RAIDER RD-GG13 Gasoline Generator Inverter Instruction Manual
- May 15, 2024
- Raider
Table of Contents
- Description of elements
- Dear Customer
- Technical Data
- Safety Guidelines
- Purpose of the unit
- Working with the device
- STARTING THE ENGINE
- GENERATOR USE
- STOPPING THE ENGINE
- CLEANING, MAINTENANCE AND STORAGE
- TROUBLESHOOTING
- Environmental protection
- exploded drawing
- DECLARATION OF CONFORMITY
- DECLARATION OF CONFORMITY
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RAIDER RD-GG13 Gasoline Generator Inverter
Description of elements
- Economic mode
- Switch on/off
- Indicators’ panel
- AC Output Socket
Always wear hearing protection!
Refer to instruction manual / booklet!
Wear safety glasses!
Wear dust mask!
The pictures are for illustration purpose. The pattern shown may not be exactly the same as the machine you purchased.
Dear Customer
Congratulations on your purchase of the fastest growing brand of electric,
gasoline and pneumatic machines – RAIDER. Properly installed and operated,
RAIDER is a safe and reliable machine and will be a pleasure to use. For your
convenience, an excellent service network has been set up with 45 service
stations throughout the country.
Before using this gasoline brush cutter please carefully acquaint to these
“instructions for use”.
In interest of your safety and to ensure proper use, read these instructions
carefully, including the recommendations and warnings in them. To avoid
unnecessary errors and accidents, it is important that these instructions must
remain available for future reference to all who will use the machine. If you
sell it to a new owner “Instructions for Use” must be submitted along with it,
so that new owner can meet with the relevant safety measures and operating
instructions.
EUROMASTER Import Export Ltd. is an authorized representative of the
manufacturer and owner of the trademark RAIDER.
Address: Sofia City 1231, Bulgaria “Loskop shamuses” Blvd. 246, tel +359
700 44 155, +359 2 934 10 10, www.raider.bg;
www.euromasterbg.com; e-mail:
info@euromasterbg.com.
Since 2006 the company introduced the system of quality management ISO
9001:2008 with scope of certification: Trade, import, export and servicing of
hobby and professional electrical, mechanical and pneumatic tools and general
hardware. The certificate was issued by Moody International Certification Ltd,
England.
Technical Data
parameter | unit | value |
---|---|---|
Model | – | RD-GG13 |
Engine type | – | gasoline, four stroke, air-cooled single cylinder |
Engine displacement | cm3 | 223 |
Engine power: | kW | 4,5 |
Idle speed | min-1 | 3800 |
AC output current | V | 230 |
Frequency | Hz | 50 |
How to start the engine | – | electric start/manual magnetrc start system |
Volume of the fuel tank | L | 9 |
Fuel | Unleaded petrol | |
Fuel consumption | L / KMh | 0.380 |
Ignition system | non-contact transistor | |
Sound pressure level LpA K = 3 dB (A) | dB(A) | 70 dB(A) |
Sound power level measured LwA K = 3 dB (A) | dB(A) | 92.6 dB(A) |
Dimensions | mm | 590435440mm |
Weight | kg | 37 |
Safety Guidelines
In use of the devices must comply with certain precautions associated with safety to prevent injury and damage. For this purpose, carefully read the safety instructions. In case you need to pass the instrument of others, please hand them this instruction manual. “Euro aster Import Export” Ltd accepts no liability for accidents or damage that occurs due to non-observance of this manual and safety instructions.
-
Should not be made any changes to the generator. For maintenance and accessories should be used only original parts.
-
Altering the engine speed beyond the factory setting is prohibited.
-
The use of the generator for industrial supply.
-
Connecting the generator to the building installation is prohibited.
-
It is prohibited to connecting two or more generator with each other.
-
Exhaust gases must not breathe because of the risk of poisoning.
-
Do not let near children and animals when the generator is running.
-
Risk of burns – do not touch the exhaust (muffler) and the drive unit.
-
Gasoline and gasoline vapors are flammable respectively explosive.
-
Never use electric generator in rooms with combustible materials – risk of explosion.
Do not use a generator indoors, since the engine produces poisonous gases at work. -
Place the generator at least 1 meter away from buildings and other equipment, flammable substances (tubes and barrels of gasoline and other fuels)
-
Never smoke near the generator.
-
Try not to spill fuel around the opening of the tank. In case spill clean carefully and wait enough to dry, then do not start the car engine.
-
During transport generating must be secured against slipping and overturning.
-
If you want to ship the unit, empty before the petrol tank
-
Place generator on a flat surface. The placement of the generator at an incline may lead to spillage.
-
When transporting or refueling always turn off the engine.
-
Do not charge near open lights, fire or sparks flying, empty tank
-
Do not touch any mechanically driven or hot parts. Do not remove any protective coating.
-
Do not expose the generator under the influence of rain or high humidity.
-
The generator is driven by an internal combustion engine, which in the area of the tailpipe (on the opposite side of the outlet) and the exhaust outlet induces incandescence.
