PHILIPS BVP152 Smart Bright Flood Gen 3 Instruction Manual
- July 19, 2024
- Philips
Table of Contents
BVP152 Smart Bright Flood Gen 3
Specifications:
- Product: LED Floodlight
- Model: BVP152&BVP153 G3
- Version: V7.0
- Protection Rating: IK06 IP65
Product Usage Instructions:
1. Mounting the LED Floodlight:
To mount the LED floodlight, follow these steps:
-
Choose a suitable location for mounting the floodlight.
-
Securely attach the floodlight bracket to the desired surface
using appropriate screws and tools. -
Carefully place the LED floodlight onto the bracket and ensure
it is firmly in place.
2. Connecting the LED Floodlight:
After mounting the floodlight, follow these steps to connect
it:
-
Ensure the power source is turned off before making any
connections. -
Connect the wires from the floodlight to the power supply
following the manufacturer’s instructions. -
Double-check all connections to ensure they are secure and
properly insulated.
3. Adjusting the LED Floodlight:
Once the floodlight is mounted and connected, you can adjust its
position for optimal lighting coverage:
-
Use the adjustable brackets or pivoting mechanism to direct the
light where needed. -
Test the lighting direction and make necessary adjustments for
the desired illumination.
FAQ:
Q: What is the protection rating of this LED floodlight?
A: The protection rating of this LED floodlight
is IK06 IP65, indicating it is protected against dust and
low-pressure water jets.
LED Floodlight / LED / LED
BVP152&BVP153 G3
Mounting Instructions / /
V7.0
IK06 IP65
0m0<.X0<m5m
240V
Product Type /
BVP152 G3 LED9/830 10W 110-240V SWB BVP152 G3 LED10/865 10W 110-240V SWB
BVP152 G3 LED28/830 30W 110-240V SWB BVP152 G3 LED30/865 30W 110-240V SWB
BVP152 G3 LED47/830 50W 110-240V SWB BVP152 G3 LED50/865 50W 110-240V SWB
BVP153 G3 LED94/830 100W 110-240V SWB BVP153 G3 LED100/865 100W 110-240V SWB
BVP153 G3 LED141/830 150W 110-240V SWB BVP153 G3 LED150/865 150W 110-240V SWB
BVP153 G3 LED188/830 200W 110-240V SWB BVP153 G3 LED200/865 200W 110-240V SWB
CCT (K) /
3000 6500 3000 6500 3000 6500 3000 6500 3000 6500 3000 6500
Power(W) /
LEDs
10
28
30
56
50
84
100
168
150
252
200
336
Lumen Output (lm) /*
985 1050 2820 3000 4700 5000 9400 10000
14100 15000 18800 20000
(m² )
Surge rating /
Voltage /
Frequency /
0.006
0.194
0.02
0.516 1KV/2KV
0.025
0.652
0.06
1.508
110-130V~ 50/60Hz /220-240V~
0.09
2.528 2KV/4KV
0.12
2.97
10/30W ( ) 50/100/150/200W ()
Type A B C D a b c
10W 110 105 26 68 45 5 5.5
30W 190 156 27 120 100 6 6.5
50W 213 176 28 130 125 8.5 9
100W 323 254 34 200 160 8.5 9
150W 388 316 39 250 200 8.5 9
200W 455 356 39 290 210 10.5 11
:10W:300mm;30/50/100/150/200W:600mm
IP65 connector/IP65 not supplied with product
/
IP65 Junction Box/IP65 not supplied with product
/
7
50 36
10
Signify Taiwan Co., Ltd. Address : 2F-1, No. 508, Sec. 7, Zhongxiao E. Rd.,
Nangang Dist., Taipei City 115, Taiwan, R.O.C. /: : 5082 : 0800-808268 :
The terminal block should be complying with EN60998-2-1/EN60998-2-2 / EN60998-2-1/EN60998-2-2
H05RN-F 3×1.0 mm² 60245IEC57
N: L :
GND:-
IP65IP/. .
.IP68.
. /. .
1IJMJQTBOEUIF1IJMJQTTIJFMEFNCMFNBSFSFHJTUFSFEUSBEFNBSLTPG,POJOLMJKLF1IJMJQT/7
LED Floodlight / LED
BVP152&BVP153 G3
Mounting Instructions /
V7.0
Product Type /
BVP152 10W BVP152 30W BVP152 50W BVP153 100W BVP153 150W BVP153 200W
Run Current (A) / (A)
110V 0.095 0.29 0.47
1 1.38 1.85
230V 0.048 0.14 0.24 0.465 0.695 0.915
Start (Inrush) Current(A) /Ipeak (A)
/ (A)
230V <0.8 <2 <3 <6 <8 <10
Start Current Duration (s) /T(@50% of Ipeak) (s) /(s)
230V 100 100 100 100 100 100
- Touch current or protective conductor current (mA) /() (mA)
<3.5 <3.5 <3.5 <3.5 <3.5 <3.5
Maximum Number of Luminaire on MCB 16A Type B (pcs) /B16A
(pcs)
Maximum Number of Luminaire on MCB 16A Type C (pcs) /C16A
(pcs)
106
124
35
41
21
24
10
12
7
8
5
6
The leakage current (touch current or protective conductor current) of electrical circuit may be greatly dependent upon electrical supply cables used such as its rating and length, proper connection of electrical supply cables to luminaires and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions. In some cases referred to as Earth Leakage Current.
0-360°
Fasten the bolt
/
Torque : Nm Nm
10W
30W
(Nm)
2.5
2.5
50W 6
100W 10
150W 10
200W 17
no supplied with product /
Install the luminaire according to the national regulation and make sure it
will not fall off.
2× 10W/20W:M4 30W:M5 50W:M6 100W/150W:M8 200W:M10
Please read this manual carefully before using the product.
1. Do not switch on before complete installation. 2. The luminaire shall be
installed by a qualified electrician and wired in accordance with the latest
IEE electrical regulations or the national
requirements. 3. The external flexible cable or cord of this luminaire cannot
be replaced; if the cord is damaged, the luminaire shall be destroyed. 4. The
light source of this luminaire is not replaceable; when the light source
reaches its end of life the whole luminaire shall be replaced. 5. The
luminaire is complied with IEC60598. 6. Luminaire must not be used or stored
in corrosive environment where hazardous materials such as Sulphur, Chlorine,
phthalates, etc, are
present.
7. For content of restricted substances, please refer to the Signify website at https://www.smart-lighting.com.tw/RO HS Note: Please click the [RO HS Information] TAB under the [Support] list on the page
IEE
IEC60598
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>