READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to con-firm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installa-tion, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Never connect an LED product to an unapproved dimmer pack. Contact ABL directly for any dimmers not specifically recommended for the product.
- Unless individual product specifications deem otherwise: Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Maximum ambient temperature is 90°C. Do not operate fixture at temperatures higher than this.
- Unless individual product specifications deem otherwise: Never mount in places where fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal ground-ing equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- There are no user serviceable parts inside the unit. Do not rewire, reconfigure, or modify the unit or attempt any repairs yourself. Additionally, field replacement of the LED assembly or lamps is not allowed by UL standards at this time. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative.
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with one of the following Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
This device complies with Part 18 of the FCC Rules but may cause interference
with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem move the device away from the luminaire or
plug into a dif-ferent outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications
equipment or other critical navigation or communications equipment operating
between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For
a com-plete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
OUR BRANDS
Indoor/Outdoor: Lithonia Lighting, Carandini, Holophane, RELOC Indoor
Lighting: Gotham, Mark Architectural Lighting, Peerless, Renaissance Lighting,
Winona Lighting Outdoor Lighting: American Electric Lighting, Antique Street
Lamps, Hydrel, Tersen Controls: DARK TO LIGHT, Lighting Control & Design,
ROAM, Sensor Switch, Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out
of improper or careless installation or handling of its products. ABL LED
General Warnings, Form No. 503.203 © 2010 Acuity Brands Lighting, Inc. All
rights reserved. 12/01/10
These installation instructions are used for installing the following
luminaires and kits
Luminaire Variant | Mounting Kits |
---|---|
LDN4 | Hangers bars (Included) |
LDN4 SQ | |
LDN6 | |
LDN6 SQ |
A) Identification of Downlight Luminaire Part
Important Safety Information – For Your Protection, Read Carefully
Warning: Risk of fire. Do not install insulation within 3 inches of
fixture sides or wiring compartment, nor above fixture in such a manner as to
entrap heat.
Electric current can cause painful shock or serious injury unless handled
properly. For your safety, always remember the following:
- Turn off the supply power.
- Ground the fixture to avoid potential electrical shocks.
- Do not handle an energized fixture or energize any fixture with wet hands, when standing on a wet or damp surface, or in water.
Lay-in Panel T-bar Ceiling Installation
Cut ceiling opening slightly larger than the outside diameter on the mounting
frame.
4” Ceiling opening: 5-1/8” (13cm).
6” Ceiling opening: 7-1/8” (18.1cm)| Cut ceiling opening slightly larger than
the outside diameter on the mounting frame.
LDN4SQ: 5-1/8 X 5 1/8” (13cm X 13cm)
LDN6SQ: 7-1/8” X 7-1/8” (18.1cm X 18.1cm)| Assemble the channel bars to each
side of the of the mounting frame with the included hardware. Leave the
hardware loose to adjust the position of the frame in the ceiling.
Adjust channel bars to the correct spacing between T-bar. See Page 5 for
procedure for non-accessible ceiling installation.| Secure channel bars to
T-bar by means of a fastener (wire ties, screws, etc.)| Alternate bar hangers
used for EL/ELR:
Attach the adjustable brackets to the fixture using the hardware provided.
Wing nuts should face inward for adjustment through the ceiling.
Place (2) hanger bars together so that the formed tabs engage the slots to
form one long rigid hanger bar. Aligning the ”V” cutouts in the hanger bar
will set the spacing for a 24” ceiling.| Locate the T-bar slots near the ends
of the bar hangers, bend the tabs out at 45 degree angle from the bar hanger
at each end. Snap the bar hangers over the ceiling T-bars for a secure fit.
Or the use of a fastener (wire tie, screw, etc.) is acceptable as well.|
Position mounting frame through opening in ceiling.
Adjust the mounting frame vertically to align the bottom edge of the draw-
down to either flush or slightly above the ceiling line.| Re-tighten both
vertical adjustment nuts.| Re-tighten both channel bar clamping screws.
Remove knockouts on junction box to feed power supply to fixture. Supply wire
must meet applicable electrical codes and be rated for a minimum of 90°C.
Junction box is thru-wire rated for 8-No. 12 AWG conductors (4in-4out).|
Complete necessary splices. Snap the door/driver assembly onto the junction
box.| Squeeze wire springs on the light engine and insert each leg of the
spring into the slots on the brackets on either side of the opening in the
mounting frame. Pull the light engine down so the looped end of the wire
spring rests on the top of the bracket.
Align the opening in the trim with the tabs on the light engine. Rotate the trim clockwise until trim slot aligns with the hole in the trim holder. Secure trim with provided screw. Push the light engine up so it flush with the ceiling.
D) Non-accessible Ceiling Installation (e.g. plaster, drywall, etc.)
Mount to ceiling structure with flanges on channel bars resting against the
bottom faces of the joists. Drive included nail into joist to secure. Move
vertical adjustment to lowest point. For WALLWASH applications, ensure the
junction box is oriented either directly toward or away from the washed
wall. Trim rotates only in 180.| Secure channel bars to Hatch Channel by means
of a fastener (wire ties, screws, etc.)| Alternate bar hangers used for
EL/ELR:
Attach the adjustable brackets to the fixture using the hardware provided.
Wing nuts should face inward for adjustment through the ceiling.
Place (2) hanger bars together so that the formed tabs engage the slots to
form one long rigid hanger bar. Aligning the ”V” cutouts in the hanger bar
will set the spacing for a 24” ceiling.| Bend (4) bar hangers per fixture at
right angles at the row of (3) holes 2 inches from one end of the bar hangers
to attach to ceiling joists.| Secure channel bars to Hat Channel by means of a
fastener (wire ties, screws, etc.)
E) Battery Pack Installation
Install battery pack across hanger bars engaging the battery tray slots onto the hanger bars. The battery tray is allowed to float to accommodate different installation ituations.
Lithonia Lighting
One Lithonia Way Conyers Georgia 30012
Phone: 800-705-SERV (7378)
www.Lithonia.com
CJ5201053 Rev H
© Acuity Brands Lighting, Inc. 2016