Kemlan HALO 800 FS SOFTWOOD Freestanding Highland Fires And BBQs Instruction Manual
- June 1, 2024
- KEMLAN
Table of Contents
Kemlan HALO 800 FS SOFTWOOD Freestanding Highland Fires And BBQs
Product Information
Specifications :
- Model: HALO 800 FS SOFTWOOD
- Dimensions (mm):
- A: 493
- B: 595
- C: 588
- D: 866
- F: 215
- G: 598
- I: 433
- L: 603
- M: 302
Product Usage Instructions
Installation Guidelines:
1. Ensure the unit is placed with proper clearances as per the provided dimensions.
2. If installing with a rear flue shield, ensure the shield covers the rear of the spigot.
3. Follow Appendix F guidelines for installing heat shields and flue kits.
Freestanding Unit Setup:
1. Install the baffle plate and air tubes as per the provided instructions.
2. Make sure all air tube holes are pointing towards the sides and bottom of the appliance.
3. Position the baffle plates correctly on top of the air tubes.
FAQ:
- Q: What are the warranty details for the HALO 800 freestanding hardwood unit?
- A: The firebox is covered by a 10-year warranty, while other parts have a one-year limited warranty.
- Q: Can any flue kits be used with this fireplace?
- A: Yes, any Appendix F-approved flue kits can be used as long as they comply with laboratory-tested heat shielding requirements.
IMPORTANT:
INSTALLER, PLEASE LEAVE THESE INSTRUCTIONS WITH THE UNIT ON COMPLETION.
DIMENSIONS
HALO 800 FREESTANDING HARDWOOD WITH FAN
HALO 800 FREESTANDING HARDWOOD CLEARANCES
- Parallel position
Hearth Table
The rear wall clearance can be 150mm from a combustible wall when installed with an additional 900mm high x 180 deg. stainless steel rear flue shield.. The rear flue shield must cover the rear of the spigot. The back clearance will be 350mm if an additional flue heatshield is not fitted
Corner position
HALO 800 HARDWOOD FREESTANDING MERIDIAN BENCH MEASUREMENTS
FREESTANDING UNIT WITH HEAT SHIELD ( APPENDIX F)
IMPORTANT:
NEW FLUE KIT ACTIVE + HALF HEATSHIELD – “ANY SINGLE HEATSHIELD CAN BE USED FROM 900MM UP TO 1200MM HEIGHT” “THIS HEATER HAS BEEN TESTED WITH THE FAN CONNECTED TO A STANDARD3 PIN GPO SOCKET OUTLET. THE DOES NOT NEED TO BE HARD WIRED”.
IMPORTANT: ANY APPENDIX F-APPROVED FLUE KITS CAN BE USED ON THESE KEMLAN FREESTANDING FIREPLACES AS LONG AS IT COMPLY WITH THE LABORATORY-TESTED HEAT SHIELDING”
FREESTANDING FLUE KIT( APPENDIX F)
- 2 – 6” STAINLESS STEEL FLUE 1000mm CRIMPED
- 2 – 6” STAINLESS STEEL FLUE 1000mm CRIMPED, BLACK
- 2 – 8” GALVANISED FLUE 1000mm PLAIN
- 2 – 8” GALVANISED FLUE 1000mm CRIMPED
- 1 – 10” GALVANISED FLUE 1000mm PLAIN
- 1 – 10” DROP BOX, 6”-10” VENTED CAP, CRIMPED, BLACK
- 1 – 8” HEATSHIELD BLACK
- 2 – ANGLE BRACKETS GALVANISED
- 1200x50x50mm
- 1 – 10” ROUND CEILING TRIM, BLACK
- 1 – 10” RAKED CEILING TRIM
- 1 – 6” – 10” DOUBLE CONE COWL
- 1 – SPACING KIT
- 1 – INSTALLATION INSTRUCTION
FREESTANDING UNIT WITH HEAT SHIELD ( DECRO 8”)
FREESTANDING DECRO FLUE KIT
- 4 – 6” STAINLESS STEEL FLUE 1000mm CRIMPED
- 2 – 8” GALVANISED FLUE 1000mm PLAIN
- 1 – 10” GALVANISED FLUE 1000mm PLAIN
- 1 – 10” DROP BOX, 8”-10” VENTED CAP, CRIMPED, BLACK
- 1 – DECROSHIELD (A) 8” -900mm (WITH HEATSHIELD) BLACK
- 1 – DECROSHIELD (E) 8” -900mm (WITH HEATSHIELD)BLACK
- 2 – ANGLE BRACKETS GALVANISED
- 1200x50x50mm
- 1 – ADDITIONAL HEATSHIELD
- 1 – 10” ROUND CEILING TRIM, BLACK
- 1 – 10” RAKED CEILING TRIM
- 1 – 6” – 10” DOUBLE CONE COWL
- 1 – SPACING KIT
- 1 – INSTALLATION INSTRUCTION
HALO 800 HARDWOOD/SOFTWOOD BAFFLE PLATE / AIR TUBE INSTALLATION INSTRUCTION
- Install the first air tube by pushing it up, over, and into the air tube holders. Make sure the air tube end with no cap is installed towards the back.
