Crane EE-3186 Adorables Ultrasonic Humidifiers INSTRUCTION MANUAL
- June 1, 2024
- Crane
Table of Contents
- Crane EE-3186 Adorables Ultrasonic Humidifiers
- IMPORTANT SAFETY INSTRUCTIONS
- LIST OF MAIN PARTS
- TECHNICAL SPECIFICATIONS
- BEFORE EACH USE
- ASSEMBLY & USE
- MAINTENANCE
- CRANE CUSTOMER CARE
- TROUBLESHOOTING
- CRANE WARRANTY
- FAQs
- Video- Crane EE-3186 Adorables Ultrasonic Humidifier
- Reference Link
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Crane EE-3186 Adorables Ultrasonic Humidifiers
IMPORTANT SAFETY INSTRUCTIONS
WARNING! READ AND SAVE THESE INSTRUCTIONS. Failure to follow all of the instructions listed below may result in electric shock, fire and/or serious personal injury.
- It is advisable to carry a filled Water Tank with two hands.
- DO NOT operate outdoors. This humidifier is intended for indoor use only.
- Always have water in the Water Tank when operating the unit.
- Use only clean, cool tap water to fill the Water Tank (filtered or distilled water is recommended to avoid white dust if tap water is too hard. DO NOT use hot water.
- Be sure that the Water Tank Cap is firmly tightened on the Water Tank. Always have the Mist Lid in place while the unit is operating. Place the humidifier so the mist aims away from children, walls, furniture and electrical appliances.
- Use only a 110-240VAC outlet.
- ALWAYS plug and unplug the unit with dry hands to avoid electric shock.
7. Never operate the unit with a damaged cord or plug.
8. Always place the unit on a smooth, flat, lint-free, non-metallic, waterproof, and level surface and position the unit away from direct sunlight. Keep the cord away from heated surfaces and areas where it could be walked on or tripped over. Unplug the unit when not in use and whenever you clean or move the unit.
9. Do not add medication of any type into the Water Basin or Water Tank. Do not cover any openings on the unit or insert objects into any openings.
10. The unit should not be left unattended in a closed room as the air could become saturated and leave condensation on walls or furniture. Leave room door partly open when humidifier is being operated.
11. When cleaning the inside of the humidifier, keep water away from the Fan Vent. Turn off and unplug the humidifier to wipe the exterior (except the electrical controls) with a damp cloth. Humidifier requires regular cleaning. Please refer to the CLEANING INSTRUCTIONS in this manual.
12. Do not tilt or tip the humidifier or attempt to empty or fill it while it is in operation.
13. Do not use a detergent to clean any parts of the unit that contain water. Detergent film dissolved in the water supply can interfere with the output of the unit. Instead, always use white vinegar mixed with water to clean the humidifier.
SAVE THESE INSTRUCTIONS!
GENERAL SAFETY INSTRUCTIONS
WARNING! Read and understand all instructions. Failure to follow all
instructions listed below may result in electric shock, fire, or serious
personal injury. The warnings, cautions, and instructions discussed in this
instruction manual cannot cover all possible conditions and situations that
may occur. It must be understood by the user that common sense and caution are
a factor that cannot be built into this product but must be supplied by the
user.
THIS HUMIDIFIER IS NOT A TOY!
Do not let your child play with this humidifier. Serious injury and
electrocution might be possible. This humidifier has to be operated by an
adult only. Children should be supervised to ensure that they do not play with
the humidifier.
SAVE ALL INSTRUCTIONS!
CAUTION: A short Power Supply Cord is provided to reduce the risk of
personal injury resulting from becoming entangled in or tripping over a longer
cord. Extension cords are available from local hardware stores and may be used
if care is exercised in their use. If an extension cord is required, special
care and caution are necessary. Also, the extension cord must be (1) marked
with an electrical rating of 125 V and at least 13 A., 1625 W., and (2) the
cord must be arranged so that it will not drape over the countertop or
tabletop where it can be pulled on by children or accidentally tripped over.
ELECTRIC POWER
If the electric circuit is overloaded by other appliances, your humidifier
and/or appliances may not operate properly. The humidifier should be operated
on a separate electrical circuit from other operating appliances.
POLARIZED PLUG
This humidifier has a polarized plug (one blade is wider than the other). As a
safety feature to reduce the risk of electrical shock, this plug is intended
to fit in a polarized outlet only one way. If the plug does not fit fully in
the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician. Do not attempt to defeat this safety feature.
SAFETY WARNING
Although your humidifier is easy to operate, for your safety, the below
warnings must be followed:
- Do not place the humidifier near a heat source.
- Never leave the humidifier unattended while connected to the electrical outlet.
- To avoid any accidents, never cover the Mist Lid when the humidifier is in operation.
