lukewarm water. Take care to rinse off any detergent thoroughly and allow the filters to dry completely before putting them back into the unit.
Caution:
- Do not dry the filters in direct sunlight or by using a heat source, such as an electric heater: this may warp them.
- Do not wash the filters in hot water (above 50°C), as this may warp them.
- Make sure that the air filters are always installed. Operating the unit without air filters can cause malfunction.
Caution:
- Before you start cleaning, stop operation and turn OFF the power supply.
- Indoor units are equipped with filters to remove the dust of suckedin air. Clean the filters using the methods shown in the following sketches.
PCA-M·KA
- Open the intake grille.
- Hold the knob on the filter then pull the filter up in the direction of an arrow. To replace the filter after cleaning, be sure to insert the filter far enough until it fits into the stopper.
- A. Filter
- B. Intake Grille
- C. Knob
- D. Stopper
Trouble Shooting
Having trouble? | Here is the solution. (Unit is operating normally.) |
---|---|
Air conditioner does not heat or cool well. | ■ Clean the filter. (Airflow is |
reduced when the filter is dirty or clogged.)
■ Check the temperature adjustment and adjust the set temperature.
■ Make sure that there is plenty of space around the outdoor unit. Is the indoor unit air intake or outlet blocked?
■ Has a door or window been left open?
When heating operation starts, warm air does not blow from the indoor unit
soon.| ■ Warm air does not blow until the indoor unit has sufficiently warmed
up.
During heating mode, the air conditioner stops before the set room tem-
perature is reached.| ■ When the outdoor temperature is low and the humidity
is high, frost may form on the outdoor unit. If this occurs, the outdoor unit
performs a defrosting operation. Normal operation should begin after approxi-
mately 10 minutes.
Airflow direction changes during operation or airflow direction cannot be
set.
| ■ During cooling mode, the vanes automatically move to the horizontal (down) position after 1 hour when the down (horizontal) airflow direc- tion is selected. This is to prevent water from forming and dripping from the vanes.
■ During heating mode, the vanes automatically move to the horizontal airflow direction when the airflow temperature is low or during defrosting mode.
When the airflow direction is changed, the vanes always move up and down past
the set position before finally stopping at the position.| ■ When the airflow
direction is changed, the vanes move to the set position after detecting the
base position.
A flowing water sound or occasional hissing sound is heard.| ■ These sounds
can be heard when refrigerant is flowing in the air conditioner or when the
refrigerant flow is changing.
A cracking or creaking sound is heard.| ■ These sounds can be heard when parts
rub against each due to expansion and contraction from temperature changes.
The room has an unpleasant odor.| ■ The indoor unit draws in air that contains
gases produced from the walls, carpeting, and furniture as well as odors
trapped in clothing, and then blows this air back into the room.
A white mist or vapor is emitted from the indoor unit.| ■ If the indoor
temperature and the humidity are high, this condition may occur when operation
starts.
■ During defrosting mode, cool airflow may blow down and appear like a mist.
Water or vapor is emitted from the outdoor unit.| ■ During cooling mode, water may form and drip from the cool pipes and joints.
■ During heating mode, water may form and drip from the heat exchanger.
■ During defrosting mode, water on the heat exchanger evaporates and water vapor may be emitted.
“ ” appears in the remote controller display.| ■ During central control, “ ”
appears in the remote controller display and air conditioner operation cannot
be started or stopped using the remote controller.
When restarting the air conditioner soon after stopping it, it does not
operate even though the ON/OFF button is pressed.| ■ Wait approximately 3
minutes. (Operation has stopped to protect the air conditioner.)
Air conditioner operates without the ON/OFF button being pressed.| ■ Is the on
timer set?
Press the ON/OFF button to stop operation.
■ Is the air conditioner connected to a central remote controller?
Consult the concerned people who control the air conditioner.
■ Does “ ” appear in the remote controller display?
Consult the concerned people who control the air conditioner.
■ Has the auto recovery feature from power failures been set?
Press the ON/OFF button to stop operation.
Air conditioner stops without the ON/OFF button being pressed.| ■ Is the off
timer set?
Press the ON/OFF button to restart operation.
■ Is the air conditioner connected to a central remote controller?
Consult the concerned people who control the air conditioner.
■ Does “ ” appear in the remote controller display?
Consult the concerned people who control the air conditioner.
Remote controller timer operation cannot be set.| ■ Are timer settings
invalid?
If the timer can be set, or appears in the remote controller display.
“Please Wait” appears in the remote controller display.| ■ The initial
settings are being performed. Wait approximately 3 minutes.
An error code appears in the remote controller display.| ■ The protection
devices have operated to protect the air conditioner.
■ Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure to
provide the dealer with the model name and information that appeared in the
remote controller display.
Draining water or motor rotation sound is heard.| ■ When cooling operation
stops, the drain pump operates and then stops. Wait approximately 3 minutes.
