KEMLAN Wall Penetration Series II Coupe Fireplace Instruction Manual

June 4, 2024
KEMLAN

KEMLAN-LOGOKEMLAN-LOGO

KEMLAN Wall Penetration Series II Coupe Fireplace

KEMLAN-Wall-Penetration-Series-II-Coupe-Fireplace-
PRODUCT

DIMENSIONS

TWO DOOR DOUBLE SIDED UNIT CENTRE FLUE SUIT BUILDING INTO MASONRY

KEMLAN-Wall-Penetration-Series-II-Coupe-Fireplace-
FIG-1

INSTALLATION INSTRUCTION

COUPE ( 2 DOOR ) WALL PENETRATION INSTALLATION

  1.  Locate desired position. Check that there are no trusses or beams in the ceiling to obstruct the flue on the free-standing side of the wall

  2.  Cut hole in the wall minimum. 1300mm wide and 1500mm high.
    NOTE: if the brickwork is taken to the ceiling a standard kit may be used. If any combustible wall is left above brickwork a treble kit must be used to prevent wall damage ( figure 2 ).

  3.  If the floor is wooden secure a 1200mm x 1200mm piece of A C sheet to the floor as per figure 1. this should protrude 370mm from centre line of wall flush side and 830mm from centre line on the free-standing side.

  4.  Lay bricks on A C sheet as per figure 1. This will give correct size hearths on both sides of the wall. If floor is cement then tiles or slate may be used instead of bricks.

  5.  Position combination surround/lintel on TOP of hearth and in a central position. Check levels.

  6.  Lay masonry as per figure 2. with normal bricks there will be approx. 45mm gap between end of brick & inside vertical face of surround. This may be filled with mortar ( figure 1). Adjust mortar so that 9th course finishes level with inside horizontal flat section of surround. Finish brickwork in normal way using surround as lintel ( figure 2).

  7.  After wall is completed slide fireplace into position. If you remove the doors during this operation it makes life easier. Ensure they are replaced on original sides.

  8.  Install flue kit as per figure 2.

KEMLAN-Wall-Penetration-Series-II-Coupe-Fireplace-
FIG-2

COUPE WALL PENETRATION MODEL

KEMLAN-Wall-Penetration-Series-II-Coupe-Fireplace-
FIG-3

Note: Minimum hebel / brick cut out is 660mm wide x 770mm highKEMLAN-
Wall-Penetration-Series-II-Coupe-Fireplace-FIG-4

COUPE WALL PENETRATION DOUBLE BRICK CONFIGURATION

KEMLAN-Wall-Penetration-Series-II-Coupe-Fireplace-
FIG-5

MINIMUM HEIGHT OF FLUE SYSTEM EXIT

KEMLAN-Wall-Penetration-Series-II-Coupe-Fireplace-
FIG-6

Documents / Resources

| KEMLAN Wall Penetration Series II Coupe Fireplace [pdf] Instruction Manual
Wall Penetration Series II Coupe Fireplace, Wall Penetration Series II, Coupe, Fireplace, Coupe Fireplace
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KEMLAN User Manuals

Related Manuals