legrand Cool Master Liquid Cooling Kit
Product Information
Specifications
- Product Name: CoolAutomation Integration Solution
- Manufacturer: CoolAutomation
- Compatibility: Vantage Control Systems
- Supported HVAC Systems: VRF, VRV, Split, Mini-Split, and more
- Communication Protocols: Open communication protocols
Product Usage Instructions
Overview
The CoolAutomation Integration Solution allows seamless integration of HVAC
Climate control into Vantage Control Systems. It provides full control over
HVAC systems through Vantage digital keypads, touchscreens, mobile apps,
motion sensors, and timers.
About CoolAutomation
CoolAutomation specializes in climate and IoT technologies connecting
various HVAC systems to local networks using opencommunication protocols. This
enables interoperability between closed HVAC systems and external systems for
efficient climate control.
Compatible Vantage System Configuration
Initial Requirements: CoolMaster Auto Discovery (consult your A/C contractor/installer)
System Diagram
A diagram illustrating the connection between HVAC Systems, Vantage
InFusion Controller, CoolMaster, CoolPlug and Hub, CooLinkBridge, and the
Local Area Network.
HVAC Systems and Compatibility
Detailed information on connecting CoolAutomation devices to various HVAC
systems like Heat Pumps, Underfloor Heating, Zoning Systems, Unitary/DX, Mini-
Split/Multi-Split Systems, and VRF Systems.
Vantage Integration Setup
- Project Settings – Fill out Equinox Mobile Passcode and Admin PIN.
- Add the Vantage HVAC-IU driver to the project using Object Explorer.
- Follow additional setup details provided in the manual.
FAQ
-
Q: What CoolAutomation devices are compatible with the Vantage InFusion communication driver?
A: The Vantage InFusion communication driver is compatible with CoolMaster Product Family, CoolPlug, CooLinkHub, and CooLinkBridge devices. -
Q: Where can I find online documentation and tutorials for connecting CoolAutomation devices to HVAC systems?
A: Visit CoolAutomation’s Support Center for detailed online documentation, videos, and step-by-step tutorials on integrating CoolAutomation devices with HVAC systems.
Integration Guide
CoolAutomation and Vantage
OVERVIEW
CoolAutomation and Legrand have partnered up to provide a seamless integration
solution for HVAC Climate control as part of the Vantage Control Systems.
The CoolAutomation devices make it easy for compatible HVAC
systems to communicate with a Vantage InFusion System.
They allow full HVAC control through Vantage digital keypads, touchscreens,
and a mobile app, in addition to motion sensors and timers. It can also
provide feedback of the actual temperature and setpoints on Equinox
touchscreens.
ABOUT COOLAUTOMATION
CoolAutomation’s solutions are the next evolution of climate and IoT
technologies, connecting VRF, VRV, Split, Mini-Split, and other HVAC systems
to the local network with open communication protocols. This allows closed and
proprietary HVAC systems to communicate with external systems, offering
unmatched management of an environment’s climate control.
To learn more, visit: https://coolautomation.com/
COMPATIBLE VANTAGE SYSTEM CONFIGURATION
- Certified to work with Equinox products (EQ41, EQ73, and Equinox mobile app, EQ40), using the climate widget
- Certified to work with keypads by the usual task assignment
- Certified with InFusion Controller II, Design Center 4.5, and Equinox 1.6.3
- NOT compatible with older TPTs like 650
- The EQ40 is limited to offering setpoint and HVAC mode, and sets HVAC parameters by assigning it to a digital keypad button
- Keypads can be setup to operate HVAC parameters through the standard HVAC control procedures in Design Center
INITIAL REQUIREMENTS
- Compatible HVAC unit (per compatibility list)
- Total number of HVAC indoor units and HVAC outdoor units to connect
- Network connection to the Local Area Network (LAN) router (DHCP or Static IP assigned)
- CoolAutomation Setup Utility (Free download here: https://support.coolautomation.com/hc/en-us/articles/5139558696733-Quick-Installation-Tool )
- IP Address of the CoolAutomation Device (see FAQ, page 25)
- TCP Port Number of the CoolAutomation device (default TCP port number 10102)
- HVAC Indoor Unit (IDU) unique address on the CoolAutomation device to be able to use correct zone parameters on the DC file (example: L1.100, L3.201, etc)
- For VRF and VRV systems – the HVAC system centralized addressing has to be set and commissioned on the units for the CoolMaster Auto Discovery (ask your A/C contractor/installer)
SYSTEM DIAGRAM
CoolAutomation devices will always connect directly to the air conditioning systems, via two wire communication lines. In some cases, the connection will happen at the HVAC Indoor unit, and in other cases it will happen at the HVAC Outdoor units. The CoolAutomation device will communicate with Vantage over a TCP port connection on the Local Area Network. No need for external Cloud- based connections – making the integration and communication reliable, secure, fast and immune to Internet connection issues.
The CoolAutomation line-up of devices is designed for covering a wide range of HVAC systems, HVAC manufacturers and HVAC technologies. The Vantage InFusion communication driver for CoolAutomation is compatible with the following CoolAutomation devices:
- CoolMaster Product Line (CoolMasterNet, CoolMaster, CoolMasterPro)
- CooLinkHub (with CoolPlugs)
- CooLinkBridge (with Radiant Heat, Conventional Thermostats, etc)
HVAC SYSTEMS AND COMPATIBILITY
The connection of the CoolAutomation device to the HVAC system depends on HVAC system type, manufacturer, and overall project specifics. Visit CoolAutomation’s Support Center for online documentation, videos, and step-by- step tutorials on how to connect the CoolAutomation Device to the HVAC system.
INTEGRATION PLATFORMS
COOL AUTOMATION DEVICE HVAC COMPATIBILITY LIST
-
Visit the CoolAutomation Support Center for the latest list of Compatible HVAC systems in your market:
https://support.coolautomation.com/hc/en- us/sections/5009071299101-Compatibility -
CoolMaster HVAC Compatibility List:
https://support.coolautomation.com/hc/en-us/articles/5009159720349 -CoolMaster-HVAC-Home-Automation-compatibility- -
CoolPlug & CooLinkHub Compatibility List
https://support.coolautomation.com/hc/en-us/articles/5038125257373-CoolPlug- CooLinkHub-HVAC-Home-Automation-compatibility -
CooLinkBridge Compatibility List:
https://support.coolautomation.com/hc/en-us/articles/5038458341661 -CoolLinkBridge-HVAC-Home-Automation-compatibility
SUPPORTED FEATURES
SUPPORTED CONTROL FEATURES:
- Operation Mode (Cool / Heat / Auto)
- Setpoint (C or F)
- Fan Speed
- Dry Mode (dehumidify)
- Fan Mode (procedure fan_on)
SUPPORTED FEEDBACK FEATURES:
- Operation Mode
- Setpoint (Cool and heat and auto are always the same)
- Fan Speed
- Operation Status (heat/cool/idle)
- Indoor Temperature – Possibility to use an external
- Outdoor Temperature – If using an external sensor
- Dry Mode On, Fan Mode On*
WIDGETS
Please see the following examples of the widgets on Equinox devices.
VANTAGE INTEGRATION SETUP
DESIGN CENTER SETUP PROCESS
-
Project Settings – Click on Settings | Project Information | Owner (tab).
-
Fill out the Equinox Mobile Passcode: (alpha/numeric)
-
Fill out the Equinox Admin PIN: (numeric)
-
Add the driver – In the Object Explorer, select Drivers>Vantage and double-click or drag the Vantage HVAC-IU to add it to the project.
-
Add Port – Select a new TCP port.
-
For the TCP port, add the CoolDevice IP address (you can find the IP Address of your CoolDevice directly on the CoolMaster Touchscreen or using the CoolAutomation Setup Utility).
-
Add the Driver to the Data, Write, Connect, and Disconnect fields of the port.
-
Leave Manual Connect unchecked.
-
Set Port – Set the port to 10102 (This must match what is configured on the CoolDevice, which comes with Default TCP Port 10102)
-
Line Settings : Set the Device Type – Use the drop-down list to select the brand of your HVAC equipment connected to the Line Number used on the CoolAutomation device.
-
Line Settings : Set the Line Number – Set (1-8) for each physical HVAC communication line added on the CoolAutomation device. Default is Line Number 1.
