nedis PIM30012EGY Power Inverter Installation Guide

June 1, 2024
nedis

nedis PIM30012EGY Power Inverter

Specifications

  • Product: Power Inverter (300/600 Watt)
  • Models: PIM30012EGY, PIM30012FGY, PIM60012EGY, PIM60012FGY
  • Input: 12V DC
  • Output: 230V AC
  • Waveform: Modified Sine Wave

Product Usage Instructions

Mounting the Power Inverter

1. Keep at least 50cm of space between the power inverter and the wall for ventilation.

2. Securely mount the power inverter using screws after marking and drilling holes.

Connecting the Power Inverter

1. Wear protective gloves and use insulated tools when connecting power cables.

2. Connect power cables A2 to the cable terminals B1B2 on the rear of the power inverter.

3. Connect the other end of the power cables to a 12 V battery system, ensuring correct polarity.

Powering a Socket Device

1. Ensure the target device is switched off before connecting it to the power inverter.

2. Plug the device’s power plug into the power socket B3.

3. Turn on the power switch B5; the power indicator LED B4 will illuminate.

Powering to USB Device

1. Connect a USB cable to the USB port B7 of the power inverter.

2. Plug the other end of the USB cable into your device.

3. Turn on the power switch B5 to supply power; the power indicator LED B4 will light up.

FAQ

  • What should I do if my target device is not receiving power?
    • If the target device is not receiving power, check the indicator LEDs and listen for alarms. Refer to the troubleshooting section in the manual for assistance.
  • How can I troubleshoot common problems with the power inverter?
    • If you encounter issues like overvoltage shutdown, overload protection, high-temperature shutdown, or output short circuit, follow the solutions provided in the troubleshooting section of the manual.

Quick start guide

Power Inverter

(300/600 Watt)

  • PIM30012EGY PIM30012FGY
  • PIM60012EGY PIM60012FGY

For more information see the extended manual online: ned.is/pim30012egy

Intended use

This product is a power inverter to converts 12 V DC to 230 V AC. 4 The modified sine wave power inverters are less suitable for devices with a motor. Use a pure sine wave power inverter (PIPxxxxxGY).
Only use this product in combination with class II devices.

Do not use this product with:

  • Devices that exceed the rated power of the inverter.
  • Capacitive and perceptual load devices such as air conditioning, high power drills, fridges, microwave ovens, or blenders.
  • Devices that have strict power supply requirements, such as precision measuring equipment.

The product is intended for indoor use only.

Any modification of the product may have consequences for safety, warranty and proper functioning.

The product is not intended for professional use.

Main parts (image A)

nedis-PIM30012EGY-Power-Inverter-FIG \(1\),.,..,

  1. Power inverter
  2. Power cables

Main parts (image B)

nedis-PIM30012EGY-Power-Inverter-FIG \(2\)

  1. Cable terminal +
  2. Cable terminal –
  3. Power socket
  4. Power indicator LED
  5. Power switch
  6. Fault indicator LED
  7. USB port

Safety instructions

WARNING

  • Ensure you have fully read and understood the instructions in this document before you install or use the product. Keep the packaging and this document for future reference.
  • Only use the product as described in this document.
  • Do not install the product next to flammable materials.
  • Do not place the product in areas with high temperatures or direct sunlight.
  • Do not cover or obstruct the ventilation openings on the product.
  • Do not immerse the product in water or other liquids.
  • Do not expose the product to water, rain, moisture, or high humidity.
  • Do not operate the product close to combustible gas or open fire.
  • Do not operate appliances that may feed power back into the power inverter.
  • Do not open the product, there are no user-serviceable parts inside.
  • Disconnect the product from the power source before cleaning.
  • Disconnect the product from the power source before service and when replacing parts.
  • Do not use the product if a part is damaged or defective. Replace a damaged or defective product immediately.
  • Do not let children play with the packaging material. Always keep the packaging material out of the reach of children.
  • Always keep the power cable and the product away from the usual walkways.
  • Do not drop the product and avoid bumping.
  • Do not use aggressive chemical cleaning agents when cleaning the product.
  • This product may only be serviced by a qualified technician for maintenance to reduce the risk of electric shock.

Mounting the power inverter

  • Keep at least 50cm of space to the wall from the fans on the rear of the power inverter.
  1. Hold the power inverter in the desired position.
  2. Mark four holes with a pencil using the power inverter as a template.
  3. Drill the holes using a power drill and a drill bit.
  4. Mount the power inverter on the desired position using screws.

Connecting the power inverter (Image C)

nedis-PIM30012EGY-Power-Inverter-FIG \(3\)

  • Wear protective gloves when installing the power cables.
  • Use tools with insulated handles when installing the power cables.
  1. Connect the power cables A2 to the cable terminals on the rear of the power inverter B1B2.
  2. Connect the other end of the power cables to a 12 V battery system.

Make sure the polarity matches the polarity of the battery.

Powering a socket device

Make sure the polarity matches the polarity of the battery.

  1. Plug the power plug from a target device into the power socket B3.
  2. Set the power switch B5 to ON.

The power indicator LED B4 switches on.

  • Do not load the power inverter more than 80% during long use (>1 hour).

Powering a USB device

  1. Plug a USB cable into the USB port B7 of the power inverter.
  2. Plug the other end of the USB cable into your target device.
  3. Set the power switch B5 to ON.

The power indicator LED B4 switches on.

Troubleshooting

Power LED| Fault LED| Alarm| Possible cause| Possible solution
---|---|---|---|---
Off| Off| No| The power inverter is switched off| Switch on the power inverter.
| | | The battery is empty.| Recharge the battery.
| | | | Replace the battery.
On| Off| Yes| Low voltage alarm| Recharge the battery.
| | | | Replace the battery.
On| Off| Yes| Low voltage shutdown| Recharge the battery.
| | | | Replace the battery.
Power LED| Fault LED| Alarm| Possible cause| Possible Solution
---|---|---|---|---
On| On| No| Over voltage shutdown| Check the battery voltage.

The power inverter will function as normal again when the voltage is within the specified range.

On| On| No| Overload protection| Reduce the load on the power inverter.
On| On| Yes| High-temperature shutdown| Let the product cool down.

The power inverter will function as normal again when it is cooled down.

On| On| No| Output short circuit| Remove the target device from the power inverter.

Check the device for short circuits.

Remove the short circuit from the output and restart the power inverter to resume normal functioning.

If the target device is not receiving power, look at the indicator LEDs and listen for alarms. The table below shows what the combinations of lights and sounds mean.

Disposal

The product is designated for separate collection at an appropriate collection point. Do not dispose of the product with household waste.
For more information, contact the retailer or the local authority responsible for the waste management.

SCAN

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

nedis User Manuals

Related Manuals