CLAYPAKY CL3022 Tambora Batten Square Instruction Manual
- June 1, 2024
- CLAYPAKY
Table of Contents
CLAYPAKY CL3022 Tambora Batten Square
Product Information
Specifications
- Product Name: Tambora Batten
- Model: Round CL3010 / Square CL3022
- Power Supply: 200-240Vac / 100-120Vac
- Control Signal: DMX / Art-Net
- Power Connection: Neutrik PowerCON TRUE1 (IN/OUT)
- DMX Connection: 5-pin DMX IN/THRU
- Display: LCD Display
Product Usage Instructions
Safety Information
It is important to carefully read and keep the safety information provided
with the product. For digital access to safety information, visit the official
website at www.claypaky.com.
Unpacking and Preparation
When unpacking the product, ensure all contents are present as shown in the
packing contents diagram. Prepare the product for installation according to
the instructions provided.
Installation and Start-Up
-
Fixture Overview
The fixture includes functional buttons, an LCD display, power connections, DMX connections, and safety features. Familiarize yourself with these components before installation. -
Installing the Fixture
Install the fixture on the floor, truss, ceiling, or wall using appropriate mounting methods. Ensure to use the safety chain when required for overhead installations. -
Connecting to Mains Supply
Connect the power cord as per the provided instructions. Note the maximum number of fixtures that can be connected in parallel based on the power supply voltage. -
Connecting the Control Signal Line: DMX / Art-Net
Connect the control signal line, either DMX or Art-Net, based on your setup requirements. Follow the wiring diagram for proper connections. -
Switching on the Fixture and Basic Setup
To switch on the fixture, follow the steps outlined in the manual. Pay attention to any warning messages or prompts displayed on the LCD during startup.
FAQ
-
Q: How many fixtures can be connected in parallel?
A: You can connect up to a maximum of 4 Tambora Batten fixtures at 200-240Vac or 2 fixtures at 100-120Vac in parallel at the same time. -
Q: Where can I find digital safety information for the product?
A: Digital safety information can be accessed on the official Claypaky website at www.claypaky.com.
TAMBORA BATTEN ROUND TAMBORA BATTEN SQUARE
INSTRUCTION MANUAL
Congratulations on choosing a Claypaky product!
We thank you for your custom.
Please note that this product, as all the others in the rich Claypaky range,
has been designed and made with total quality to ensure excellent performance
and best meet your expectations and requirements.
SAFETY INFORMATION
SAFETY INFORMATION
IMPORTANT: Claypaky recommends you carefully read and keep the safety
information on this product, also available in digital format at the following
link: www.claypaky.com
Ref: FIS021 – Safety Information Tambora Batten
UNPACKING AND PREPARATION
INSTALLATION AND START-UP
Fixture overview
Installing the fixture
The projector can be installed on the floor resting on specific rubber feet, on a truss, on the ceiling or wall.
WARNING: the safety chain must be installed except when the projector rests on the floor. (Code 105015/801 available upon request). This must be secured to the projector support structure and then hooked to the fastening point at the centre of the fixture.
Connecting to mains supply
Connecting the control signal line: DMX / Art-Net
Use a cable conforming to specifications EIA RS-485: 2-pole twisted, shielded, 120Ω characteristic impedance, 22-24 AWG, low capacity. Do not use microphone cable or other cable with characteristics differing from those specified. End connections must be made using XLR type 5-pin male/female connectors. A terminating plug must be inserted on the last projector with a resistance of 120 (minimum 1/4 W) between terminals 2 and 3. IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing must be connected to the shield braid and pin 1 of the connectors.
Switching on the fixture and basic SetUp
Switch-on the fixture. The projector starts resetting the effects. At the same time, the following information scrolls on the display:
On conclusion of resetting in case of absence of the dmx signal, Tilt move to
the “Home” position (Tilt 128 bit). The control panel (Fig. 7) has a display
and buttons for the complete programming and management of the projector menu.
The display can be in one of two conditions: rest status and setting status.
When it is in the rest status, the display shows the projector’s DMX address.
During menu setting status, after a wait time (about 30 seconds) without any
key having been pressed, the display automatically returns to rest status. It
should be noted than when this condition occurs, any possible value that has
been modified but not yet confirmed with the F key will be cancelled.
Reversal of the display – Fig. 8
To activate this function, press UP B DOWN C keys simultaneously while the display is in the rest mode. This status will be memorised and maintained even for the next time it will be switched on. To return to the initial state, repeat the operation all over again.
Setting the projector starting address
On each projector, the starting address must be set for the control signal
(addresses from 1 to 512).
The address can also be set with the projector switched off.
Functions of the buttons – Using the menu
USING THE MENU
- Press LEFT once – “Main Menu” appears on the display.
- Use the keys to select the menu to be used:
- Setup (Setup Menu): To set the setting options.
- Option (Option Menu): To set the operating options
- Informations (Informations Menu): To read the counters, software version and other information.
- Manual Control (Manual control Menu): To trigger the test and manual control functions.
- Test (Test Menu): To check the proper functionning of effects
- Advanced (Advanced Menu): Access to the “Advanced menu” is recommended for a trained technical personnel.
- Press to display the first item in the selected menu.
- Use the UP and DOWN C keys to select the MENU items.
Setting addresses and options with the projector disconnected
The projector’s DMX address, as well as other possible operating options, can
also be set when the appliance is disconnected from the electricity supply.
All that is needed is to press RIGHT to momentarily activate the display and
thus access the settings. Once the required operations have been carried out,
the display will switch off again after a wait time of 30 seconds.
MAINTENANCE
Fuses replacing
Each Tambora Batten has 1 fuse 10AT 250V, associated with the main power cord connection.
Periodical cleaning & Caution
CAUTION
-
To avoid damage to the internal parts of the fixture when the fixture is not working, is recommended to turn the head down before turning the fixture off, so that the front lenses of the fixture are invested as little as possible from the sun.
-
Set Zoom channel to 255-bit before turning off the projector to facilitate the packaging of the projector.
-
To ensure optimal operation and performance for a long time it is essential to periodically clean the parts subject to dust and grease deposits. The frequency with which the following operations are to be carried out depends on various factors, such as the amount of the effects and the quality of the working environment (air humidity, presence of dust, salinity, etc.).
It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations:- General cleaning of internal parts.
- Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Claypaky.
- General visual check of the internal components, cabling, mechanical parts, etc.
- Electrical, photometric and functional checks; eventual repairs.
Cleaning the lenses
Only use neutral soap and water to clean the lenses, then dry it carefully
with a soft, non-abrasive cloth. (WARNING: the use of alcohol or any other
detergent could damage the lenses).
Battery removal
This product contains a rechargeable battery. To preserve the environment, please dispose the battery at the end of its life according to the regulation in force.
DIMENSIONS
CAUSE AND SOLUTION OF PROBLEMS
www.claypaky.com – Service support & Helpdesk: https://e-assist.tech
References
Read User Manual Online (PDF format)