IMPORTANT NOTES:- When using a CooLinkHub with Wireless CoolPlugs connected: Use Line Number 2
- When using a CooLinkHub with Wired CoolPlugs connected: Use Line Number 5
-
Add Zones – Add one zone for each individual UIDs on the CoolAutomation Device Line (see Tech Notes for more information)
-
Zone Settings – Set the main Zone Number (000-FFF) for each zone added to that Line. (3 digits, should match the ID on the CoolAutomation Device Line)
-
Set the Areas – Change the area where the interface is installed. Each zone can be assigned its own area as well.
-
Optional – if zones are grouped on the CoolAutomation Device, use the + icon to add them to the driver.
More details under Important Notes and Recommendations (pg 28). -
Serial Number – Enter the serial number that is found on the back of the CoolAutomation Device (also printed on the box). This is required for establishing the TCP/IP connection. Example of Serial Number below:
-
Set Port – Set the port that was setup in step 5.
-
Activate Widget – In the Equinox View, select the climate widget and select which zones are valid per profile.
-
Program the Controller– Press F5 so the controller accepts all the changes applied.
COOLMASTER UNIVERSAL VRF BRIDGE
The CoolMaster product line offers the ability to integrate, control and
manage any VRF or VRV HVAC system through a single device. The devices are
Plug & Play and do not require prior technical HVAC knowledge. Simply unbox,
ensure it is configured to the right HVAC brand using the built-in display,
connect as indicated, and done.
The product line includes 2 type of devices: CoolMaster and CoolMasterPro.
CoolMaster fits most residential and small-medium commercial settings where
the number of indoor units is limited, whereas CoolMasterPro addresses the
needs of the mid-to-large commercial market, and comes with comprehensive
integration capabilities for very large VRF/VRV installations or sites with
numerous indoor or sensor units and more advanced building monitoring,
management, service or control requirements.
NOTE: CoolMaster and CoolMasterPro replaced the CoolMasterNet product with its current licensing model.
COOLMASTER HARDWARE FEATURES
- Seamless integration of multiple types of HVAC systems with Vantage .
- Interfaces via RS232 (ASCII), RS485 (MODBUS RTU, BACNET MSTP), Ethernet (ASCII, MODBUS IP, BACNET IP) for all HVAC brands
- Simultaneous multi-brand HVAC support (optional)
- Touch screen display, for system management and control
- Configurable I/O’s (optional)
- Control & monitoring of HVAC indoor units operation
- Control.CoolRemote.net — Remote access from Smartphone, Tablet and PC platforms
- HVAC systems diagnostics (optional)
- Direct KNX connection (optional)
- Cloud integration by API (optional)
COOLMASTER SPECIFICATIONS
DESCRIPTION | SPECIFICATION |
---|---|
Hardware Dimensions | 90mm x 156mm x 35mm (3.54” x 6.14” x 1.33”) |
Weight | 266g (0.58lbs) |
Communication Protocol | TCP/IP Recommended or Serial |
HVAC Connection Line | Two screw terminals |
Power Supply | AC Power supply adapter 100V – 240V 50/60Hz to 12V |
LCD Display Information |
- On / Off Control
- Auto, Cool, Heat, Fan, Dry mode selection Set Temperature Control, Fan Speed Control Swing Control, Filter Reset Sign Group Operations
HVAC Manufacturer Compatibility List*|
- Daikin (DK)
- Mitsubishi Electric (ME), Mitsubishi Heavy (MH) Samsung (SM)
- LG (LG)
- Trane (TR)
- Carrier Midea (MD), Midea (MD) Toshiba (TO)
- Carrier Toshiba Fujitsu (FJ) Gree (GR) Hitachi (HT) Panasonic (PN) Haier (HA) Chigo (CG) Rheem (RH)
*Visit the CoolAutomation Support Center for the latest list of Compatible HVAC systems in your market: https://support.coolautomation.com/hc/en-us/sections/5009071299101-Compatibility
COOLERMASTER HARDWARE DIAGRAM
- USB Type A (Host)
- Power (Direct 12V-24V DC)
- Power Plug (100V-240V AC)
- RS232 Port
- L1 — HVAC Line 1
- L2 — HVAC Line 2
- L3 — RS485
- Ethernet Port
- GPIOs
- L7 — HVAC Line 7
- L6 — HVAC Line 6
- L5 — HVAC Line 5
- L4 — HVAC Line 4
- USB Mini (Device Port)
- DIP Switches P, Q, R, S
- LCD Touch Screen
COOLMASTER TOUCHSCREEN DETAILS
After successful installation, the LCD screen will show all the detected
indoor units and their statuses
SCREEN #1: MAIN LIST OF INDOOR UNITS
- Active HVAC Line (example: DK 22/21) (Groups/Units)
- Inactive HVAC Line
- All ON/OFF Operation Button
- Scrollbar
- Connected indoor unit with zone number (L1.101) and Set-Point temperature indication (Ex: 21 Celsius).
