AquaDeck TAQDECK Dual Lever Deck Mounted Tap Chrome Instruction Manual
- June 1, 2024
- AQUADECK
Table of Contents
Care Instructions for your AquaDeck Kitchen Tap
TAQDECK Dual Lever Deck Mounted Tap Chrome
To maintain the appearance of this tap, ensure that it is regularly cleaned
using only a clean, soft damp cloth. A solution of warm water and a mild
liquid detergent may be used where necessary, and then the fitting rinsed
thoroughly and wiped dry.
Any other cleaning action could invalidate your warranty.
You MUST NOT use abrasive cleaners, scouring and acidic cleaners under any
circumstances as this WILL damage the integrity of the surface finish. Avoid
contact with all solvents (including chlorinated solvents, ketones or
acetones) as these may result in surface deterioration or etching. Also avoid
contact with any harsh household chemicals such as oven cleaners, drain
cleaners, rust removers, paint strippers and Stainless-Steel cleaner. Where
the tap has a removable aerator on the spout exit it can be removed and
cleaned periodically with water to maintain optimum flow performance.
Important Technical Data:
- Min / Max operating pressure: 0.1 bar – 5.5 bar*
- Recommended / Maximum hot water temperature: 46 – 70°C*
- Tap hole size and centres: ∅22-35mm
- This product is either WRAS approved or manufactured in accordance with recognised European standards.
- Please ensure that your kitchen mixer is fitted in accordance with Local Water Byelaws.
- Hot and cold supply pressures should be as closely balanced as possible for best results.
- Supply pipes should maintain the maximum diameter until immediately before the fitting.
- Always use the manufacturer’s tail pipes provided – use of non-manufacturer tails will invalidate warranty.
- The differential between the hot and cold water temperatures should be sufficient to allow correct mixing function.
- This tap has been 100% assembly tested therefore, you may expect a small residual amount of water to remain in the tap or inner packaging when delivered. This is normal and any water marks can be removed using the care advice above.
*If these temperatures or pressures are exceeded, even for short periods, damage can result. In these instances, a thermostatic mixing or pressure reducing valve should be installed.
5 Year Warranty Terms and Conditions
In the event of any problem or defect in the materials or workmanship of your
new Leisure mixer within FIVE years of purchase, the purchaser’s sole remedy
shall be the replacement (at the manufacturer’s discretion) of all or any part
of the product that is defective. All working parts, valves and O rings are
guaranteed for a period of FIVE years from purchase. Chrome decorative surface
finishes are guaranteed for FIVE years from the date of purchase and other
decorative finishes (including granite finishes, matt black, satin steel,
satin bronze) are guaranteed for THREE years from date of purchase. The
warranty extends to the original purchaser only.
You should retain a copy of your dated invoice as proof of purchase to
validate any claims under this guarantee as claims without proof of purchase
may not be accepted. Surface scratches and marks caused through careless or
improper installation or accidental damage are NOT covered by this warranty.
Any product returns must be packaged with all associated tap parts and clear
details of the installation name and address and the customer service number
displayed on the return packaging.
IMPORTANT: All warranties extend only to mixers used for normal domestic
use in the UK or Ireland and that the care, installation and maintenance
instructions have been fully observed.
Due to our continual product development, we may not be able to provide an
identical replacement for a defective product throughout the guarantee period.
Where an identical product is no longer available, we will supply the nearest
equivalent from our then current product range. In assessing your claim, we
must be given the opportunity to inspect the product as installed prior to
removal.
No other warranties, express or implied, are made, including merchantability
or fitness for a particular purpose. Under no circumstances shall the
manufacturer be liable for any loss or damage arising from the purchase, use
or inability to use this product, or for any special, indirect, incidental, or
consequential damages. No liability is accepted for consequential damage to
other household fixtures, fittings or furnishings arising from this claim,
even if attached to the product. No installer, dealer, agent or employee of
Aga Rangemaster Limited has the authority to modify the obligations or
limitations of this warranty.
Installation Preparation:
All parts should be removed from their packaging and inspected for
completeness and transit damage prior to installation.
IMPORTANT: Before installation, it is essential that you thoroughly flush
through the supply pipes in order to remove any remaining dirt, solder, swarf,
sediment or impurities from your water system. Failure to carry out this
simple procedure could cause significant damage to the workings of the tap,
reduce flow rates and invalidate the warranty. We recommend installing
isolation valves to both the hot and cold feed pipes in an accessible
position. This will help to ease any future required maintenance to the
product.
- Shut off the water heating system and ensure that the mains stopcock is closed.
- Ensure both hot and cold water supplies are isolated before commencing installation.
- If replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool, the tap hole areas should be free from dirt and sealant. You should ensure that the product will both fit into the depth of the mounting surface available and reach the required outlet positions before installation.
- Loosely position the tap to check if any alteration to the existing pipework is required, if this is the case do this now.
Installation
- Place the upper seal (D) over the hot and cold inlets (C) onto the base of the mixertap body (B).
- Place the mixertap (B) onto the sink and pass the inlet pipes (C) through the tapholes. With the tap in place check that the inlet pipes (C) meet the hot and cold water feeds. If further adjustment to the plumbing is required do this now. The hot water should be connected to the left hand side of the tap when viewed from the front.
- Fasten the fixing nuts (E) securely onto inlets (C) fixing the tap into its correct location, do not over tighten nuts (E).
- Connect the inlets (C) to the water supplies using ½” BSP compression fittings or similar.
Key | Description |
---|---|
A | Spout x 1 |
B | Tap body x 1 |
C | Hot and Cold Inlets x 2 |
D | Upper Seal x 1 |
E | Fastening Nut x 2 |
After installation:
Once you have visually checked the installation and all connections, ensure
that all other fittings are closed except the new tap which should be left
open. Turn on your water heating system and ensure that your mains stopcock is
open. Reconnect both the hot and cold-water supplies to this fitting. Check
the function of flow and function of hot, cold and mixed water. Turn off the
tap and check carefully for any leaks around all connections on the fitting
and adjoining plumbing. If pressure testing equipment is available check the
installation to the maximum recommended pressure. Clean the tap to remove any
marks created during installation. Protect the newly installed tap from damage
by placing a packaging bag over the product. The installation should be
periodically checked for damage, if the property is left unattended for a
prolonged period, we recommend isolating water supplies.
Care and Aftersales Enquiries – Call 01926 457628 Option 4
Please Retain these Instructions.
Documents / Resources
|
AquaDeck TAQDECK Dual Lever Deck Mounted Tap
Chrome
[pdf] Instruction Manual
TAQDECK Dual Lever Deck Mounted Tap Chrome, TAQDECK, Dual Lever Deck Mounted
Tap Chrome, Deck Mounted Tap Chrome, Mounted Tap Chrome, Tap Chrome, Chrome
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>