APOGEE 247 Launch Monitor Measures Ball and Club Data User Guide
- June 1, 2024
- APOGEE
Table of Contents
APOGEE 247 Launch Monitor Measures Ball and Club Data
Specifications
- Designed and Assembled in the USA
- Ceiling Bracket
- Mounting Slot
- Cable Inputs
- System Status Indicator (SSI)
- System Connection Indicator (SCI)
- Center Camera
- Offset Camera
- APOGEE Laser Indicator
- Microphone
- Infrared Lighting System
Product Usage Instructions
Installation
- Identify the centerline of your simulator using reflective dots and a laser level.
- Measure the distance from the turf to the ceiling to determine Tee to APOGEE distance.
- Detach the APOGEE Mount from the unit and attach it to the ceiling using provided screws.
- Ensure the mount is parallel to the screen by adjusting until the laser bisects all center holes.
- Secure the APOGEE unit to the mount by tightening screws.
Wiring
Connect the power and network cables into the back of the APOGEE unit for
proper functionality.
FAQ
What should I do if the System Status Indicator (SSI) light does not change
color?
If the SSI light does not change color, check the connections and power supply
to ensure proper functioning of the APOGEE unit.
How do I calibrate the APOGEE Launch Monitor?
To calibrate the APOGEE Launch Monitor, refer to the included Calibration
Template and follow the instructions provided in the user guide.
GETTING STARTED
WELCOME TO APOGEE
Before installation, please review the included components and familiarize
yourself with the Launch Monitor.
To complete installation, you will need:
- Ladder
- Plumb bob
- Measuring Tape
- Pencil
- Laser Level
- Drill
- Stud Finder
For users mounting APOGEE in custom, or non-simulator bay environments, additional hardware may be required to achieve functional launch monitor placement.
PACKAGED ITEMS
HARDWARE
-
APOGEE Launch Monitor
-
APOGEE Ceiling Mount
PAPER -
APOGEE Calibration Template
- Use this to complete calibration inside the APOGEE Intelligent Dashboard Software
-
“Hey APOGEE,” Voice Command Instruction
- User Guide to the Voice Command feature
-
APOGEE User Guide
CABLES -
CAT6 Cable (50’)
-
USB to CAT6 Network Adapter
-
Power Cable
TOOLS AND EQUIPMENT -
Laser Level
-
Mounting Hardware
- Wood Screws
- Drywall Anchors
- Fender Washer
MISCELLANEOUS
-
Reflective Dots
HARDWARE
OVERVIEW
-
A. Ceiling Bracket
-
B. Mounting Slot
-
C. Mounting Screws
-
D. Cable Inputs
-
E. System Status Indicator (SSI)
The APOGEE logo color will change according to status -
F. System Connection Indicator (SCI)
The SCI lightbar will change color upon error -
G. Center Camera
-
H. Offset Camera
-
I. APOGEE Laser Indicator
Projects ball placement pattern on ground -
J. Microphone
-
K. Infrared Lighting System
These are internal, with the light passing through the acrylic faceplate.
INSTALLATION
APOGEE should be installed on a flat, level surface and has to be installed between 9’ – 10’ feet off the hitting surface. The APOGEE mount is threaded and can be attached to a universal projector mount for ceiling heights over 10’ in height. For secure installation, wooden backing is recommended. APOGEE has a fixed position Tee Box. Installation starts with YOU knowing where you want your Tee Box to be, and installing APOGEE in the correct position to accommodate it. Accuracy of APOGEE depends on an accurate installation.
-
To identify the centerline of your simulator, place reflective dots at the center of your Tee Box (desired hitting area) and the center point of your screen. Align the included laser level with the two dots to determine the centerline of your simulator.In the majority of simulators, this will be in the center of your space.
NOTE: If your mat is not centered in your simulator space, the centerline at the screen should match the offset of the mat. -
Measure the distance from the turf to ceiling and use the table below to find your “Tee to APOGEE” distance. Using your “Tee to APOGEE” distance, measure forward from the center of your desired tee location and place a mark on the floor with one of the included Reflective Dots. Using a plumb bob, place a corresponding mark with a pencil on the ceiling.
Ceiling Height in Centimeters|
Tee to APOGEE
---|---
274-279| 53
279-287| 56
287-292| 58
292-300| 61
300-305| 64
Ceiling Height in Inches|
Tee to APOGEE
---|---
108”-110”| 21”
110”-113”| 22”
113”-115”| 23”
115”-118”| 24”
118”-120”| 25”
-
The APOGEE Mount ships attached to APOGEE. Detach it from APOGEE by loosening the 2 screws, front and back.
DO NOT REMOVE SCREWS -
Attach the APOGEE Mount using one of the included screws and fender washer through the center hole on the mount to the mark on the ceiling.
DO NOT TIGHTEN FULLY AT THIS POINT
Note: Screws included for mounting to Drywall or wooden surface. -
To ensure the mount is parallel to the screen, rotate and adjust the mount until the laser bisects all center holes and tighten down center screw.
-
Add additional screws to secure the APOGEE Mount to the ceiling.
-
Slide APOGEE up into the mount and then over and down into the slotted section.
-
Tighten the 2 screws in the front and 2 screws in the back to secure APOGEE to the mount.
WIRING
Connect the power and the network cable into the back of the APOGEE unit.
GET ACQUAINTED
WITH APOGEE
APOGEE is a ceiling mounted, photometric Launch Monitor.
It measures spin without the need for specialty golf balls and records club
data without marked clubs.* The product includes: Voice Commands, Laser
Indicator, Point of Impact Replay, Auto Diagnostic and Auto Calibration.
Note: Some lighting environments and some custom club finishes may require a metallic sticker for accurate Club Face Angle data. However, trajectory data is derived from the measured ball characteristics.
