LITHONIA LIGHTING 2024 AFB Emergency Light – Basics Outdoor LED Emergency Light Instruction Manual

June 1, 2024
LITHONIA LIGHTING

LITHONIA-LIGHTING-LOGO

LITHONIA LIGHTING 2024 AFB Emergency Light – Basics Outdoor LED Emergency

Light

LITHONIA-LIGHTING-2024-AFB-Emergency-Light -Basics-Outdoor-LED-Emergency-
Light-PRODUCT

Product Information

Specifications

  • Product Name: AFB OELR LED Remote Light
  • Power Supply: 5-30V DC
  • Mounting Height: Maximum 11.3 feet from ground
  • Junction Box Compatibility: 4 OCTAGON or 4 SQUARE junction box

Product Usage Instructions

Installation and Wiring

When installing the AFB OELR LED Remote Light, make sure to provide each unit with a 5-30V DC power supply for normal lighting. It is crucial not to exceed the rated input voltage to prevent product damage. To meet the minimum illumination requirements of NFPA 101, ensure that the maximum mounting height from the ground does not exceed 11.3 feet. Mount the unit through a pair of preformed keyholes onto a 4 OCTAGON junction box or through a pair of keyhole knockouts onto a 4 SQUARE junction box. Alternatively, you can use conduit entry for installation.

Maintenance

Regular maintenance of the AFB OELR LED Remote Light is essential to ensure optimal performance and longevity. Follow these guidelines:

  • Inspect the unit periodically for any signs of damage or wear.
  • Clean the light fixture gently using a soft, damp cloth to remove dust and debris.
  • Check the wiring connections to ensure they are secure and functioning properly.
  • If you notice any issues, contact the manufacturer or a qualified professional for assistance.

Wiring Diagram

Refer to the provided wiring diagram on Page 5 of the manual for detailed instructions on how to correctly wire the AFB OELR LED Remote Light.

FAQ

  • Q: What should I do if I exceed the rated input voltage during installation?
    • A: Exceeding the rated input voltage can cause product damage. If this occurs, immediately disconnect the power supply and contact the manufacturer for further guidance on resolving the issue.
  • Q: Can I mount the unit at a height greater than 11.3 feet?
    • A: It is not recommended to mount the AFB OELR LED Remote Light at a height greater than 11.3 feet from the ground to ensure compliance with NFPA 101 requirements and optimal performance.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc

WARNING RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
    • Verify that supply voltage is correct by comparing it with the luminaire label
    information.
    • Make all electrical and grounded connections in accordance with the
    National Electrical Code (NEC) and any applicable local code requirements.
    • All wiring connections should be capped with UL approved recognized wire
    connectors.

CAUTION RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

WARNING RISK OF BURN

  • Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

CAUTION RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
  • Unless individual product specifications deem otherwise: Never connect an LED product to dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
  • Only use fixture in its intended location.
  • LED products are polarity-sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
  • Do not touch individual electrical components, as this can cause ESD, shorten lamp life, or alter performance.
  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
  • Always read the complete installation instructions for the fixture prior to installation for any additional fixture specific warnings.
  • Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

ABL LED General Warnings, Form No. 503.203 © 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  • WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS ANDWARNINGSMAY RESULT IN DEATH, SERIOUS INJURY OR
  • SIGNIFICANT PROPERTY DAMAGE – For your protection, read and follow these warnings and instructions carefully before installing or maintaining this equipment. These instructions do not attempt to cover all installation and maintenance situations. If you do not understand these instructions or additional information is required, contact Lithonia Lighting or your local Lithonia Lighting distributor.
  • WARNING: RISK OF ELECTRIC SHOCK – NEVER CONNECT TO, DISCONNECT FROM OR SERVICE WHILE EQUIPMENT IS ENERGIZED.
  • WARNING: DO NOT USE aggressive MATERIALS OR SOLVENTS. USE OF THESE SUBSTANCESMAY DAMAGE FIXTURE,WHICH MAY RESULT IN PERSONAL INJURY.
  • WARNING: RISK OF Personal INJURY – This product may have sharp edges. Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing and maintaining this product. !
  • WARNING: Do not exceed fixtures ambient temperature -40°F-122°F (-40°C-50°C). Use of unauthorized input voltage voids warranty and UL listing of this product and may present a risk of fire or explosion.
    • All servicing should be performed by qualified personnel.
    • Consult your local building code for approved wiring and installation.
    • For use Outdoors. Failure to ensure conduit connections are properly protected against water ingress during installation may void warranty.
    • Do not mount near gas or electric heater.
    • Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
    • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
    • Do not use this equipment for other than intended use