- Use the humidifier on a smooth, flat, lint-free, non-metallic, waterproof, and level surface away from water.
- Do not unplug from the wall socket by pulling on the supply cord.
- The humidifier must be unplugged:
- A. Before either filling or emptying the Water Basin and/or Water Tank.
- B. Before any cleaning or maintenance is performed.
- C. After each use.
- D. If it appears to be faulty.
THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY.
LIST OF MAIN PARTS
Fig. 1 (Humidifier Base)
-
Nebulizer
-
Fan Outlet
-
Control Dial
-
Power Indicator Lights
-
Water Level Sensor Fig. 2 (Bottom of Water Tank)
-
Mist Outlet Channel
-
Water Tank Cap
Fig. 3 (Mist Lid) -
Mist Output Slot (Location may differ based on your model)
TECHNICAL SPECIFICATIONS
- Rating Voltage: 110-240V
- Wattage: 24W
- Frequency: 50/60Hz
- Water Tank Capacity: Approx. 1 Gallon / 3.78 Liter
- Run Time Per Tank: Up to 24 hours
- Humidifying Capacity: Up to 250 sq. ft. / 23m2
- Noise Level: < 37 decibels from 3 ft away
BEFORE EACH USE
CHECK HUMIDIFIER PLACEMENT:
Place the Humidifier on an elevated, non-metallic, lint-free, waterproof,
level surface at least 2 feet above the floor.
- DO NOT PLACE ON CARPET OR TOWEL. The fan vent is located on the bottom of the humidifier base. The fan vent MUST NOT be obstructed.
- DO NOT PLACE ON WOOD SURFACE or near furniture that can be damaged by too much moisture.
CHECK WATER LEVEL SENSOR:
Make sure the Water Level Sensor is secured properly and not obstructed. (Page
4 – Fig. 1)
CAUTION
- DO NOT attempt to operate the humidifier without water in the Water Tank.
- DO NOT plug or unplug the Power Cord with wet hands as an electric shock could occur.
ASSEMBLY & USE
ALWAYS use fresh cool water when operating the humidifier.
-
Turn the Water Tank upside down, unscrew the Water Tank Cap and fill with cool water only.
NOTE: Filtered or distilled water is recommended to avoid white dust if tap water is too hard
ALWAYS HOLD WATER TANK WITH TWO HANDS WHEN FULL.- DO NOT fill water to the rim.
- DO NOT use hot water.
- DO NOT add any medication, essential oils, or salt.
- DO NOT pour water into the Mist Lid.
-
Screw the Water Tank Cap back onto Water Tank and turn the tank over to place it on Humidifier Base, making sure it fits together securely.
Note : Do not attempt to move the humidifier while full Water Tank is placed on the Humidifier Base. Doing so may cause leakage of water and/or Humidifier Base to overfill. -
Plug the power cord into a wall socket and turn on the unit by using the Control Dial.
-
The green Power Indicator Light will illuminate indicating that there is enough water in the Humidifier Base and mist will begin emitting through the Mist Lid.
-
Use the Control Dial to adjust the intensity of the mist output.
SET THE CORRECT HUMIDITY OUTPUT : Adjust the Control Dial so the mist rises up to be absorbed by the room air. If the mist drops quickly, turn down the control knob until the mist is rising up. -
When the humidifier runs out of water, the red Power Indicator Light will illuminate and the mist output will stop. This is a safety feature to prevent the humidifier frompossibly overheating and damaging the Nebulizer. Turn the humidifier off and unplug the unit before removing and refilling the water tank. When emptying the base, be sure to pour away from the fan outlet.
A NOTE ABOUT HUMIDITY
- To reduce excessive humidity or condensation, especially in small rooms, leave the room door open and adjust mist intensity to the low output setting.
- Too much humidity in the room may allow moisture to accumulate on surfaces where bacteria and fungi can grow. Moisture that gathers may also damage furniture and walls, especially wallpaper.
MAINTENANCE
Cleaning and disinfecting regularly is important for maintaining the
performance of your humidifier.
IMPORTANT: Water left in the tank or base when not in use may result in a
buildup of mineral deposits and bacteria which may inhibit the output
efficiency as well as void the warranty. If water remains in the Water Tank
for more than a day or two, bacterial growth is possible.
DAILY MAINTENANCE
- Turn off, unplug from outlet and empty water from tank & base daily.
- Allow tank & base to air dry.
- Leave cap off the tank until ready for next use.
WEEKLY MAINTENANCE
-
Turn off, unplug from outlet and empty water from tank & base.
-
Fill the water tank halfway warm water and add 2 Tablespoons of white vinegar.
Shake vigorously and let sit for 30 minutes. Empty tank and rinse with plain water. -
Fill base with warm water, add 1 tablespoon of white vinegar and let sit for 30 min. Empty base & rinse with plain water. Make sure to pour water away from the fan outlet when emptying.