THE APOGEE INTELLIGENT DASHBOARD (AID)
THE APOGEE INTELLIGENT DASHBOARD (AID) – is a standalone software to help owners manage their APOGEE Launch Monitor. The system includes diagnostic and automated calibration features to make identifying and solving any technical problems simple.
-
CALIBRATION – Launches the Automated Calibration Wizard (ACW). Enabling Calibration will check installation alignment and adjust apertures for ambient light in the area. The ACW guides APOGEE owners through any necessary next steps.
-
FIRMWARE UPDATE – Updates APOGEE Launch Monitor Firmware.
-
DEVICE RESTART – Reboots the APOGEE launch monitor.
-
RESET TO DEFAULTS – Resets APOGEE Launch Monitor to its original factory settings.
USER PREFERENCES- APOGEE Laser Indicator – Users can enable or disable this feature
- HEY APOGEE Voice Command System– Users can enable or disable this feature
-
STATUS – See real-time status of network connections, the camera system, and the internal temperature of your APOGEE Launch Monitor.
-
SUPPORT – View and Submit Logs to TruGolf Support Team.
Your contact information will be connected with these reports.
WITH APOGEE
“HEY APOGEE” VOICE COMMAND system can be enabled or disabled inside the AID.
This proprietary voice command system has been designed to help increase the
speed and convenience of your indoor golf round. The system is activated upon
hearing “HEY APOGEE.”APOGEE LASER INDICATOR can be enabled or disabled inside
the AID. This visual aid shows users appropriate places to tee the ball for
the most accurate readings.
TEE BOX is the acceptable hitting area where users can place the ball – Tee Box measures 10” W x 8” D.
SYSTEM STATUS INDICATOR (SSI) – This is the LED Indicator located on the front of the APOGEE Launch Monitor.
- Blue – Unit is Operational
- Yellow – Calibration in Progress
- Red – User should launch APOGEE INTELLIGENT DASHBOARD to check STATUS AND SUPPORT for diagnosis
SYSTEM CONNECTION INDICATOR (SCI) – This is the LED Indicator inside the APOGEE Text on the face plate of the APOGEE Launch Monitor.
- Orange – System Booting
- Yellow – Searching for Connection
- White – Connected to APOGEE INTELLIGENT DASHBOARD
- Purple – Calibration in Progress
- Blue – Connected to E6 CONNECT
- Red – Issue Found. Users should launch APOGEE INTELLIGENT DASH BOARD to check STATUS AND SUPPORT for diagnosis
WITH APOGEE
CENTER CAMERA
This is the camera in the center of the APOGEE Launch Monitor.
OFFSET CAMERA
This is the camera offset from the center of the APOGEE Launch Monitor.
MICROPHONE
The Microphone is located in the center of the APOGEE Launch Monitor.
NOTES
APOGEE requires one of these compatible turf types for the TEE BOX
- TruGolf Hitting Mat
- Country Club Elite
- For additional compatible Turf Solutions, please contact your Sales Representative
APOGEE is powered by E6 CONNECT
The Minimum System Requirements are:
- Intel i5 Processor
- 8GB RAM
- Nvidia 1070
- 25GB of Hard Drive Space
- Windows 10 64-Bit
- Internet Connection
“HEY APOGEE”
VOICE COMMANDS
APOGEE Intelligent Dashboard (AID)
APOGEE Intelligent Dashboard Is a standalone soft-ware to help owners manage their APOGEE Launch Monitor. The system includes diagnostic and automated calibration features to make identify-ing and solving any technical problems simple.
CALIBRATION
Launches the Automated Calibration Wizard (ACW). Enabling Calibration will
check installation alignment and adjust apertures for ambient light in the
area. The ACW guides APOGEE owners through any necessary next steps.
STATUS
See real-time status of network connections, the camera system, and the
internal temperature of your APOGEE Launch Monitor.
TOOLS
Manage APOGEE updates and personal preferences.
SUPPORT
View and Submit Logs to TruGolf Support Team.
Your contact information will be connected with these reports.
DOCUMENTATION
Collection of APOGEE documentation
STATUS
NETWORKING SYSTEM
- Internet Connection – connected/disconnected
- APOGEE Connection – connected/disconnected
CAMERA SYSTEM
- Center Camera- Online/offline status
- Offset Camera- Online/offline status
- Cooling System Fan 1 and Fan 2- Online/offline status
- Temperature- Lists the live internal temperature of the APOGEE device
TOOLS
SYSTEM TOOLS
- FIRMWARE UPDATE- Allows the user to update to the newest version of APOGEE firmware or revert to previous firmware version
- DEVICE RESTART- Reboots the APOGEE device
- RESET TO DEFAULTS- Resets APOGEE’s calibration settings to factory defaults
SYSTEM CONTROLS
- Laser Launchpad- Turn the Laser off/on
- APOGEE Voice Assistant- Turn the APOGEE Voice Assistant off/on
SUPPORT
SYSTEM LOG
- REFRESH FEED- Downloads and displays the latest logs from APOGEE
- SUBMIT TO TRUGOLF- Submits data logs to the TruGolf Support Team, making them available for review upon submission of a support ticket
- CLEAR LOGS- Clears the logs currently stored on your computer
SUPPORT INFORMATION
- REVIEW DOCUMENTATION- Opens the DOCUMENTATION section of the APOGEE CONTROL CENTER
- LAUNCH SUPPORT WEBSITE- Opens an internet browser and pulls up www.trugolf.com/support
CONTACT CUSTOMER SUPPORT
Monday–Friday • 9:00 am–5:00 pm MST
Toll Free: 877-711-6691 • Direct Line:
801-677-1123
https://trugolf.com/support
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>