MEAN WELL SD-1000 Series 1000W Single Output DC Converter Owner’s Manual
- June 1, 2024
- MEAN WELL
Table of Contents
1000W Single Output DC-DC Converter
SD-1000 series
Features:
- 1U low profile 41mm
- High power density 10.7w/inch³
- 2000VAC I/O Isolation
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Output OK signal
- Built-in remote ON-OFF control
- Built-in remote sense function
- Forced air cooling by built-in DC fan with fan speed control
- 12V, 0.25A auxiliary output
- 3 years warranty
https://www.meanwell.com/Upload/PDF/DC-DC_EN.pdf
GTIN CODE
MW Search:https://www.meanwell.com/serviceGTIN.aspx
SPECIFICATION
MODEL| SD-1000L-12| SD-1000L-24| SD-1000L-48| SD-
1000H-12| SD-1000H-24| SD-1000H-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 12V| 24V| 48V| 12V| 24V| 48V
RATED CURRENT| 60A| 40A| 21A| 60A| 40A| 21A
CURRENT RANGE| 0 ~ 60A| 0 ~ 40A| 0 ~ 21A| 0 ~ 60A| 0 ~ 40A| 0 ~ 21A
RATED POWER| 720W| 960W| 1008W| 720W| 960W| 1008W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p|
150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p
VOLTAGE ADJ. RANGE| 11 ~ 15V| 23 ~ 30V| 46 ~ 60V| 11 ~ 15V| 23 ~
30V| 46 ~ 60V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 50ms at full load
INPUT| VOLTAGE RANGE **Note.5| 19 ~ 72VDC| 72 ~ 144VDC
EFFICIENCY (Typ.)| 84%| 88%| 90%| 85%| 89%| 92%
DC CURRENT (Typ.)| 23.5A/48VDC| 11.6A/96VDC
INRUSH CURRENT (Typ.)| —–| 100A/96VDC
PROTECTION| OVERLOAD| 105 ~ 125% rated output power
Protection type : Constant current limiting, unit will shut down o/p voltage
after about 5sec.
Re-power on to recover
OVER VOLTAGE| 16 ~ 19V| 30.8 ~ 35.2V| 62 ~ 68V| 16 ~ 19V| 30.8 ~
35.2V| 62 ~ 68V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically
after temperature goes down
FUNCTION| REMOTE ON/OFF CONTROL| Please refer to function
manual
OUTPUT OK SIGNAL| Open collector signal low when PSU turns on,
maximum, sink current :10mA
ENVIRONMENT| WORKING TEMP.| -20 ~ +60℃ (Refer to “Derating
Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.02%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 4)| SAFETY STANDARDS| IEC62368-1 CB approved by
TUV, TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:2KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC /
25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32), EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,6,8, BS
EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 898.2K hrs min. Telcordia SR-332 (Bellcore) ; 106.7K
hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 29512741mm (LWH)
PACKING**| 1.94Kg; 6pcs/12.6Kg/1.15CUFT
NOTE
-
All parameters NOT specially mentioned are measured at 48, 96VDC input, rated load and 25℃ of ambient temperature.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
-
Tolerance : includes set up tolerance, line regulation and load regulation.
-
The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) -
Derating may be needed under low input voltages. Please check the derating curve for more details.
-
The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
DC Input Terminal
Pin No. Assignment
Pin No. | Assignment |
---|---|
1 | DC INPUT V+ |
2 | DC INPUT V- |
3 | FG **** |
Control pin number assignment (CN51) : HRS DF11-10DP-2DS or equivalent
Pin No.| Assignment| Pin No.| Assignment| Pin No.|
Assignment| Mating Housing| Terminal
---|---|---|---|---|---|---|---
1| +S| 5| AUX| 9| RCG| HRS DF11-10DS or equivalent| JST SPHD-002T-P0.5 or
equivalent
2| -S| 6| AUXG| 10| NC
3| OUTPUT OK| 7| RC1| |
4| GND| 8| RC2| |
Block Diagram
BOOST fosc : 70KHz
PWM fosc : 90KHz
Derating Curve
Static Characteristics
Function Description of CN51
Pin No. | Function | Description |
---|---|---|
1 | +S | Positive sensing. The +S signal should be connected to the positive |
terminal of the load. The +S and -S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
2| -S| Negative sensing. The -S signal should be connected to the negative
terminal of the load. The -S and +S leads should be twisted in pair to
minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
3| O/P OK| Open collector signal, referenced to pin4(GND). Low when PSU turns
on. The maximum sink current is 10mA and the maximum external voltage is 13V.
4| GND| These pins connect to the negative terminal (-V).
5| AUX| Auxiliary voltage output, 10.8~13.2V referenced to pin6(AUXG).The
maximum load current is 0.25A.
6| AUXG| Auxiliary voltage output ground. The signal return is isolated from
the output terminals(+V & -V).
7| RC1| Remote ON/OFF
8| RC2| Remote ON/OFF
9| RCG| Remote ON/OFF ground
10| NC| No connection
Function Manual
- Remote ON/OFF
(1)Remote ON/OFF control becomes available by applying voltage in CN51
(2)Table 1.1 shows the specification of Remote ON/OFF function
(3)Fig.1.2 shows the example to connect Remote ON/OFF control function
Table 1.1 Specification of Remote ON/OFFConnection Method| Fig. 1.2(A)| Fig. 1.2(B)| Fig. 1.2(C)
---|---|---|---
SW Logic| Output on| SW Open| SW Open| SW Close
Output off| SW Close| SW Close| SW Open
Fig.1.2 Examples of connecting remote ON/OFF
(A)Using external voltage source (B)Using internal 12V auxiliary output
(C)Using internal 12V auxiliary output
- Output OK signal
“Output OK” is an open collector signal.
It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external signal; the other is sending out a voltage signal.
2-1 Sink current:
The maximum sink current is 10mA and the maximum external voltage is 13V.
2-2 Voltage signal:**** Between O/P OK(pin3) and GND(pin4)| Output Status
---|---
0 ~ 0.5V| ON
12 ~ 13V| OFF
- Remote Sense
The remote sensing compensates voltage drop on the load wiring up to 0.5V.
File Name:SD-1000-SPEC 2024-02-27 BS EN/EN62368-1 TPTC004 IEC62368-1
References