IFIXIT MFC-490CW Brother Scanning Glass Replacement Instruction Manual

June 3, 2024
IFIXIT

IFIXIT MFC-490CW Brother Scanning Glass Replacement

IFIXIT-MFC-490CW-
Brother-Scanning-Glass-Replacement-product

INTRODUCTION

The print head may need replacing if failed attempts at cleaning the print head still produces faded or spotted prints or documents. Use this guide to replace a malfunctioning print head of your Brother MFC-490CW.

TOOLS:

  • Phillips #2 Screwdriver (1)
  • Spudger (1)

ASSEMBLING INSTRUCTION

Step 1 — Remove screws holding the front panel

  • Use a Phillips #2 screwdriver to remove the three 12.1 mm screws holding the control panel in place.IFIXIT-MFC-490CW-Brother-Scanning-Glass-Replacement-fig-1

Step 2 — Unplug the panel from the rest of the printerIFIXIT-MFC-490CW-
Brother-Scanning-Glass-Replacement-fig-2

  • Lift up the front panel from the device.
  • Gently lift up and pull out the data cables that attach the panel to the printer.

Step 3 — Separate the arm holding scanner unitIFIXIT-MFC-490CW-Brother-
Scanning-Glass-Replacement-fig-3

Before removing the unit, apply 2 or 3 pieces of tape to secure the top and bottom of the unit.

  • Lift the scanner unit.
  • Gently twist the top portion of the arm.
  • The top portion should release from the scanner unit.
  • Rotate the arm approximately 45 degrees to remove the bottom portion of the arm from the device.

Step 4 — Remove the scanner unit from the deviceIFIXIT-MFC-490CW-Brother-
Scanning-Glass-Replacement-fig-4

  • Slide the unit either to the left or right and begin to push the unit away from the device.
  •  Once one hinge is separated from the device, begin to remove the other hinge from the device.
  • Gently place the unit on the work surface.

Step 5 — Remove left wire panelsIFIXIT-MFC-490CW-Brother-Scanning-Glass-
Replacement-fig-5

While it is not necessary to use a prying tool, using one may make it easier to lift the panels.

  • Starting from the back of the printer, use the exposed portion of the panel to gently pry the panel up from the printer.

Step 6 — Remove right wire panelIFIXIT-MFC-490CW-Brother-Scanning-Glass-
Replacement-fig-6

  • From the back of the device, use the exposed portion of the panel to begin to lift the panel away from the device.

Step 7 — Removing left set of power cablesIFIXIT-MFC-490CW-Brother-
Scanning-Glass-Replacement-fig-7

Before removing the cables, create a diagram of the locations of the different cables with some tape or Post-Its.

  • Remove the three power cables that connect the scanner to the motherboard.

Step 8 — Remove the ground wireIFIXIT-MFC-490CW-Brother-Scanning-Glass-
Replacement-fig-8

  • Use a Phillips #2 screwdriver to remove the 12.1 mm screw to remove the ground wire.

Step 9 — Remove data cableIFIXIT-MFC-490CW-Brother-Scanning-Glass-
Replacement-fig-9

  • Gently pull the data cable away from the motherboard.
  • Slide the cable out of the slots to remove the cable from the device.
  • The scanner unit is now separated. Place the unit and ground screw in a safe part of the workspace until needed for re-assembly.

Step 10 — Remove front screws of the device coverIFIXIT-MFC-490CW-
Brother-Scanning-Glass-Replacement-fig-10

  • Use the Phillips #2 screwdriver to remove the three 14.1 mm screws.
  • Use the Phillips #2 screwdriver to remove the 12.1 mm screw.

Step 11 — Remove the paper trayIFIXIT-MFC-490CW-Brother-Scanning-Glass-
Replacement-fig-11

  • Pull the paper tray away from the device.

Step 12 — Remove center screw near the USB and ethernet portsIFIXIT-MFC-
490CW-Brother-Scanning-Glass-Replacement-fig-12

  • Use the Phillips #2 screwdriver to remove the 8 mm screw at the center of the device.

Step 13 — Remove rear panel screwsIFIXIT-MFC-490CW-Brother-Scanning-
Glass-Replacement-fig-13

  • Use the Phillips #2 screwdriver to remove the two 14.1 mm screws holding the panel in place.

Step 14 — Remove red power cableIFIXIT-MFC-490CW-Brother-Scanning-Glass-
Replacement-fig-14

This cable needs to be removed to allow the removal of the device cover.
Gently remove the red power cable from the motherboard.

Step 15 — Remove paper jam clear coverIFIXIT-MFC-490CW-Brother-Scanning-
Glass-Replacement-fig-15

  • Gently push the upper-left tab of the cover and separate the hinged portion of the cover from the rest of the device.
  • Once one side is free, slide the other side away from the device.
  • Pull the cover away from the device.

Step 16 — Remove the device coverIFIXIT-MFC-490CW-Brother-Scanning-Glass-
Replacement-fig-16

  • Using a spudger, loosen the two clipped portions of the cover located at the back-center of the cover.
  • Once the clips are free the rest of the cover can be lifted up and away from the device.

Step 17 — Release the clear print head guide wireIFIXIT-MFC-490CW-
Brother-Scanning-Glass-Replacement-fig-17

  • Gently pull the wire to the left so the end of the wire is released.
  • Slide the wire away from the top of the print head unit.

Step 18 — Releasing the print head from the carriageIFIXIT-MFC-490CW-
Brother-Scanning-Glass-Replacement-fig-18.

  • Using a spudger, press down on the plastic housing of the carriage that the print head rests on.
  • Slide the print head to the left of the device.

Step 19 — Removing the print head from the rails.IFIXIT-MFC-490CW-
Brother-Scanning-Glass-Replacement-fig-19

  • Slide the print head until it is at the end of the rail.
  • Push the print head unit towards the back of the device and lift the unit from the back rail.
  • Gently release the other end of the print head to remove it from the front rail.

Step 20 — Release the print heat conveyorIFIXIT-MFC-490CW-Brother-
Scanning-Glass-Replacement-fig-20

  • Using the spudger, press the spring section of the white pulley.
  • Release the conveyor from the pulley while the spring is still compressed.
  • Remove the conveyor from the gear on the other side of the device.
  • Optional: Slide the conveyor off the print head.

Step 21 — Opening the top print head cover.IFIXIT-MFC-490CW-Brother-
Scanning-Glass-Replacement-fig-21

  • Squeeze the ends of the cover, then release the cover, revealing the processor unit.

Step 22 — Remove the data cable from the print head processing unit .IFIXIT-MFC-490CW-Brother-Scanning-Glass-Replacement-
fig-22

  • Slide the black cap away from the port.
  • Slide the data cable out of the port.

Step 23 — Remove print head processor unitIFIXIT-MFC-490CW-Brother-
Scanning-Glass-Replacement-fig-23

  • Lift the processor out of the print head.
  • Slide the cables attached to the processor away from the print head unit.

Step 24 — Remove the inkjet nozzle unit.IFIXIT-MFC-490CW-Brother-
Scanning-Glass-Replacement-fig-24

  • Remove the metal clip holding the nozzle unit.
  • Lift the unit from the rest of the print head unit.

To reassemble your device, follow these instructions in reverse order

Documents / Resources

| IFIXIT MFC-490CW Brother Scanning Glass Replacement [pdf] Instruction Manual
MFC-490CW Brother Scanning Glass Replacement, MFC-490CW, Brother Scanning Glass Replacement, Scanning Glass Replacement, Glass Replacement, Replacement
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

IFIXIT User Manuals

Related Manuals