Avoid the proximity of these surfaces because of risk of skin burns. -
Beware of electrical hazards. Outdoor use only authorized for that extension cords.
The lengths of the wires to the consumer should be as short as possible. -
Do not plug the generator into household electricity – it can cause damage to the generator or other electrical appliances in the home.
-
Do not touch the generator with wet hands while working. Electric power wires and included appliances must be in perfect condition.
-
Include only those items whose data voltage are compatible with the output voltage of the electric generator. Do not include devices with maximum power greater than 2.5 kW.
-
Never connect appliances to the generator before you have started
-
Use only insulated protective devices. Do not touch any mechanically driven or hot parts. Do not remove any protective coating.
-
The generator must not be exposed to moisture or dust ..
-
Gasoline is very flammable! Store gasoline only in designated containers
-
Charge petrol only outdoors and do not smoke while charging
-
While the engine is running or still warm, do not remove the cap of the petrol tank and charge the generator with fuel. When loading use funnels or tubes appropriate for that not to spill gasoline on generator. If you spill fuel dry it immediately.
-
Do not store the generator in a closed room, when there is fuel in the tank. Vapors may cause fire.
-
Empty fuel tank and carburetor if you will not use the generator for a long time or will you transport-in support.
-
Do not use gasoline to clean the machine and engine.
-
Keep the used oil in the original package and hand processing of the designated areas.
Purpose of the unit
Generator RAIDER RD-GG13 is intended to supply hand-held power tools or
appliances with maximum power to about 4500W (notice that some appliances have
larger starting power than the one that is marked for them).
The generator is suitable for powering computers and other precision
technique.
The generator is equipped with а 2 x AC 230 V.
The generator is equipped with an automatic voltage regulator (AVR).
Working with the device
Check the engine oil level.
Before starting the gasoline generator, make sure that no consumers are
plugged.
Check the oil – should be SAE 10W-30 or SAE 15W40.
Running the engine with insufficient oil can cause serious engine damage.
NOTE: The Low Oil Alarm System will automatically stop the engine before
the oil level falls below the safe limit. However, to avoid the inconvenience
of an unexpected shutdown, it is still advisable to visually inspect the oil
level regularly.
Check the fuel level.
Use automotive gasoline (Unleaded or low leaded is preferred to minimize
combustion chamber deposits). If the fuel level is low, refuel the fuel tank
until the level increased to the specified mark.
Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust
or water in the fuel tank.
After refueling, tighten the fuel tank cap
- Gasoline is extremely flammable and is explosive under certain conditions.
- Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored.
- Do not overfill the fuel tank (there should be no fuel above the upper limit mark).
- After refueling, make sure the tank cap is closed properly and securely.
- Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite, if any fuel is spilled, make sure the area is dry before starting the engine.
- Avoid repeated or prolonged contact with skin or breathing of vapor. KEEP OUT OF REACH OF CHILDREN.
Check the air cleaner
Check the air cleaner element to be sure it is clean and in good condition.
Loosen the cover screw and remove the left side maintenance cover.
Press the latch tab on the top of the air cleaner body, remove the air cleaner
cover, check the element. Clean or replace the element if necessary.
Never run the engine without the air cleaner. Rapid engine wear will result
from contaminants, such as dust and dirt, being drawn through the carburetor,
into the engine.
STARTING THE ENGINE
Ensure sufficient ventilation of the unit.
Ensure that the ignition cable is attached to the spark plug.
Consider the immediate environment of the electric generator.
Turn off any electrical appliance switched from electric generator.
When starting, wear protective gloves.
-
Turn the fuel cap lever fully clockwise to the “ON” position. Turn the fuel cock to the “ON” position.
-
Turn the engine switch to the “ON” position.
-
Move the choke lever to the “START” position.
NOTE: Do not use the choke when the engine is warm or the air temperature is high.
-
Pull the starter grip until resistance is felt, the pull the starter grip briskly toward the arrow as shown below.
- Do not allow the starter grip to snap back, Return it slowly by hand
-
Move the choke lever to the “RUN” position after the engine warms up.
- If the engine stops and will not restart, check the engine oil level before trouble shooting in other areas.
High altitude operation
At high altitude, the standard carburetor air-fuel mixture will be excessively
rich.
Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter
main fuel jet in the carburetor and readjusting the pilot screws. If you
always operate the generator at altitudes higher than 1,500 m (5,000 feet)
above sea level, have your authorized dealer perform these carburetor
modifications.
Even with suitable carburetor jetting, engine horsepower will decrease
approximately 3.5% for each 300m (1,000 feet) increase in altitude. The affect
of altitude on the horsepower will be greater than this if no carburetor
modification is made.
- Operation of the generator at an altitude lower than the carburetor is jetted for may result in reduced performance, overheating, and serious engine damage caused by an excessively lean air/fuel mixture.
GENERATOR USE
Be sure to ground the generator when the connected equipment is grounded. Ground Terminal.
To prevent electrical shock from faulty appliances, the generator should be
rounded.
Connect a length of heavy wire between the generator’s ground terminal and an
external ground source. Connections for standby power to a building’s
electrical system must be made by a qualified electrician and must comply with
all applicable laws and electrical codes.
