IMPORTANT INSTRUCTIONS FOR SAFE USE
WARNING BEFORE USING UV-C STERILON AIR FOR
THE FIRST TIME, READ THE USER MANUAL AND
FOLLOW THE INSTRUCTIONS.
FLOW DISINFECTION
UVC AIR luminaires use ultraviolet light, destroy the DNA or RNA of all
microorganisms that will be exposed and remove viruses, bacteria and fungi
from the air. Covered UVC light does not reach the outside of the lamp. Thanks
to stimulated circulation, the air passes through luminaire interior, where it
is exposed to the light and cleaned, and then pushed outside. UV-C STERILON
BASIC luminaires may work in the presence of people.
Exposure method:
-
Place the lamp in a disinfected room, if possible in a central place, to increase the eectiveness of disinfection. Remember that the disinfection ein a given place decreases as the distance from the lamp increases.
-
Do not cover the luminaire fan, do not place any objects on the luminaire. In order not to disturb circulation, leave an empty space and do not put any objects within 1m of the luminaire fan.
-
There may be people in the room. They can move freely and do not need protective clothing.
-
Do not open the luminaire covers during its operation.
Secure the luminaire against uncontrolled opening by other people. -
Do not use in rooms smaller than 1 m
-
The smell emitted by the UV-C STERILON BASIC is a technical fragrance. It can last for approximately ⁶⁰ hours of device use. This smell does not pose a threat to
the users of the device. -
A small amount of visible blue light – which is a reflected light, does not contain UV-C radiation and is safe for humans.
Disinfection efficiency
- Depending on the lamp power, the flow is:
- For the power 72 W – 160 m /h; 72 W ECO – 110 m /h
- For the power 144 W – 200 m /h; 144 W ECO – 110 m /h
The maximum volume (cubature) of the disinfected room:
- for luminaires with a power of 72 W – 75 m
- for luminaires with a power of 144 W – 120 m
Maintenance and filter replacement
Sterilon Flow UVC BASIC luminaires are standard equipped with PPI30 filters
located in the fan housing. This filter should be checked after 4 months of the
device operation. In case of dirt that could block the air flow (e.g. when the
device is operated in dusty rooms), the filter should be replaced or cleaned
under running water after every 4 months of operation. If the filter is not
dirty during the first inspection, its cleanliness should be checked after
every 6 months (or 1000 hours) of operation of the device and replaced or
cleaned under running water if dirt appears. The filter should be removed from
the pressed-in (clicked-in) housing on the fan, replaced and the housing
pressed back in. The UV-C Sterilon luminaire is HEPA filter compatible. HEPA
filters can be installed interchangeably with dust filters.
Operational safety
Direct UV-C light is highly harmful to humans and other living organisms,
damages eyesight, skin and cell DNA. UV-C light degrades the DNA and RNA code
in the cells of living organisms. If housing was breached, no people or
animals should be within the range of direct UVC rays. Damage to the luminaire
will not affect your health while maintaining basic precautions. The luminaire
should be turned off immediately. If the fluorescent lamps break, ventilate the
room for 30 minutes and remove the contaminated parts, preferably with gloves.
Place them in a sealed plastic bag and take to a local waste disposal facility
for recycling. Do not Technical Data:
2x PL-L 36W, 220-240V, 50-60Hz (72W)
4x PL-L 36W, 220-240V, 50-60Hz (144W)
Cable 3m, 3×0,75mm
Protection class I
With UNI-SCHUCKO / UK plug
No protection against explosion. The light source used in this luminaire
should only be replaced by the manufacturer or his maintenance representative,
or a similarly qualified person.
If the external flexible cable is damaged it should be replaced with a special
cable available at the manufacturer or its after-sales service.
We would like to inform you that our product’s are marked in accordance with
the European Directive 2002/96/CE and Polish Act o n used electric and
electronic equipment with a sign of a crossed-out waste container. This mark
informs abort the fact that the device, after its application use, cannot be
placed together with other types of household waste. The user is obliged to
return it to the entities conducting a collection of used electric and
electronic equipment. The collection points, including local collection
points, shops and municipal entities create a proper system making it possible
for the return of the equipment. Proper proceeding with used electric and
electronic equipment contributes to the avoidance of damaging consequences for
the health of the inhabitants and natural environment chick result form the
presence of dangerous substances and improper storage and processing of such
devices and equipment.
Data aktualizacji/Date of update: 27.07.2022
LENA LIGHTING S.A.
ul.Kornicka 52, 63-000 Sroda Wlkp.
POLAND
tel. +48 61 28 60 300
e-mail: office@lenalighting.pl
www.lenalighting.pl
UV-C STERILON BASIC 72W / 144W – INSTALLATION INSTRUCTION
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>