AIRTECHNIC ZLN6201B Cooker Hood User Manual

June 1, 2024
AIRTECHNIC

AIRTECHNIC-LOGO

AIRTECHNIC ZLN6201B Cooker Hood

AIRTECHNIC-ZLN6201B-Cooker-Hood-PRODUCT

Dear customer
Thank you for choosing our product. It is very important that you install the cooker hood correctly, to use it for a long time,efficiently and with reliability. Please read this User’s Manual carefully before installation and using

WHAT TO DO BEFORE 11 OPERATION

  • Please connect your cooker hood to a 220V grounded power line.
    WE SHALL ASSUME NO RESPONSIBILITY FOR ANY DAMAGE CAUSED BY UNGROUNDED LINES

  • Please connect your cooker hood to an autonomous exhaust air duct or chimney. It must not be connected to an exhaust system of other appliances.

  • Please plug your cooker hood to an earthed socket,while the buttons on the control panel are in off position.

  • Please install your cooker hood using the instructions within the packing.

  • The cooker hood must be at least 75 cm away from gas hobs and at least 65 cm from electric hobs.

  • Your cooker hood has the option of operating in reciculation mode without connection to exhaust duct,with active carbon filters. Under Request.

CONNECTION TO DUCTING FUNCTION

There is an air discharge outlet on your cooker hood.
Connect the outlet to the exhaust duct or chimney, using flexible aluminum pipe 120 mm in diameter. The exhaust ducting should be as short as possible and with the lowest possible number of bends. This is important for an efficient operation.

Please ensure that the exhaust outlet has a rain cap to prevent the entry of rain into the cooker hood.

RECIRCULATION FUNCTION

Note:
It is necessary to install carbon filters to use the recirculation function. For more information, please contact our sales department.
Please remove the cassette aluminum filter of the cooker hood, by pressing the latches inward, and install the ACTIVE CARBON FILTER that you have obtained from authorized AIRTECHNIC partners. Your cooker hood is ready to operate in recirculation mode without the need to connect to an exhaust duct.

ELECTRICAL CONNECTION & FUNCTIONS

AIRTECHNIC-ZLN6201B-Cooker-Hood-1

  • 0: Deactivate cooker hood
  • 1 : Selecting 1st speed
  • 2: Selecting 2nd speed
  • 3: Selecting 3d speed
  • : Activate/deactivate light

Note:
For simple cooking use speed levels 1 or 2.
For demanding cooking like frying, use speed level 3.

ALUMINIUM FILTER

The purpose of the cassette aluminum filter is to hold the oil particles during cooking. When the filter becomes clogged (the time depends on the usage), remove it and wash it with warm water and detergent, either by hand,or the dish washer. Let it dry before re-installing it.

ACTIVE CARBON FILTER
(RECIRCULATION FUNCTION)

Active carbon filter is used to remove odors and must be replaced every 4 months (not washable).

NOTE: Use only replacement filters from authorized AIRTECHNIC partners.

RECOMMENDATION

  • Do not replace filters while the cooker hood is operating.
  • Operate the cooker hood only when placing a cookware on the stove.
  • To transport the hood, follow the instructions on the original package.
  • Protect the hood from situations that may damage it such as moisture, water, drops, etc.
  • Keep the package away from children and dispose of it properly.
  • If you have a problem with your hood please contact only authorized AIRTECHNIC partners.

INSTALLATION AND IMPORTANT NOTES

  1. Prevent any foreign objects falling into the cooker hood and causing damage to the motor.
  2. Use aluminum duct instead of plastic one for air exhaust and install a protection grid at the outlet to prevent foreign objects from entering.
  3. Do not carelessly throw hot oil and foods on the stove.
  4. Do not leave any cookware on the burning stove.
  5. You must clean or replace the cooker hood filter periodically if it has accumulated too much oil .
  6. If there is no user signature on the warranty certificate,or the consumer makes misleading or incorrect statements, we reserve the right to take legal action. In such a case, warranty period will end immediately.
  7. Products without any warranty certificate are outside of warranty cover.
  8. Aluminum filters must be washed once a month (depending on usage).

DISCLAIMER
We bear no responsibility for fire or failures occurring due to user’s failing to comply with the instructions. This will also make the warranty void.

TECHNICAL INFORMATION

AIRTECHNIC-ZLN6201B-Cooker-Hood-5

TROUBLESHOOTING

****| COOKER HOOD IS NOT WORKING .| COOKER HOOD L/GHT/S NOT WORKING .| AIR SUCTION

/SLOW

| AIR EXHAUST IS LOW
---|---|---|---|---
Check the active carbon filter (if installed). It must be replaced every 4 months.| | | X|
Check the exhaust chimney if it is clear of foreign objects .| | | X|
Check the LED light.| | X| |
Check the aluminium filters . Must be washed once a month.| | | X| X
Check the light switch position (On I O ff) .| | X| |
Check the buttons if a speed is selected (1 , 2 or 3) and the device is not switched off.| X| | |
Check that the electrical connection is correct. Volt­ age 220-240V, on grounded power supply .| X| X| |
Check the fuses on the electrical panel.| | X| |

INSTALLATION OF THE COOKER HOOD

Use the cooker hood frame to mark the upper or back connection holes for the exhaust system (Figure 2). Cut the outlet hole and use 4 screws of 3.5 x 16 YHB to install the cooker hood onto the wall. For the back con- nection, drill two 7.8 mm in diameter, 45 mm deep holes and place two dowels of 8mm diameter. Screw the L brackets so as there is 10mm space between them and the holes (Figure 1). Mount your cooker hood to those brackets through the 2 slots in the back and fix the cook- er hood by tightening the L brackets. The wall must be intact and drilled without any damage otherwise it will not support the cooker hood. Connect the aluminum spi- ral pipe to complete installation. After installation of inox model hood, please remove the aluminum folio from the surface of the hood.

AIRTECHNIC-ZLN6201B-Cooker-Hood-3

AIRTECHNIC-ZLN6201B-Cooker-Hood-4

This product should not be treated as ordinary household waste.

Instead, it must be delivered to a suitable point for the collection and recycling of electrical and electronic equipment. By ensuring that this product is disposed of correctly, you are helping to prevent potential negative consequences for the environment and human health, which could be caused by improper handling of the product waste. For detailed information about product recycling, contact your local office,local household waste service or the shop where you purchased the product.

RESERVING THE RIGHT TO CHANGE THE CHARACTERISTICS WITHOUT AN EFFECT ON THE OPERATION OF THE APPLIANCE

Main Office ATHENS
© Paparrigopoulou 10 & Lagada,12132, Peristeri, Athens
211 – 705.55.00
@sales@airtechnic.gr

www.airtechnic.gr

Management System
ISO 14001:2015
Valid until:
2024-09-24
www.tuv.com
ID 9108650718

Factory – THIVA
© 4th km Thiva – Chalkida Hwy,32200, Thiva
22620 – 89.006
factory@airtechnic.gr

Factory – THESSALONIKI
9 End of Meandrou Str.,57013, Oraiokastro, Thessaloniki
2311 – 82.40.00
thessaloniki@airtechnic.gr

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals