Specifications:
- Product Name : Power Inverter (1000 Watt)
- Model Variants: PIM100012EGY, PIM100012FGY, PIM100024EGY, PIM100024FGY
- Input Voltage : 12/24 V DC
- Output Voltage: 230 V AC
- Waveform: Modified Sine Wave
Product Usage Instructions
Mounting the Power Inverter:
- Keep at least 50cm of space to the wall from the fans on the rear of the power inverter.
- Hold the power inverter in the desired position.
- Mark four holes with a pencil using the power inverter as a template.
- Drill the holes using a power drill and a drill bit.
- Mount the power inverter on the desired position using screws.
Connecting the Power Inverter:
- Wear protective gloves when installing the power cables.
- Use tools with insulated handles when installing the power cables.
- Connect the power cables A2 to the cable terminals on the rear of the power inverter B1B2.
- Connect the other end of the power cables to a 12/24 V battery system.
- Ensure polarity matches the battery’s polarity.
Powering a Socket Device:
- Ensure the target device is switched off before connecting it.
- Plug the power plug from a target device into the power socket B3.
- Set the power switch B5 to ON.
- The power indicator LED B4 switches on.
- Do not exceed 80% load on the inverter during long use (>1 hour).
Powering to USB Device:
- Plug a USB cable into the USB port B6 of the power inverter.
- Plug the other end of the USB cable into your target device.
- Set the power switch B5 to ON.
- The power indicator LED B4 switches on.
Troubleshooting:
If the target device is not receiving power, look at the indicator LEDs and listen for alarms. Refer to the table below for possible causes and solutions based on LED indications and alarms.
FAQ
- Q: What should I do if my inverter’s fault LED is on?
- A: If the fault LED is on, it could be due to over-voltage shutdown, overload protection, high-temperature shutdown, or output short circuit. Follow the troubleshooting guide provided in the manual to resolve the issue.
- Q: Can I use this inverter with a 24V battery system?
- A: Yes, this inverter is designed to work with both 12 V and 24 V battery systems. Ensure proper connections and polarity matching for safe operation.
Quick start guide
Power Inverter (1000 Watt)
PIM100012EGY PIM100012FGY
PIM100024EGY PIM100024FGY
For more information see the extended manual online: ned.is/pim100012egy
Intended use
This product is a power inverter to convert 12/24 V DC to 230 V AC.
Check the specifications of your model.
The modified sine wave power inverters are less suitable for devices with a
motor. Use a pure sine wave power inverter (PIPxxxxxGY).
Only use this product in combination with class II devices.
Do not use this product with:
- Devices that exceed the rated power of the inverter.
- Capacitive and perceptual load devices such as air conditioning, high power drills, fridges, microwave ovens, or blenders.
- Devices that have strict power supply requirements, such as precision measuring equipment.
The product is intended for indoor use only.
Any modification of the product may have consequences for safety, warranty and
proper functioning.
The product is not intended for professional use.
Main parts (image A)
- Power inverter
- Power cables
Main parts (image B)
- Cable terminal +
- Cable terminal –
- Power socket
- Power indicator LED
- Power switch
- USB port
- Fault indicator LED
Safety instructions
WARNING
- you have fully read and understood the instructions in this document before you install or use the product. Keep the packaging and this document for future reference.
- Only use the product as described in this document.
- Do not install the product next to flammable materials.
- Do not place the product in areas with high temperatures or direct sunlight.
- Do not cover or obstruct the ventilation openings on the product.
- Do not immerse the product in water or other liquids.
- Do not expose the product to water, rain, moisture, or high humidity.
- Do not operate the product close to combustible gas or open fire.
- Do not operate appliances that may feed power back into the power inverter.
- Do not open the product, there are no user-serviceable parts inside.
- Disconnect the product from the power source before cleaning.
- Disconnect the product from the power source before service and when replacing parts.
- Do not use the product if a part is damaged or defective. Replace a damaged or defective product immediately.
- Do not let children play with the packaging material. Always keep the packaging material out of the reach of children.
- Always keep the power cable and the product away from the usual walkways.
- Do not drop the product and avoid bumping.
- Do not use aggressive chemical cleaning agents when cleaning the product.
- This product may only be serviced by a qualified technician for maintenance to reduce the risk of electric shock.
Mounting the power inverter
Keep at least 50cm of space to the wall from the fans on the rear of the power inverter.
- Hold the power inverter in the desired position.
- Mark four holes with a pencil using the power inverter as a template.
- Drill the holes using a power drill and a drill bit.
- Mount the power inverter on the desired position using screws.
Connecting the power inverter (Image C)
Wear protective gloves when installing the power cables.
Use tools with insulated handles when installing the power cables.
- Connect the power cables A2 to the cable terminals on the rear of the power inverter B1B2.
- Connect the other end of the power cables to a 12/24 V battery system
Make sure the polarity matches the polarity of the battery.
Powering a socket device
Make sure the target device is switched off before connecting it.
- Plug the power plug from a target device into the power socket B3.
- Set the power switch B5 to ON.
The power indicator LED B4 switches on.
Do not load the power inverter more than 80% during long use (>1 hour).
Powering a USB device
- Plug a USB cable into the USB port B6 of the power inverter.
- Plug the other end of the USB cable into your target device.
- Set the power switch B5 to ON.
The power indicator LED B4 switches o
Troubleshooting
If the target device is not receiving power, look at the indicator LEDs and listen for alarms. The table below shows what the combinations of lights and sounds mean.
Power LED| Fault LED| Alarm| Possible cause|
Possible Solution
---|---|---|---|---
Off| Off| No| The power inverter is switched off| Switch on the power
inverter.
| | | The battery is empty.| Recharge the battery.
| | | | Replace the battery.
On| Off| Yes| Low voltage alarm| Recharge the battery.
| | | | Replace the battery.
On| Off| Yes| Low voltage shutdown| Recharge the battery.
| | | | Replace the battery.