TECH WSR-01 P Temperature Controller Instruction Manual
- June 1, 2024
- TECH
Table of Contents
WSR-01 P / WSR-01 L
WSR-02 P / WSR-02 L
WSR-03 P / WSR-03 L
TECH STEROWNIKI II Sp. z o.o.
ul. Biała Droga 31
34-122 Wieprz
Service
[PL] tel: +48 33 875 93 80
serwis.sinum@techsterowniki.pl
[CZ] tel: +420 733 180 378 www.tech-controllers.cz
cs.servis@tech-reg.com
[DE] tel. +48 33 875 93 80 www.tech-controllers.com
support.sinum@techsterowniki.pl
[RO] tel. +40 785 467 825
www.techsterowniki.pl/ro
contact@tech-controllers.ro
[ES] tel. +48 33 875 93 80 www.tech-controllers.com
support.sinum@techsterowniki.pl
[RU] +375 3333 000 38 (WhatsАpp, Viber, Telegram)
service.eac@tech-reg.com (RU)
[EN] tel: +48 33 875 93 80 www.tech-controllers.com
support.sinum@techsterowniki.pl
[SK] tel: +421 918 943 556 www.tech-reg.sk
sk.servis@tech-reg.com
[NL] tel. +31 341 371 030 www.tech-controllers.com
e-mail: info@eplucon.nl
[HU] tel. +36-300 919 818, +36 30 321 70 88
www.tech-controllers.hu szerviz@tech-
controllers.com
[UA] tel. +38 096 875 93 80 www.tech-controllers.com
servis.ua@tech-controllers.com
Wyprodukowano w Polsce
www.tech-controllers.com/manuals
Made in Poland
WSR-02 / WSR-03 WSR-01
Description
The WSR-01 / WSR-02 / WSR-03 light switch with regulator is a functional
device for controlling the room temperature, lighting or other device from
switch or via the Sinum Central device. In the Sinum Central device, the user
can program the conditions for specific automations. Communication with the
Sinum Central device is wireless.
WSR-01 / WSR-02 / WSR-03 has a built-in temperature and humidity sensor and a
light sensor that adjusts the brightness of the button backlight to the
current brightness level in the room. Optionally, a floor temperature sensor
can be attached to the device.
(1) – Switch registration button
(2) – Regulator registration button
(3) – Actual time
(4) – Actual temperature
(5) – Pre-set temperature
(6) – Return button
(7) – Navigation buttons
(8) – Menu button
(9) – Floor sensor
NOTE!
- The drawings and the number of buttons may be different depending on the version you have.
- The maximum load of a single output for LED lighting is 200W.
How to register the device in the sinum system
Enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the **Settings > Devices > Wireless devices
(+) . Then briefly press the registration button (1) or (2) on the device. The regulator and the switch are treated as two individual devices and should be registered separately. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room.
INFO:** When registering the regulator, the humidity sensor and floor sensor (if it is connected) will also be registered automatically.
Menu
Hold down the Menu buttton until appears option. Change options with and
buttons, confirm with Menu button. Options available:
– temperature sensor calibration,
– factory reset ( , – value change, Menu – confirm )
– software information.
Operation
-
Pressing button the displayed parameter changes: current temperature -> humidity -> floor temperature (after connecting the sensor)
-
Heating/cooling control is possible after assigning the controller in the Sinum Central device to a virtual thermostat. On the display may appear:
– Icon (cooling mode) – the need for cooling
– Icon (heating mode) – the need for heating
– No icon – no need for heating/cooling -
Icon informs about active manual mode
-
Changing the preset temperature with the , buttons and confirming with the Menu button. The set temperature will be permanent.
If the regulator is assigned to a virtual thermostat, after changing the temperature, use the and to specify the time range of the set temperature [0 ÷ 24h, Con (permanently) or Off (inactive change)], confirm with the Menu button . -
Button lock – pressing the Menu button will activate the function ; use the or to select “yes” or “no” (automatic lock on/off). Confirm with the Menu button or wait approx. 5 sec. Holding and simultaneously until the padlock icon disappears unlocks the buttons.
-
-
EXIT and MENU button regulator functions:
Pressing EXIT:
- change of the displayed parameter: current temperature, air humidity, floor temperature (optional)
- exit from the menu
EXIT hold:
- manual control off
Pressing MENU:
- button lock option is displayed
- next menu function
- confirmation of settings
Holdig MENU:
-
enter the menu
-
-
WSR-03 switch buttons
The outermost buttons are used to control the lighting whereas the middle button serves as a programmable button. Using this button the user may activate the automation which has been previously programmed in the Sinum central device.
Technical data
|
Switch
|
Regulator
---|---|---
Power supply|
230V±10%/50Hz
|
230V±10%/50Hz
Max. power consumption|
1W
|
0,1W
Maximum output load|
4A (AC1)* / 200W (LED)
|
–
Operation temperature|
5°C ÷ 50°C
Communication|
Wireless (WTP 868 MHz)
Dimensions [mm]|
164 x 84 x 16
Installation|
Flush-mountable (electrical box 2 x ø60 mm)
* AC1 load category: single-phase, resistive or slightly inductive AC load.
Notes
TECH Controllers is not responsible for any damages resulting from improper
use of the system. The range depends on the conditions in which the device is
used and the structure and materials used in the object construction. The
manufacturer reserves the right to improve devices, update software and
related documentation. The graphics are provided for illustration purposes
only and may differ slightly from the actual look. The diagrams serve as
examples. All changes are updated on an ongoing basis on the manufacturer’s
website.
Before using the device for the first time, read the following regulations
carefully. Not obeying these instructions may lead to personal injuries or
controller damage. The device should be installed by a qualified person. It is
not intended to be operated by children. It is a live electrical device. Make
sure the device is disconnected from the mains before performing any
activities involving the power supply (plugging cables, installing the device
etc.). The device is not water resistant.
The product may not be disposed of to household waste containers. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.
EU Declaration of conformity
Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122)
Hereby, we declare under our sole responsibility that the
WSR-01 / WSR-02 / WSR-03 is compliant with Directive 2014/53/UE.
Wieprz, 01.12.2023
Paweł Jura Janusz Master
Prezesi firmy
The full text of the EU declaration of conformity and the user manual are
available after scanning the QR code or at
www.tech-controllers.com/manuals
Documents / Resources
| TECH
WSR-01 P Temperature
Controller
[pdf] Instruction Manual
WSR-01 P, WSR-01 L, WSR-02 P, WSR-02 L, WSR-03 P, WSR-03 L, WSR-01 P
Temperature Controller, WSR-01 P, Temperature Controller, Controller
---|---
References
- controllers.com
- Intelligens fűtés-hűtés, fűtési-hűtési megoldások - TECH vezérlők gyártója | TECH vezérlők
- Sinum - TECH Controllers
- Intelligent heating, smart heating solutions - manufacturer of controllers | TECH Controllers
- Manuals - TECH Controllers
- TECH Controllers - Teplo ve Vašem domě
- TECH Controllers - Teplo vo Vašom dome
- Soluţia de acasă de economisire a energiei - producător de controlere I Tech-Controllers
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>