- All air tube holes must point to the sides and bottom of the appliance. Push the air tube as far back as possible.
- Place baffle plate (1) on top of the air tube, 212mm left to right, 222mm front to back, and push baffle plates as far back as possible
- Position baffle plate (2) on top of baffle plate (1).
- Install air tube and baffle plate (3) as per figure (3), this time install the baffle plates opposite sides to the first one.
- The final step is to install the baffle plate (2) that has been placed on top of the baffle plate (1). Lower baffle plate (2) into the gap and push towards the back. The assembly is now complete.
INSTALLATION INSTRUCTIONS
MINIMUM HEIGHT OF FLUE SYSTEM EXIT
INSTALLATION TO COMPLY WITH AS/NZS 2918
Operating Instructions
Congratulations on the purchase of your Australian-made Kemlan slow-combustion
wood fireplace. We hope this serves you well, not just as a stunning feature;
but as a functional tool for heating your home and keeping you and your family
warm however cold the winters may get, because this is what Kemlan specialises
in and has perfected, making fires in Brisbane QLD since 1969, ‘Australian
made for Australian conditions’. Welcome to the Kemlan family.
I would like to share with you the correct way to operate your Kemlan wood
fire giving the best results for bothheating and useability.
Let’s get started:
The First Burns –
Unfortunately, we have no control over how the fire is loaded nor do we have any control over what quality of fuel/timber is used, therefore we can only give recommendations, and this will be the difference in heat output andlength of burn.
Softwood should always be used as the main fuel source in all Kemlan wood heaters at a moisture level of between 12% – 20% (always have a moisture meter).
If the timber is too dry it will burn faster, if the timber is too wet it will struggle to burn at all and give very little heat. The first few burns in a wood fire are commonly referred to as ‘curing burns’, this is when you are getting heat into the appliances’ steel and paint for the first time.
What we are trying to achieve here is 3-fold:
The first goal it to get heat into the white ceramic baffles and the steel
flue system, getting these 2 things hot will create the ‘draw’ of the
fireplace this is the process in which the smoke is drawn out of the fireplace
chamber through the flue system.
The second goal is to lay a bed of ash in the base of the fire, The ash in the
bottom of the fire is essential to the performance of the fireplace, the
optimal thickness of ash is 2-3 Inches (25mm – 75mm).
Having this bed of ash will assist the fuel to light easier creating an air
layer under the timber, it will also assist in a longer hotter burn as the ash
holds a large amount of the heat while the timber above is burning. So DO NOT
clean your ash out until you have to, you should never see the firebricks in
the base of your fire.
The third goal of the initial burns is to cure the paint on the fireplace
casing, Kemlan fires are painted with a high-temperature paint. When first
applied at our factory, the paint is very soft, we place all finished
fireplaces under
heat lamps to start the ‘curing’ process but because of the time it takes and
the temperature the casing needs to stay at to complete this process we need
YOU to finish this cure in
your home by lighting your new fire! So, let’s do it!……
Building your fire –
Whether you have purchased a small, medium or large chamber fireplace the set- up is the same. Kemlan introduces more primary air into the chamber of the fireplace than most other brands on the market, this makes it very easy to light the fire from a cold start, it also makes it easy for you the user of the fireplace to load the paper or firelighters, kindling (small pieces of softwood) and softwood into the chamber straight away.
Your goal should be to fill the fireplace chamber front to back, side to side to make sure heat is evenly distributed throughout the entire firebox. We don’t want to have to keep tending to the fireplace slowly adding pieces of timber and constantly opening the door, one full load of timber is far better.
Scan the QR code below to access the ‘How to stack and light your Kemlan wood fire’ video.
Please take some time to watch to see if your process is the same.
Now your Kemlan fire is up and running make sure to keep the primary air slide fully open, this will ensure maximum oxygen is getting to the fuel and this will create quicker heat into the fireplace box, baffle, flue, and of course your home.
The air slide can move from extreme left (fully open) to extreme right (fully closed). Think of this slide like an accelerator and brake on a car. Fully open would be putting your foot down on your car’s accelerator, fully closed is like putting the brakes on in the car. When we want energy into the room (KW) we want the slide open, As the room gets to the desired temperature the air slide can be moved towards the right-hand side reducing the air to the chamber and slowing the energy output and fuel consumption.
The air slide should only be moved half to ¾ of the way across while you can still tend to the fire, closing it completely or starving the fire should only be done when you cannot tend to the fire for long periods of time(e.g. going to bed) when your only goal is for the length of burn.
Remember no matter whether it is a curing burn or an everyday use, heat is key, never light a small fire! A small fire in a large, chambered firebox will not produce any heat in the components of the fireplace or in your room. Choose the fire that best suits your living and heating requirements.