- Indoor Unit Operation Button (ON/OFF)
- Settings Menu Button
- CoolMaster Device MAC address
- CoolMaster Device IP address
- CoolMaster Cloud Connectivity Status
SCREEN #2: CONTROL OF INDOOR UNIT
- Active HVAC Line (Ex: DK 22/21) Groups/Units
- Inactive HVAC Lines
- Turn unit ON/OFF Operation Button
- Indoor Unit (IDU) address
- Fan Speed Control Button
- HVAC Unit Mode Control Button
- Settings Menu Button
- CoolMaster Device MAC Address
- CoolMaster Device IP Address
- CoolMaster Cloud Connectivity Status
COOLINKHUB – SMALL AND MID-CAPACITY SPLIT SYSTEMS
The Wired and Wireless Interface Adapter is used for integration of Multi-
Split and Split HVAC Systems. CoolPlug and CooLinkHub are CoolAutomation’s
solution to help you remotely access and control indoor VRF, indoor VRV,
Multi-split and mini-split air conditioning systems. This solution enables
simple integration with the Vantage Control System, as shown below.
SPLIT WIRED SYSTEM DIAGRAM
SPLIT WIRELESS SYSTEM DIAGRAM
COOLINKHUB PRODUCT OVERVIEW
Wired and Wireless Interface Adapter for the integration of Multi-Split and
Split HVAC Systems. CoolPlug and CooLinkHub are CoolAutomation’s solution to
help you remotely access and control indoor VRF, indoor VRV, Multi-split and
mini-split air conditioning systems. The solution enables simple integration
with the Vantage Control System.
The solution supports HVAC professionals striving to deliver a great customer
experience and Home Automation integrators needing to save time on complex
HVAC integration.
- Mini USB Device Connector
- RS232, 1/O Connector
- HVAC L2, Modbus Connector
- Power / Position of KNX option
- Ethernet Connector
- LCD Screen
COOLINKHUB SPECIFICATIONS
DESCRIPTION | SPECIFICATION |
---|---|
Hardware Dimensions, HWD | 2.56” x 4.64” x 1.25” (65mm x 118mm x 32mm) |
Weight | 0.26 lb (0.12 kg) |
Surrounding Temperature Limits | 14°F – 140°F (-10°C – 60°C) |
Operating Humidity | 0 – 96% |
Maximum PBU Wiring Length | 3280 ft (1000 m) |
Maximum RS232 Wiring Length | 82 ft (25 m) |
Maximum Ethernet Cable Length | 450 ft (137 m) |
CoolPlug – Wired Communication | PBUS Interface 2 wire, shielded, polarized, |
twisted pair 20-24 AWG
CoolPlug – Wireless Communication| 2.4 GHz, Spread spectrum 802.15.4, Wireless
mesh
Maximum Connected CoolPlug Units| 10
Wireless Range| 65 ft (20 m)
RS232 Communication| ASCII Interface
Power Supply| External power supply, 9-24 VDC
Power Consumption| 1 Watt
COOLINKHUB LCD SCREENS
CooLinkHub is equipped with an alphanumeric 8×2 characters LCD that presents
most of the important device parametric and status information.
- ETH Network Connection Status: Disconnected, Connected
- CoolRemote Cloud Connection Status: Not Connected, Connected, Communication in progress
- HVAC Line Communication Status: RX, TX
- Every one minute IP address (if acquired) and S/N are displayed
- Indoor Unit UID (L2.001 shown)
- Indoor Unit Status: ON, OFF
- Set Temperature
- Fan Speed: High, Medium, Low, Auto
- Operation Mode: CL-Cool, HT – Heat, FA – Fan, DR – Dry, AU – Auto
COOLPLUG PRODUCT OVERVIEW
CoolPlug is a plug & play device. The integration and installation process is
simple and can be synced with CooLinkHub via a wired or wireless connection.
