S S REGELTECHNIK V100 Temperature Measuring Transducers Calibratable Instruction Manual
- June 1, 2024
- S S REGELTECHNIK
Table of Contents
S S REGELTECHNIK V100 Temperature Measuring Transducers Calibratable
Product Information
Specifications:
- Power Supply: < 1.2 W / 24 V DC; < 1.8 VA / 24 V AC
- Sensor: Pt1000, DIN EN 60751, Class B
- Communication: W-Modbus (Wireless Modbus with 2.4 GHz ISM), Modbus (RTU-Mode), Address range 0…247 adjustable
- Data Points: 4 s / 32 s
- Dimensions: 108 x 78.5 x 43.3 mm (Without Display), 108 x 78.5 x 45.8 mm (With Display)
- Protection Rating: IP65
Feature | Specification |
---|---|
Power Supply | 24 V AC (±20 %) and 15…36 V DC |
Power Consumption | < 1,2 W / 24 V DC; < 1,8 VA / 24 V AC |
Units of Measurement | SI (default) or Imperial Units (configurable via Modbus) |
Data Points | Temperature (°C/°F) |
Sensor | Pt1000, DIN EN 60751, Class B |
Sensor Protection | Dependent on the device type |
Measuring Range | -50…+150 °C |
Temperature Deviation | Typical ±0.2K at +25°C |
Zero Point Offset | ±10 °C |
Ambient Temperature | -30…+70 °C |
Medium | Non-aggressive, non-combustible gases |
Cable Connection | Plastic cable gland M20 x 1.5 or M12 connector (optional) |
Permissible Humidity | < 95 % RH, non-condensing |
Protection Class | III according to EN 60 730 |
Protection Type | IP 65 according to EN 60 529 |
Optional Features | Display with backlight, three-line, programmable |
Self-Diagnostics | Error 1 for sensor break, Error 2 for sensor short-circuit |
Product Usage Instructions
Installation:
- Ensure the power supply matches the specifications mentioned.
- Mount the temperature measuring transducer in a suitable location.
- If using a cable connection, secure it with the provided cable gland or optional M12 connector.
Configuration:
- Set the desired address range on the device using the DIP switches.
- For wireless communication, pair the sensor by following the pairing instructions provided.
Operation:
- Monitor the displayed temperature readings on the device.
- Check for any error messages displayed on the screen.
FAQs
- Q: How do I troubleshoot communication issues with the sensor?
- A: If you encounter communication problems, first check the network integration setup to ensure proper configuration. Verify the address settings and consider re-pairing the sensor if needed.
- Q: Can I use the device without a display?
- A: Yes, the device can be used without a display. However, it is recommended to have a display for convenient monitoring of temperature readings and error messages.
Contact Information
For additional support or inquiries, contact S+S Regeltechnik at mail@SplusS.de or visit www.SplusS.de – Your sensor technology partner.
“`
References
Read User Manual Online (PDF format)
Loading......