Reloading your Kemlan fire –
When it is time to add timber to your fireplace firstly make sure the underside of your white baffles is actually white, if they are still black this will mean the softwood has not fully caught alight. If this is the case wait, you will notice as the fire heats up and your seasoned softwood is fully lit the baffle plates will return to the original white condition, this means the fire drawing correctly through the flue system and burning cleanly with the secondary air in full swing.
You can now open the air slide fully, crack the door slightly allowing the air pressure to equal then carefully fully open the door.
Have the timber you are going to load in the chamber ready to immediately reload, be prepared, don’t open the door and then go looking for the optimal pieces of timber, the longer you wait the colder the chamber will get and the higher the chance of smoke coming back into the room.
Overnight burns –
All medium and large-size Kemlan fireplaces have what is called an ‘overnight burn’ but what does this mean??
As we have touched on above, the air slide should only be shut down fully when you want an extended length of burn, as soon as you starve the firebox of air the fire will burn dirtier and heat output will be greatly reduced, in some instances the glass will blacken due to the lack of air movement inside the chamber. The black creosote will burn off the glass when the fire’s air control is back up to high with a new load of timber.
Generally, a Kemlan medium to large chamber will burn between 8 – 12 hours depending on the quality of fuel/timber and how full you stack the chamber. For maximum burn time, you would fill the chamber up to 50mm below the secondary air tubes underneath the white baffle plate. The larger the pieces of timber the better!
After the 8-12 hours you should still have glowing embers in the base of the fire, a small amount of kindling and medium size pieces of softwood can then be re-loaded making sure the air control has been moved back to ‘full left’ introducing maximum primary air again. If you follow these simple steps, you will find your Kemlan fireplace is one of the best investments you have made to your home. From everyone in Kemlan, we thank you for your business and wish you a lifetime of warmth and enjoyment.
IMPORTANT:
UNDER NO CIRCUMSTANCES SHOULD ANY SOLVENTS SUCH AS METHYLATED SPIRITS, PETROL, MINERAL TURPENTINE ETC OR DETERGENTS, BE ALLOWED TO COME IN CONTACT WITH THE PAINTED SURFACE OF THE HEATER AS DAMAGE TO THE FINISH WILL RESULT. IF AN ACCIDENT DOES OCCUR, SPRAY CAN PAINT IS AVAILABLE FROM YOUR NEAREST KEMLAN DEALER.
WARRANTY
- Kemlan wood heaters carry a warranty on the 6mm firebox for a period of ten (10) years.
- This warranty also covers other components of the heater for a period of one (1) year. These components include the baffle plate, handle assembly, secondary air tubes and fan.
- Kemlan’s warranty covers the wood heaters against defects in materials and manufacture.
THIS WARRANTY DOES NOT COVER –
- Failure to comply with manufacturer’s operation instructions.
- Normal wear and tear or damage caused by incorrect installation.
- Any form of rust and/or corrosion to the painted finish of the heater.
- Damage to the glass in the door, if the damage is caused by impact or misuse.
- The cost of collection and delivery of the wood heater and/or parts.
- Damage caused by water ingress.
- Cost of removal of the defective heater or re-installation of a replacement heater.
- Failure to use fireplace components supplied by Kemlan Industries Pty Ltd.
- Cost of inspection for damaged heater.
CLAIMS –
- (I) Kemlan will provide a full replacement of the heater in the first five years after installation.
- (ii) Replacement in the subsequent five years (i.e. sixth to tenth year after installation will be on the following basis.
- The owner will pay fifty percent of the current retail price if the claim is made in the sixth year – tenth year after purchase.
- Replacement of heater subject to all conditions in section four of warranty.
- Should any defects occur, contact the Kemlan distributor from whom you purchased the heater.
- Under this warranty, the defective parts will be repaired or replaced, free of charge.
- 6. The fireplace installation must comply with the relevant local statutes, ordinances, regulations, and bylaws
THIS WARRANTY IS VOID IF:
The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine or other damaging chemicals. Over-firing can be identified by, but not limited to, warped plated or tubes, rust-colored cast iron, bubbling, cracking, and discoloration of steel or enamel finishes.
PLEASE COMPLETE AND RETAIN THIS SECTION FOR YOUR RECORDS
Purchased from: ………………………………………………………………………………………….
Address: ……………………………………………………………………………………………………..
Date of Purchase: …
10-YEAR FIREBOX WARRANTY
The firebox is covered by a 10-year warranty.
Other parts are covered by a one-year limited warranty.
- Head Office – 13 French Avenue, Brendale, Queensland 4500
- Telephone – PH: (07) 3490 5500
- Facsimile – FAX: (07) 3490 5520
- Website: – www.jetmaster.com.au
- Business hours: – Monday to Thursday 7:30 am-4:00 pm. Friday 7:30 am-2:00 pm
- Email: – sales@jetmaster.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>