CoolPlug’s wireless capabilities are ideal for retro-fit projects, as it
eliminates the need for drilling or opening up walls and ceilings. Contact
CoolAutomation to confirm compatibility with your HVAC indoor unit and to
obtain the right model CoolPlug for it.
CoolPlug and CooLinkHub work together to create a universal communication
channel which enables split HVAC indoor units to work with Vantage Control
systems.
CoolPlug and CooLinkHub provide automation integrators local and remote access
to control, monitor, and manage compatible Split,
Multi-Split, or Mini-Split HVAC systems through the creation of a bi-
directional and universal communication channel between the HVAC and
automation systems.
- PBUS Connector
- *S21 Connector
- Connector
*NOTE: In this example, the S21 Connector is for Daikin. Your version of CoolPlug might have a different connector, depending on different brands of HVAC you are connecting to.
COOLPLUG SPECIFICATIONS
DESCRIPTION | SPECIFICATION |
---|---|
Hardware Dimensions, HWD | 2.44” x 2.44” x 1.22” (62mm x 62mm x 31mm) |
Weight | 0.26 (0.12kg) |
Surrounding Temperature Limits | 14°F – 140°F (-10°C – 60°C) |
Operating Humidity | 0 – 96% |
Maximum PBVS Wiring Length | 3280 ft (1000m) |
CooLinkHub Communication | PBUS Interface 2 wire, shielded, polarized, twisted |
pair 20-24 AWG
Wireless Communication (Wireless Model Only)| 2.4 GHz, Spread spectrum
802.15.4, Wireless mesh
Wireless Range| 65 ft (20m)
Indoor HVAC Connectivity| 2 Wire, non-polar, 20-24 AWG
3 Wire, polar, 20-24 AWG
(Based on the specific indoor unit terminal connections)
Power Supply| 8-20 VDC, From indoor unit
Power Consumption| 0.4 Watt
COOLPLUG MODELS
CoolPlug models are HVAC manufacturer specific. Each CoolPlug has a small
round sticker with letters on the back (DK, DKS, etc.) indicating the HVAC
manufacturer that the CoolPlug is compatible with.
https://support.coolautomation.com/hc/en-us/articles/4612206118813-CoolPlug-
Models
COOLPLUG MODEL / STICKER| HVAC VENDOR| CABLE INCLUDED|
TERMINALS
---|---|---|---
HVAC – [DK]| Daikin| S21, S21 Narrow| S21, P1 P2, S403
HVAC – [DKS]| Daikin SIesta Series| Siesta|
HVAC – [SA] [TO] [PN]| Sanyo I Toshiba I Panasonic| | A B, R1 R2
HVAC – [PN] [CAPRA]| Panasonic Capra| CAPRA| CN-CNT
HVAC – [FJ]| Fujitsu / General| FJ003| 2 Wires, 3 Wires
HVAC – [ME]| Misubishi Electric| CN105| CN105, 1 2
HVAC – [MH]| Mitsubishi Heavy| | 2 Wires Only
HVAC – [HT]| Hitachi| | VRF Only
HVAC – [MD]| Midea| | X Y E
HVAC – [LG]| LG| LG Split Cable|
HVAC – [GR]| Gree| | GMV5 VRF Only
HVAC – [GRTS]| Gree| 4 Wire x 4| 4 Wires, 2 Wires
HVAC – [SM]| Samsung| | 4 Wires, 2 Wires
WIRED PBUS – DAISY CHAIN DIAGRAM
PBUS Cable : 2 Wire, shielded, twisted pair 20-24 AWG
HVAC CONNECTION: WIRELESS TO WIRELESS COOLPLUG-COOLINKHUB NETWORK
- WRLS Cool Plugs and WRLS CooLinkHub communicate with each other using CoolAutomation’s 2.4 GHz proprietary and secured mesh network. Each WRLS CooLinkHub creates a network and automatically connects to all paired devices within this network (WRLS CoolPlugs). Pairing of the WRLS CoolPlugs with the specific WRLS CooLinkHub can be factory pre-set (prior to shipment) or configured locally. Up to 10 CoolPlug devices can be connected to a single CooLinkHub.
