MEAN WELL SD-1000 Series 1000W Single Output DC Converter Owner’s Manual

June 1, 2024
MEAN WELL

1000W Single Output DC-DC Converter
SD-1000 seriesMEAN WELL SD 1000 Series 1000W Single Output DC
Converter

Features:

  • 1U low profile 41mm
  • High power density 10.7w/inch³
  • 2000VAC I/O Isolation
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Output OK signal
  • Built-in remote ON-OFF control
  • Built-in remote sense function
  • Forced air cooling by built-in DC fan with fan speed control
  • 12V, 0.25A auxiliary output
  • 3 years warranty

https://www.meanwell.com/Upload/PDF/DC-DC_EN.pdf

GTIN CODE

MW Search:https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL| SD-1000L-12| SD-1000L-24| SD-1000L-48| SD- 1000H-12| SD-1000H-24| SD-1000H-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 24V| 48V| 12V| 24V| 48V
RATED CURRENT| 60A| 40A| 21A| 60A| 40A| 21A
CURRENT RANGE| 0 ~ 60A| 0 ~ 40A| 0 ~ 21A| 0 ~ 60A| 0 ~ 40A| 0 ~ 21A
RATED POWER| 720W| 960W| 1008W| 720W| 960W| 1008W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 11 ~ 15V| 23 ~ 30V| 46 ~ 60V| 11 ~ 15V| 23 ~ 30V| 46 ~ 60V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 50ms at full load
INPUT| VOLTAGE RANGE **Note.5| 19 ~ 72VDC| 72 ~ 144VDC
EFFICIENCY (Typ.)| 84%| 88%| 90%| 85%| 89%| 92%
DC CURRENT (Typ.)| 23.5A/48VDC| 11.6A/96VDC
INRUSH CURRENT (Typ.)| —–| 100A/96VDC
PROTECTION| OVERLOAD| 105 ~ 125% rated output power
Protection type : Constant current limiting, unit will shut down o/p voltage after about 5sec.
Re-power on to recover
OVER VOLTAGE| 16 ~ 19V| 30.8 ~ 35.2V| 62 ~ 68V| 16 ~ 19V| 30.8 ~ 35.2V| 62 ~ 68V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| REMOTE ON/OFF CONTROL| Please refer to function manual
OUTPUT OK SIGNAL| Open collector signal low when PSU turns on, maximum, sink current :10mA
ENVIRONMENT| WORKING TEMP.| -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.02%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 4)| SAFETY STANDARDS| IEC62368-1 CB approved by TUV, TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:2KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32), EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 898.2K hrs min. Telcordia SR-332 (Bellcore) ; 106.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 29512741mm (LWH)
PACKING**| 1.94Kg; 6pcs/12.6Kg/1.15CUFT

NOTE

  1. All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25℃ of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

  3. Tolerance : includes set up tolerance, line regulation and load regulation.

  4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
    (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

  5. Derating may be needed under low input voltages. Please check the derating curve for more details.

  6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL SD 1000 Series 1000W Single Output DC Converter - Mechanical
Specification

DC Input Terminal
Pin No. Assignment

Pin No. Assignment
1 DC INPUT V+
2 DC INPUT V-
3 FG ****

Control pin number assignment (CN51) : HRS DF11-10DP-2DS or equivalent

Pin No.| Assignment| Pin No.| Assignment| Pin No.| Assignment| Mating Housing| Terminal
---|---|---|---|---|---|---|---
1| +S| 5| AUX| 9| RCG| HRS DF11-10DS or equivalent| JST SPHD-002T-P0.5 or equivalent
2| -S| 6| AUXG| 10| NC
3| OUTPUT OK| 7| RC1| |
4| GND| 8| RC2| |

Block Diagram

BOOST fosc : 70KHz
PWM fosc : 90KHzMEAN WELL SD 1000 Series 1000W Single Output DC Converter -
Block Diagram

Derating Curve

MEAN WELL SD 1000 Series 1000W Single Output DC Converter - Derating
Curve

Static Characteristics

Function Description of CN51

Pin No. Function Description
1 +S Positive sensing. The +S signal should be connected to the positive

terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
2| -S| Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
3| O/P OK| Open collector signal, referenced to pin4(GND). Low when PSU turns on. The maximum sink current is 10mA and the maximum external voltage is 13V.
4| GND| These pins connect to the negative terminal (-V).
5| AUX| Auxiliary voltage output, 10.8~13.2V referenced to pin6(AUXG).The maximum load current is 0.25A.
6| AUXG| Auxiliary voltage output ground. The signal return is isolated from the output terminals(+V & -V).
7| RC1| Remote ON/OFF
8| RC2| Remote ON/OFF
9| RCG| Remote ON/OFF ground
10| NC| No connection

Function Manual

  1. Remote ON/OFF
    (1)Remote ON/OFF control becomes available by applying voltage in CN51
    (2)Table 1.1 shows the specification of Remote ON/OFF function
    (3)Fig.1.2 shows the example to connect Remote ON/OFF control function
    Table 1.1 Specification of Remote ON/OFFConnection Method| Fig. 1.2(A)| Fig. 1.2(B)| Fig. 1.2(C)
    ---|---|---|---
    SW Logic| Output on| SW Open| SW Open| SW Close
    Output off| SW Close| SW Close| SW Open

Fig.1.2 Examples of connecting remote ON/OFF
(A)Using external voltage source (B)Using internal 12V auxiliary output (C)Using internal 12V auxiliary output

  1. Output OK signal
    “Output OK” is an open collector signal.
    It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external signal; the other is sending out a voltage signal.
    2-1 Sink current:
    The maximum sink current is 10mA and the maximum external voltage is 13V.
    2-2 Voltage signal:**** Between O/P OK(pin3) and GND(pin4)| Output Status
    ---|---
    0 ~ 0.5V| ON
    12 ~ 13V| OFF

MEAN WELL SD 1000 Series 1000W Single Output DC Converter - Function Manual
4

  1. Remote Sense
    The remote sensing compensates voltage drop on the load wiring up to 0.5V.MEAN WELL SD 1000 Series 1000W Single Output DC Converter - Function
Manual 5

File Name:SD-1000-SPEC 2024-02-27MEAN WELL SD 1000 Series 1000W Single
Output DC Converter - Symbol 2 BS EN/EN62368-1 TPTC004 IEC62368-1

References