Improper connections can allow electrical current from the generator to back
feed into the utility lines. Such back feed may electrocute utility company
workers or others who contact the lines during a power outage, and when
utility power is restored, the generator may explode, burn, or cause fires in
the building’s electrical system.
-
Start the engine and the operating mode indicator will come on
-
Make sure the appliance to be used is off and switch on the appliance.
When overloading, the overload indicator comes on, switch off the appliance as it may be damaged and shorten the life of the generator. Make sure that all appliances are in good working order before connecting them to the generator. If an appliance starts to malfunction, becomes sluggish, or stops suddenly, immediately switch off the engine generator circuit breaker. -
For best effect and extend the life of the generator, the new generator should normally run 20 hours under 50% load.
EXIT & OVERLOAD
- If the generator is overloaded (above maximum) or if there is a break in the connected device, the connected device must be switched off immediately.
- Turn off the engine if the overload indicator comes on and check the overload source.
- Before connecting the appliance to the generator, check that it is in good condition and that its electrical power does not exceed that of the generator. Then connect the power cord of the appliance and start the engine.
Oil indicator
- The oil indicator is designed to prevent engine damage caused by insufficient oil in the crankcase. Before the oil level in the crankcase falls below the hazardous limit, the oil indicator starts to illuminate automatically and the engine will stop (the engine switch will remain in the “ON” position).
- If the low oil alarm system switches off the engine, the oil indicator (red) will come on. If this happens, add engine oil.
STOPPING THE ENGINE
To stop the engine in an emergency, turn the engine switch to the “OFF”
position.
IN NORMAL USE:
-
Switch off the connected equipment and pull the inserted plug out.
-
Turn the engine switch to the “OFF” position.
-
Turn the fuel cap lever fully clockwise to the “OFF” position. Turn the fuel cock to the “OFF “ position.
CLEANING, MAINTENANCE AND STORAGE
- Keep safety equipment, air slots and the motor housing contaminated by dust and dirt as possible.
- Clean the unit with a clean cloth or with compressed air at low pressure.
- We recommend that you clean the unit after each use.
- Periodically check the condition of the air filter, which is made of foam rubber and is cleaned by washing with water.
- Periodically check the oil level in the generator system.
- The generator must be kept clean and dry place, should be prepared for storage as follows:
- Place the tap of gasoline to “OFF”
- Unscrew and remove the filter cup
- Place the tap to “ON” drain the gasoline from the tank
- Screw the cup back
- Start the engine and let it run until it stops. This will remove the fuel from the carburetor
- Pull the starter handle slowly until you feel the effort. This is the compression point. In this position the suction and discharge valves are closed, which helps prevent corrosion in the cylinder.
TROUBLESHOOTING
Damage | Check: |
---|---|
The engine can not be started. | Spark plug The fuel level |
The position of the stopcock Check the oil level
Engine starts and runs normally, but does not send electricity.| Switcher of
the electrical feed
The generator has little or no tension.| Reason:
Regulator or capacitor is defective. Activated overcurrent protection.
A dirty air filter.
Environmental protection
Environmental protection. In view of environmental protection electrical
appliances, additional accessories and packing must be subject to appropriate
processing for reuse of the compound materials.
According the European Guideline 2012/19//EC for Waste Electrical and
Electronic Equipment and its implementation into national right, power tools
that are no longer usable must be collected separately and disposed of in an
environmentally correct manner.
exploded drawing
DECLARATION OF CONFORMITY
Euro aster Import Export Ltd.
Address: Sofia 1231, Bulgaria, 246 Loskop shamuses Blvd.
Product: Gasoline Generator Inverter
Trademark: RAIDER
Model: RD-GG13
is designed and manufactured in conformity with following Directives:
2006/42/EC of the European Parliament and the Council dated 17-th May 2006 on
machinery
2025/30/EU of the European parliament and of the council of 26 February 2025
on the harmonisation of the laws of the Member States relating to
electromagnetic compatibility;
2000/14/EC of the European Parliament and of the Council of 8 May 2000, on the
approximation of the laws of the Member States relating to the noise emission
in the environment by equipment for use outdoors.
Noise emission according to standard EN ISO 3744:2010.
Measured sound power level: 92.6 dB(A)
Guaranteed sound power level LWA: 96 dB(A)
Notified body:
0036. TÜV SÜD Industry Service GmbH.
Wes tend Straße 199. 80686 München. Germany
The product fulfils the essential requirements of the following standards:
EN 12601:2010
EN 55012:2007/A1:2009
EN ISO 8528-13:2016
Place & Date of Issue:
Sofia, Bulgaria
July 20 2023
Brand Manager:
DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in conformity and accordance with the following standards and regulations:
Customer Support
EUROMASTER IMPORT EXPORT LTD
1231, Sofia, Bulgaria, 246 Loskop shoes Blvd.,
tel.: +359 700 44 155
fax: + 359 2 934 00 90
www.euromasterbg.com e-mail: info@euromasterbg.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>