- The recommended distance between each of the two devices (CoolPlug / CooLinkHub) is up to 20m (50 ft) line of sight. Please note that concrete walls, ceilings, and other types of obstacles or noise caused from electro-magnetic fields (generated by power cables or other sources), can significantly impact signal strength and will result in reduced distance.
- The network topology is a mesh type network, meaning that each device acts as receiver and a transmitter, and repeats the signal. For planning purposes, make sure you have connectivity between each of the two devices (CoolPlug with its neighbor CoolPlug, or CoolPlug with the CooLinkHub).
WIRING DIAGRAM: WIRELESS INTERFACE 2.4GHZ (MESH)
VIDEO: HOW TO PAIR COOLPLUG WIRELESS WITH COOLINKHUB
https://www.youtube.com/watch?v=AtL1hdMHkOU
COOLINK BRIDGE – AUXILIARY AND COMPLEMENTARY CLIMATE SYSTEMS
The CooLinkBridge is an Interface Adapter for the integration of
conventional and complimentary climate systems, such as Underfloor Heat
systems, conventional On/Off, and 24V control systems.
UNDERFLOOR HEAT SYSTEMS DIAGRAM
COOLINKBRIDGE PRODUCT OVERVIEW
- Auxiliary HVAC systems such as HVAC Zone Control Units, Heat Pumps and Underfloor Heating systems have their own communication protocol and interfaces, which can be complex to integrate into most home and building automation systems, smart home device, or cloud-based control applications. CoolAutomation’s offering includes a variety of controllers for non-VRF HVAC systems, such as heat pumps, fan coils, rooftop and packaged units, chillers, on/off controllers and analog & digital external sensors.
- CooLinkBridge opens a seamless and universal communication channel for CoolAutomation-approved 3rd party 24V conventional thermostats, Underfloor Heating controllers, Heat Pumps, Fan coils, rooftops and packaged units, on/off controllers and analog and digital external sensors to connect and communicate with the Vantage Control system. Contact CoolAutomation for more information on these parts.
- Underfloor Heating: Allows control of hydronic and electric underfloor heating zones.
24V Control: Allows control of fan coils, heat pumps, rooftop and packaged units via a connection to a 24V control smart touchscreen controller.
- Mini USB Device Connector
- RS232, 1/O Connector
- HVAC L2, Modbus Connector
- Power / Position of KNX option
- Ethernet Connector
- LCD Screen
COOLINKBRIDGE SPECIFICATIONS
DESCRIPTION | SPECIFICATION |
---|---|
Hardware Dimensions, HWD | 2.56” x 4.50” x 1.22” (65mm 115mm x 31mm) |
Weight | 266g (0.58lbs) |
Ambient Operating Temperature | 14°F – 140° F (-10°C – 60°C) |
Operating Humidity | 0 – 96% non-condensing |
Ambient Storage Temperature | -4°F – 158° F (-20°C – 70°C) |
Storage Humidity | 0 – 96% non-condensing |
LCD Size | 2 x 8 |
LCD Color | Grey |
LCD Interface | HD44780 |
Direct HVAC Connection | Connection to HVAC indoor unit |
MODBUS (A / B) | RS-485 Communication line |
Ethernet | 100 Mbps |
RS-232 | 9600Bps, ASCII |
USB Device | 12 Mbps |
Maximum Allowable Wiring Length To BMS Over RS232 | 82 ft (25m) |
Maximum Allowable Wiring Length To BMS Over RS-485 | 3,300 ft (1000 m) |
Maximum Allowable wiring Length T0 Router Over Ethernet | 450 ft (137 m) |
Power Supply Min Load | 5V60mA (via mini USB); 12V/35mA; 24V/20mA |
Power Supply Max Load | 5V/100mA (via mini USB); 12V/70mA; 24V/40mA |
COOLINKBRIDGE LCD SCREEN
The CooLinkBridge is equipped with an alphanumeric 8×2 characters LCD that
presents important device parameters and status information.