---|---
Noise is louder than specifications.| ■ The indoor operation sound level is
affected by the acoustics of the particular room as shown in the following
table and will be higher than the noise specification, which was measured in
anechoic room.| | High sound absorbing rooms| Normal rooms| Low sound
absorbing rooms
---|---|---|---
Location examples| Broadcasting studio, music room, etc.| Reception room,
hotel lobby, etc.| Office, hotel room
Noise levels| 3 – 7 dB| 6 – 10 dB| 9 – 13 dB
Nothing appears in the wireless remote controller display, the display is
faint, or signals are not received by the indoor unit unless the remote
controller is close.| ■ The batteries are low. Replace the batteries and press
the Reset button.
■ If nothing appears even after the batteries are replaced, make sure that the batteries are installed in the correct directions (+, –).
After battery installation/replacement of remote controller, part of function
cannot be used.| ■ Please check that the clock setting is completed. If clock
setting is not done, please complete.
The operation lamp near the receiver for the wireless remote controller on the
indoor unit is blinking.| ■ The self diagnosis function has operated to
protect the air conditioner.
■ Do not attempt to repair this equipment by yourself. Turn off the power switch immediately and consult your dealer. Be sure to provide the dealer with the model name.
The indoor unit which is not operating becomes warm and a sound, similar to water flowing, is heard from the unit.| ■ A small amount of refrigerant continues to flow into the indoor uniteven though it is not operating. (Connected with MXZ/Branch box)
Specifications
PCA-M·KA Series
Fan airflow rate (Low-Middle2-Middle1-High)
<m3/min>
| 10-11-12-14| 10-11-13-15| 15-16-17-19| 16-17-18-20| 22-24-26-28|
23-25-27-29| 24-26-29-32
Noise level (Low -Middle2-Middle1-High)|
Net weight|
Model| M35| M50| M60| M71| M100| M125| M140
---|---|---|---|---|---|---|---
Cooling Capacity| sensible| Prated,c
latent| Prated,c
Heating Capacity| Prated,h
Total electric power input| Pelec
Sound power level
(per speed setting, if applicable)
| LWA
EU DECLARATION OF CONFORMITY
MITSUBISHI ELECTRIC CORPORATION
TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
hereby declares under its sole responsibility that the air conditioner(s) and heat pump(s) for use in residential, commercial, and light-industrial environments described below:
MITSUBISHI ELECTRIC, PCA-M35KA, PCA-M50KA, PCA-M60KA, PCA-M71KA, PCA- M100KA, PCA-M125KA, PCA-M140KA*
is/are in conformity with provisions of the following Union harmonisation legislation.
2014/35/EU: Low Voltage
2006/42/EC: Machinery
2014/30/EU: Electromagnetic Compatibility
2011/65/EU, (EU) 2015/863 and (EU) 2017/2102: RoHS Directive
2009/125/EC: Energy-related Products and Regulation (EU) No 206/2012
Only 35/50/60/71/100
UK DECLARATION OF CONFORMITY
MITSUBISHI ELECTRIC CORPORATION
TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
hereby declares under its sole responsibility that the air conditioners and
heat pumps described below for use in residential, commercial and light-
industrial environments:
MITSUBISHI ELECTRIC, PCA-M35KA, PCA-M50KA, PCA-M60KA, PCA-M71KA, PCA-
M100KA, PCA-M125KA, PCA-M140KA*
Note: Its serial number is on the nameplate of the product.
Legislation
Electrical Equipment (Safety) Regulations 2016
Supply of Machinery (Safety) Regulations 2008
Electromagnetic Compatibility Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
The Ecodesign for Energy-Related Products and Energy Information *Only
35/50/60/71/100
This product is designed and intended for use in the residential, commercial and light-industrial environment.
Importer in European and surrounding region.
Mitsubishi Electric Europe B.V.
Capronilaan 34, 1119 NS, Schiphol Rijk, The Netherlands
French Branch
2, Rue De LʼUnion, 92565 RUEIL MAISON Cedex
German Branch
Mitsubishi-Electric-Platz 1 40882 Ratingen North Rhine-Westphalia Germany
Belgian Branch
8210 Loppem, Autobaan 2, Belgium
Irish Branch
Westgate Business Park, Ballymount Road, Upper Ballymount, Dublin 24, Ireland
Italian Branch
Via Energy Park, 14 20871 Vimercate (MB), Italy
Norwegian Branch
Gneisveien 2D, 1914 Ytre Enebakk, Norway
Portuguese Branch
Avda. do Forte 10, 2794-019 Carnaxide, Lisbon, Portugal
Spanish Branch
Av. Castilla, 2 Parque Empresarial San Fernando – Ed. Europa, 28830 San
Fernando de Henares (Madrid), Spain
Scandinavian Branch
Hammarbacken 14, P.O. Box 750, SE-19127, Sollentuna, Sweden
UK Branch
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, United Kingdom
Polish Branch
Krakowska 50, PL-32-083 Balice, Poland
MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A.Ş
Şerifali Mahallesi Kale Sokak No: 41 34775 Ümraniye, İstanbul, Turkey
HEAD OFFICE: TOKYO BUILDING, 2-7-3. MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>