ANTMINER KA3 Bitmain Server Instruction Manual
- June 2, 2024
- ANTMINER
Table of Contents
ANTMINER KA3 Bitmain Server
Copyright BITMAIN 2007 – 2022. All rights reserved. BITMAIN reserves the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to BITMAIN’s terms and conditions of sale supplied at the time of order acknowledgment.
BITMAIN warrants the performance of its products to the specifications applicable at the time of sale by BITMAIN’s standard warranty. Testing and other quality control techniques are used to the extent BITMAIN deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed.
BITMAIN assumes no liability for third-party application assistance. Customers are responsible for their products and applications using BITMAIN components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. BITMAIN does not warrant or represent that any license, either express or implied, is granted under any BITMAIN patent right, copyright or other BITMAIN intellectual property right relating to any combination, machine, or process in which BITMAIN products or services are used.
Information published by BITMAIN regarding third-party products or services does not constitute a license from BITMAIN to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from BITMAIN under the patents or other intellectual property of BITMAIN.
Resale of BITMAIN products or services with statements different from or beyond the parameters stated by BITMAIN for that product or service voids all express and implied warranties for the associated BITMAN product or service and is an unfair and deceptive business practice. BITMAIN is not responsible or liable for any such statements. All company and brand products and service names are trademarks or registered trademarks of their respective holders.
All text and figures included in this publication are the exclusive property
of BITMAIN, and may not be copied, reproduced, or used in any way without the
express written permission of BITMAIN. Information in this document is subject
to change without notice and does not represent a commitment on the part of
BITMAIN. Although the information in this document has been carefully
reviewed, BITMAIN does not warrant it to be free of errors or omissions.
BITMAIN reserves the right to make corrections, updates, revisions or changes
to the information in this document.
BITMAIN
Tel: +86-400-890-8855
www.BITMAIN.com
Overview
The KA3 server is BITMAIN’s newest version in this series. Power supply APW12 is part of the KA3 server. All KA3 servers are tested and configured before shipping to ensure easy set-up.
Caution
-
Please refer to the layout above to place your goods in usage in case of any damage.
-
The equipment must be connected to an earthed main socket outlet. The socket outlet shall be installed near theequipment and shall be easily accessible.
-
The equipment has two power inputs. Only by connecting those two power supply sockets simultaneously can
the equipment run normally. When the equipment is powered off, be sure to power off all power inputs. -
DO NOT remove any screws and cables tied to the product.
-
DO NOT PRESS the metal button on the cover.
-
Please note that the actual server shall prevail.
KA3 Server Components
The main components and controller front panel of KA3 servers are shown in the
following figure.
APW12 Power Supply
Note
- Power supply APW12 is part of the KA3 server. For detailed parameters, please refer to the specifications below.
- Additional two power cords are needed.
Specifications
- Model: KA3
- Hashrate: 166 TH/s
Product Glance | Value |
---|---|
Model | KA3 |
Crypto Algorithm/Coins | Blake2S |
Hashrate, TH/s | 166 ± 3% |
power on wall@25℃, Watt | 3154 ± 10% |
power efficiency on wall @ 25°C , J/TH | 19.0 ± 10% |
Detailed Characteristics | Value |
--- | --- |
Power Supply
Power supply AC input voltage, Volt (1-1)| 200~240
Power supply AC Input Frequency Range, Hz| 47~63
Power supply AC Input current, Amp (1-2)| 20 (1- 3)
Hardware Configuration
Network connection mode| RJ45 Ethernet 10/100M
Server Size (LengthWidthHeight, w/o package), mm (2-1)|
430195.5290
Server Size (LengthWidthHeight, with package), mm
| ****
570316430
Net weight, kg (2-2)| 16.1
Gross weight, kg| 17.7
Environment Requirements
Operation temperature, °C| 0~40
Storage temperature, °C| – 20~70
Operation humidity(non-condensing), RH| 10~90%
Operation altitude, m (3-1)| ≤2000
Notes
- (1-1) Caution: Wrong input voltage may probably cause Server damaged
- (1-2) Max condition: temperature 40°C, altitude 0m
- (1-3) Two AC input wires, 10A per wire
- (2-1) Including PSU size
- (2-2) Including PSU weight
- (3-1) When the Server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃foreveryincrease of 300m
Setting up the Server
To set up the server:
The file IPReporter.zip is supported by Microsoft Windows only.
-
Go to the following site: https://service.bitmain.com/support
-
Download the following file: IPReporter.zip.
-
Extract the file.
The default DHCP network protocol distributes IP addresses automatically. -
Right-click IPReporter.exe and run it as Administrator.
-
Select one of the following options:
- Shelf, Step, Position – suitable for farm servers to mark the location of the servers.
- Default – suitable for home servers.
-
Click Start. On the controller board, click the IP Report button. Hold it down until it beeps (about 5 seconds)
-
The IP address will be displayed in a window on your computer screen. In your web browser, enter the IP address provided.
-
Proceed to login using root for both the username and password.
-
In the Protocol section, you can assign a Static IP address (optional).
-
Enter the IP address, Subnet mask, gateway and DNS Server.
-
Click “Save”. 12. Click https://support.BITMAIN.com/hc/en-us/articles/360018950053 to learn more about the gateway and DNS Server.
Setting up the Server
Configuring the Server
Setting up the Pool
To configure the server:
Click Settings marked below.
Note
- Fan speed percentage can be adjusted, but we recommend keeping the default setting.
- The server will adjust the fan speed automatically if the fan speed percentage has yet been selected.
- There are two working modes of the KA3 server: Normal mode and Sleep mode.