INSTALLATION and WIRING

  • IMPORTANT: Provide each unit with a 5-30V DC power supply for normal lighting.
  • PRODUCT DAMAGE WILL OCCUR IF THE RATED INPUT VOLTAGE IS EXCEEDED.
  • NOTE: To meet the minimum illumination requirements of NFPA 101 (current Life Safety Code), the maximum mounting height from ground is 11.3 feet
  • NOTE: This unit should be mounted ONLY through a pair of the preformed keyholes onto a 4” “OCTAGON” junction box, or through a pair of the keyhole knockouts onto a 4” “SQUARE” junction box, or using conduit entry.

OPENING THE UNIT

Use a flat head screw driver, locate the slots, one on each side and two on top, and twist screw driver in each slotLITHONIA-LIGHTING-2024-AFB-
Emergency-Light -Basics-Outdoor-LED-Emergency-Light-FIG
\(1\)

JUNCTION BOX MOUNTING
  1. Feed the supply leads through the junction box and prepare the lead ends to make connections to the fixture leads.
  2. On the rear housing, remove the round center knockout (1.2” diameter) and the desired pair of keyhole knockouts. Use knockouts instead of drilling holes to prevent metal shavings from entering the unit.LITHONIA-LIGHTING-2024-AFB-Emergency-Light -Basics-Outdoor-LED-Emergency-Light-FIG \(3\)
  3. Route the supply leads through the knockout and attach them to the respective leads on the fixture. Grounding is not required for remote units.
  4. Mount the rear housing on the junction box with suitable hardware (not supplied).
SURFACE CONDUIT MOUNTING

NOTE: to avoid interference with components in the housing, use the most compact wire connectors appropriate to the wire gauge.

  1. PREPARING THE UNIT FOR CONDUIT :
    Remove the conduit plug from inside. The unit is threaded to accept 1/2” NPT threads (14 TPI), which are common in rigid conduit and EMT connector products. Rigid conduit or EMT fittings can be directly threaded into the housing without the need for a locknut, or for wet locations, use an approved wet location fittingLITHONIA-LIGHTING-2024-AFB-Emergency-Light -Basics-
Outdoor-LED-Emergency-Light-FIG \(4\)

  2. BRANCH CIRCUITWIRING :
    The wiring compartment is sized for (3) incoming 12 AWG wires and (3) outgoing 12 AWG wires and common wire connectors. If your branch circuit is a larger AWG or you have a need for a through-wire application, install the branch circuit raceway such that you do not have to pass the circuit through the fixture.

FINAL ASSEMBLY

  1. Ensure all wires and connectors are routed to  avoid interference with other components. Line up the alignment pins (located at diagonally opposite corners of the front housing) with the mating receptacles (two on the rear housing).
  2. To properly close the unit, it is important to push the cover straight onto the rear housing. If the pins are not aligned with the receptacles, the housing will not close properly. Make sure there are no gaps between the front and rear housings. If gap is present, open the unit and reinstall the front housing.

MAINTENANCE

LIGHT ENGINE REPLACEMENT

  1. Open the unit and disconnect all connectors from the charger board, remove the screws from the plastic cover and charger board and take them out
  2. Remove mounting screws from the bracket and remove the light engine assembly. Carefully unplug connectors from the light engine and reconnect the connectors to the new light engine. Reinstall light engine assembly and ensure that the lamp wires are not pinched.

CHARGER BOARD REPLACEMENT

  1. Disconnect input leads on the charger board. Remove plastic cover from the housing.
  2. Disconnect all connectors from the charger board
  3. Remove all the screws from the charger board, replace the charger board, connect the connectors in the same orientation to the new charger board.LITHONIA-LIGHTING-2024-AFB-Emergency-Light -Basics-Outdoor-LED-Emergency-Light-FIG \(10\)

WIRING DIAGRAM

Federal Communications Commission (FCC) requirements:

This device complies with FCC Title 47, Part 15, Subpart B. This device does not cause harmful interference

WIRING DIAGRAMLITHONIA-LIGHTING-2024-AFB-Emergency-Light -Basics-Outdoor-
LED-Emergency-Light-FIG \(11\)

LIFE SAFETY SOLUTIONS

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>