MEAN WELL SD-150 Series 150W Single Output DC-DC Converter Owner’s Manual
- June 1, 2024
- MEAN WELL
Table of Contents
MEAN WELL SD-150 Series 150W Single Output DC-DC Converter Owner’s Manual
Product Information
Specifications
- Input Range: 2:1 wide
- Protections: Short circuit, Overload, Over voltage
- Isolation: 1500VAC
- EMI Filter: Built-in
- Full Load Burn-in Test: 100%
- Input Voltage Design: 24V and 48V (LVD)
- Warranty: 2 years
- Standards: AS/NZS62368-1, BS EN/EN62368-1 (D type), TPTC004 IEC62368-1 (D type)
MODEL| SD-150B-12| SD-150C-12| SD-150D-12| SD-
150B-24| SD-150C-24| SD-150D-24
---|---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 24V
RATED CURRENT| 12.5A| 6.3A
CURRENT RANGE| 0 ~ 12.5A| 0 ~ 6.3A
RATED POWER| 150W| 151.2W
RIPPLE & NOISE (max.) **Note.2| 120mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 11 ~ 16VDC| 23 ~ 30VDC
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.3%
LOAD REGULATION| ±0.5%| ±0.3%
SETUP, RISE TIME| 2s, 50ms(only D mode) at full load
HOLD UP TIME (Typ.)**| 24ms(only D mode) at full load
INPUT
| VOLTAGE RANGE| B:19 ~ 36VDC C:36 ~ 72VDC D:72
~144VDC or 85 ~ 132VAC
EFFICIENCY (Typ.)| 75%| 77%| 79%| 77%| 80%| 82%
DC CURRENT (Typ.)| 8.5A/24V| 4.2A/48V| 2.1A/96V| 8.5A/24V| 4.2A/48V|
2.1A/96V
INRUSH CURRENT (Typ.)| D:22.5A/96VDC
LEAKAGE CURRENT| <0.75mA / 120VAC (SD-150D)
PROTECTION
| ****
OVERLOAD
| 105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE
| 16.8V ~ 20V/10% LOAD| 31.5 ~ 37.5V/10% LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
ENVIRONMENT
| WORKING TEMP.| -10 ~ +60℃ (Refer to output load derating curve)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 4)
| SAFETY STANDARDS| IEC/BS EN/EN 62368-1(for D type only), EAC TP TC 004
approved, design refer to AS/NZS 62368.1
WITHSTAND VOLTAGE| I/P-O/P:1.5KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMI CONDUCTION & RADIATION| Compliance to BS EN/EN55032
(CISPR32) Class B, EAC TP TC 020
EMS IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,6,8; BS EN/EN55035, BS
EN/ENV50204, light industry level, EAC TP TC 020
OTHERS
| MTBF| 2897.06K hrs min. Telcordia SR-332 (Bellcore) ; 419.6K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 19911050mm (LWH)
PACKING| 0.86Kg; 16pcs/14.5Kg/0.95CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at
24,48,96VDC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Features
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage
- 1500VAC I/O isolation
- -Built-in EMI filter, low ripple noise
- 100% full load burn-in test
- 24V and 48V input voltage design refer to LVD
- Low cost
- High reliability
- 2 years warranty
Mechanical Specification
Block Diagram
Derating Curve and Static Characteristics (24V)
Product Usage Instructions
Installation
Ensure the input voltage matches the specified range for the model you are using.
Connect the output terminals to your desired load.
Powering On
Apply power to the input within the specified voltage range.
Adjusting Settings
For voltage adjustment, refer to the specified voltage adjustment range.
Monitoring Performance
Observe the ripple and noise levels to ensure they are within the specified limits.
Troubleshooting
If encountering issues, refer to the protection features for guidance on possible causes.
FAQ
Q: What should I do if the device experiences a short circuit?
A: The converter is equipped with short circuit protection. Check the load and wiring for any faults.
Q: How can I adjust the output voltage?
A: The voltage adjustment range is specified. Use appropriate tools to make adjustments within this range.