- ETH Network Connection Status: Disconnected, Connected
- CoolRemote Cloud Connection Status: Not Connected, Connected, Communication in progress
- HVAC Line Communication Status: RX, TX
- IP Address (if acquired) and S/N Display (1 min toggle)
- Indoor Unit UID (L2.001 shown)
- Indoor Unit Status: ON, OFF
- Set Temperature
- Fan Speed: High, Medium, Low, Auto
- Operation Mode: CL – Cool, HT – Heat, FA – Fan, DR – Dry, AU – Auto
UNDERFLOOR HEATING CONTROLS WITH VRF DIAGRAM
IMPORTANT NOTES AND RECOMMENDATIONS
-
By default, 1 line and 1 zone is created automatically. If needed, add additional zones and lines to the driver.
-
Each zone represents one HVAC indoor unit.
-
The zone numbers (UIDs) can be found on the LCD screen of the CoolAutomation Device.
-
The CoolAutomation device allows you to group multiple A/C indoor units together for easier control of common areas.
- You can add grouped units to a single zone by adding the main zone and clicking on the “GROUPED ZONES +” icon.
- For each unit added, set the indoor unit’s number. Group zones will follow the main zone, so no separate command need to be sent.
WARNING: If you have a group where you forgot to set the zone number (0-999), then no groups will be used for that main zone.
-
A full program is required after changing the address or other properties.
-
It is possible to display temperature from the Vantage FLUSHSENSOR on the widget instead of using the built-in A/C sensor readings from the CoolAutomation device.
NOTE : This is merely for display purposes, the HVAC unit cannot use this temperature for control actions.
FREQUENTLY ASKED QUESTIONS
-
How does CoolPlug communicate with a Vantage InFusion system?
The CoolPlug interface communicates with a Vantage InFusion system via one of the network gateway devices:- CooLinkHub – This is the most common setup. The CoolPlug can communicate with the CooLinkHub via either a wireless (mesh) or a hard-wired network. You can connect up to 10 CoolPlugs to a CooLinkHub
- CoolMaster – The CoolPlug can communicate with a CoolMaster via a hard-wired network. You can connect up to 32 CoolPlugs to a CoolMaster (and up to 255 to a CoolMasterPro).
-
How do I know if the CoolAutomation device is installed correctly?
The best way to test out successful installation and communication between the CoolAutomation device and the HVAC system is via the CoolAutomation iocControl App – which is free and included with all CoolAutomation devices. From there you can test out and confirm proper HVAC control with On/Off commands, set point changes, mode changes, and more. -
Do I need to have external Cloud/Internet connection enabled for my CoolAutomation controller?
No, all CoolAutomation devices operate as offline HVAC communication gateways for full control and integration, with no need for external communications. The integration with Vantage systems and all control commands and communication resides local at the Local Area Network level. However, connecting the CoolAutomation devices to the CoolAutomation Cloud allows for easier remote support and remote service capabilities. -
Why does my CoolMaster/CooLinkHub/CooLinkBridge not communicate properly with my Vantage system or terminal application?
The two keys to establishing communication are:
1. Knowing the IP address assigned to the CoolAutomation device,
2. Knowing the port number that the CoolAutomation device uses to communicate to other devices on the network
The IP address that is assigned to the interface, from the DHCP server, will show in the lower right corner of the CoolMaster screen and the upper left corner of the CooLinkHub or CooLinkBridge screen. The IP address of CooLinkHub and CooLinkBridge is shown for a few seconds every one minute. Once you know the IP address, be sure to use port number 10102. Communication to the CoolAutomation device can be tested using a terminal program (e.g., PuTTY) using Raw TCP – or it can be tested using the CoolAutomation Setup Utility.
- What is the iocControl App >
iocControl is CoolAutomation’s free App for quick and simple HVAC Control from any mobile device and/or Desktop computer. It allows for simple and advanced remote control, schedule, real-time status and malfunction error codes of your HVAC system(s). Simply install the app and register your CoolAutomation device(s) and you are ready to go.
More information here: https://coolautomation.com/products/controlapp/
SUPPORT
For questions or issues related to Vantage products, please contact Vantage Technical Support
- Phone : 1(800)555-9891, Option 1 then Option 3
- Email : vantagetech@legrand.com
- Hours : Mon – Fri, 9AM – 7PM EST
For questions or issues related to CoolAutomation products, please contact CoolAutomation Technical Support:
- Phone: 1(206)360-5769 (Call or Text)
- Online: https://support.coolautomation.com/hc/en-us/requests/new
- Hours: Mon – Fri, 8AM – 6PM EST
No. 050054 – rev. 1 8/23