- The server enters sleep mode under the condition that the control board is powered while the dashboards are not powered.
- ConfiguringtheServer3.
- Configuring the Server
Setting up the Pool
To configure the server:
- Click Settings marked below.
- Set the options according to the following table:
Option| Description
---|---
Mining address| Enter the address of your desired pool.
The KA3 servers can be set up with three mining pools, with decreasing priority from the first pool (pool 1) to the third pool (pool 3). The pools with low priority will only be used if all higher priority pools are offline.
Name| Your worker ID on the selected pool.
Password (optional)| The password for your selected worker.
3. Click Save after the configuration
Monitoring Your Server
To check the operating status of your server:
Click the dashboard marked below to check the server status (taking KA3 166T
as an example). Monitor your server according to the descriptions in the
following table:
Option | Description |
---|---|
Number of chips | Number of chips detected in the chain. |
Frequency | ASIC frequency setting. |
Real Hashrate | Real-time Hashrate of each hash board (GH/s). |
Inlet Temp | Temperature of the inlet (°C). |
Outlet Temp | Temperature of the outlet (°C). |
Chip state | One of the following statuses will appear: |
● The Green Icon – indicates normal
● The Red Icon – indicates abnormal
Note: The KA3 server (166T) has with fixed frequency of 665 MHz. Firmware
will stop running when the Temp(Outlet) reaches 80℃, there will be an error
message “over max temp, pcb temp (real-time temp)”
shown on the bottom of the kernel log page. Meanwhile, the server temperature
on the dashboard interface turns to abnormal and shows “Temp is too high”
Option | Description |
---|---|
Number of chips | Number of chips detected in the chain. |
Frequency | ASIC frequency setting. |
Real Hashrate | Real-time Hashrate of each hash board (GH/s). |
Inlet Temp | Temperature of the inlet (°C). |
Outlet Temp | Temperature of the outlet (°C). |
Chip state | One of the following statuses will appear: |
● The Green Icon – indicates normal
● The Red Icon – indicates abnormal
Administering Your Server
Checking Your Firmware Version
To check your firmware version
- Enter the backstage of your server, and find the firmware version on the bottom.
- Firmware Version displays the date of the firmware your server uses.
- In the examples below, the server is using firmware version 20220621.
Upgrading Your System
Make sure that the KA3 server remains powered during the upgrade process. If
power fails before the upgrade is completed, you will need to return it to
BITMAIN for repair
To upgrade the server’s firmware
In System, click Firmware Upgrade
For Keep Settings
- Select “keep settings” to keep your current settings (default).
- Unselect “keep settings” to reset the server to default settings.
- Click the button and navigate to the upgrade file. Select the upgrade file, then click Update.
- When the upgrade is completed, restart the server and it will turn to the settings page.
Modifying Your Password
To change your login password:
In the System, click the Password tab. Set your new password, then click Save.
Restoring Initial Settings
To restore your initial settings
- Turn on the server and let it run for 5 minutes.
- On the controller front panel, press and hold the Reset button for 10 seconds
- Resetting your server will reboot it and restore its default settings.
- The red LED will automatically flash once every 15 seconds if the reset is operated successfully.
Environmental Requirements
Please run your server by the following requirements
Basic Environmental Requirements
Climatic Conditions
Description | Requirement |
---|---|
Operating Temperature | 0-40℃ |
Operating Humidity | 10-90%RH (non-condensing) |
Storage Temperature | -20-70℃ |
Storage Humidity | 5-95%RH(non-condensing) |
Altitude | <2000m |
Site Requirements of the Server Running Room
- Please keep the server running room away from industrial pollution sources:
- For heavy pollution sources such as smelters and coal mines, the distance should be more than 5km.
- For moderate pollution sources such as chemical industries, rubber and electroplating industries, the distance should be more than 3.7km.
- For light pollution sources such as food factories and leather processing factories, the distance should be more than 2km.
- If unavoidable, the site should be chosen in the perennial upwind direction of the pollution source.
- Please do not set your location within 3.7km from the seaside or the salt lake. If unavoidable, it should be built as airtight as possible, and equipped with air conditioning for cooling.
Electromagnetic Environmental Conditions
Please keep your site away from transformers, high-voltage cables,
transmission lines and high-current equipment, for example, there should be no
high-power AC transformers (>10KA) within 20 meters, and no high-voltage power
lines within 50 meters. Please keep your site away from high-power radio
transmitters, for example, there should be no high-power radio transmitters
(>1500W) within 100 meters.
Other Environmental Requirements
The server running room shall be free of explosive, conductive, magnetically
conductive and corrosive dust. The requirements of mechanical active
substances are shown below:
Requirements of Mechanical Active Substances
Mechanical Active Substance | Requirement |
---|---|
Sand | <= 30mg/m3 |
Dust (suspended) | <= 0.2mg/m3 |
Dust (deposited) | <=1.5mg/m2h |
Requirements of Corrosive Gas
Corrosive Gas | Unit | Concentration |
---|---|---|
H2S | ppb | < 3 |
SO2 | ppb | < 10 |
Cl2 | ppb | < 1 |
NO2 | ppb | < 50 |
HF | ppb | < 1 |
NH3 | ppb | < 500 |
O3 | ppb | < 2 |
Note: ppb (part per billion) refers to the unit of concentration,1ppb stands for the volume ratio of part per billion.
Regulations
FCC Notice (FOR FCC CERTIFIED MODELS)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note
This equipment has been tested and found to comply with the limits for a Class
A digital device, under part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment
is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used by the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
EU WEEE: Disposal of Waste Equipment by Users in Private Households in the European Union This symbol on the product or its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>