TIP: Clean the nebulizer with a damp cloth or cotton swab after soaking. -
Allow tank & base to air dry and leave cap off the tank until the next use. NEVER IMMERSE THE HUMIDIFIER BASE IN WATER.
END-OF-SEASON MAINTENANCE & STORING YOUR HUMIDIFIER
- Turn off, unplug from outlet, and empty water from tank & base.
- Follow instructions for weekly maintenance above.
- Let all parts dry completely.
- Store humidifier in a cool, dry place.
CRANE CUSTOMER CARE
- CALL US: 888-599-0992 (Mon-Fri 9:00am – 4:00pm CST)
- EMAIL US: customer-service@crane-usa.com
- LIVE CHAT: available at www.crane-usa.com
TROUBLESHOOTING
DO NOT attempt to repair the motor yourself.
If the humidifier continues to not operate, please contact Crane Customer
Care.
Problem | Solution |
---|
Indicator Light is Staying Red:
| ****
§ Ensure the cap is secured properly to the tank allowing water to pass through to the base.
§ Clean the Water Level Sensor: Pull of the plastic cap from the peg. Remove the water level sensor float and clean with warm sudsy water. Replace parts by first putting the float onto the peg, then replacing the plastic cap on the peg. (Page 4 – Fig. 1)
Humidifier Does Not Have Any Power:
| § Ensure unit is properly plugged into a power outlet / try another power outlet.
§ Check the Control Knob is turned to the ON position.
§ If Power On indicator light does not come on, contact Customer Care.
There is a Strange Odor:
| § Clean the Water Tank with a water & white vinegar solution and rinse with clean water. (Page 7)
§ Leave the empty Water Tank open in a cool place for 12 hours without the Water Tank Cap attached.
Indicator Light is
Green, But There’s No
Mist:
| § Complete the weekly maintenance. (Page 7)
§ The base might be overfilled: Remove the tank, empty the base & replace the filled tank on the empty base.
§ Humidifier should be placed on a hard flat surface & fan vent should not be blocked.
§ Try turning the control knob up to MAX and let it run for 10 minutes.
White Dust Appears & Settles Outside the Humidifier:| § Area tap water may have too many minerals. Change to filtered or distilled water, or use with a Crane Demineralization Filter cartridge.
Humidifier is Leaking:
| § From MIST LID: Turn control knob down
§ From TANK: Check for possible cracks in the tank or around the seam
§ From BASE: Call Customer Care
NOTE: Spare Parts can also be purchased online at www.crane- usa.com
CRANE WARRANTY
For more information regarding the warranty policy, please visit our website: www.crane-usa.com/customer-service
LIMITED WARRANTY
Thank you for purchasing a Crane product that has been tested to meet our
stringent quality standards. This product is warrantied to be free from
manufacturing defects under normal use and conditions for 1 year.
PLEASE CONTACT US BEFORE RETURNING THIS PRODUCT TO THE STORE. CALL CRANE
CUSTOMER CARE FOR PROBLEMS AND QUESTIONS. WE CAN HELP. THE WARRANTY REQUIRES A
DATED PROOF OF PURCHASE.
This warranty is void if the defect is due to accidental damage, misuse,
abuse, neglect, improper repair or alteration by unauthorized persons, or a
failure to follow operating instructions provided with the product including
the use of essential oils directly into the tank and base. This warranty does
not apply to normal wear and tear or commercial use.
In no event shall liability exceed the purchase price paid by the purchaser of
the product. Under no circumstances shall there be liability for any loss –
direct, indirect or incidental – or consequential damage arising out of, or in
connection with the use of this product. This warranty is valid only in the 48
contiguous states plus the District of Columbia and excludes Puerto Rico and
the Virgin Islands. This warranty is effective only if the product is
purchased and operated in the United States of America.
Any instructions or warranty included in this manual may be subject to change
without notice. For the Please contact us or visit our website for the most
up-to-date instructions and warranty information. TO RECEIVE WARRANTY
INSTRUCTIONS AND RETURN AUTHORIZATION, PLEASE CALL OR EMAIL CRANE CUSTOMER
CARE. CRANE USA, INC.
- 1015 Hawthorn Dr., Itasca, IL 60143
- Toll-Free: 1-888-599-0992 (Monday – Friday 9:00am – 4:00pm CST)
- Email: customer-service@crane-usa.com
- Website: www.crane-usa.com
FAQs
What is the capacity of the Crane EE-3186 Adorables Ultrasonic Humidifier?
The Crane EE-3186 Adorables Ultrasonic Humidifier has a 1-gallon capacity.
How long does the demineralization humidifier filter for the Crane EE-3186 last?
Each demineralization humidifier filter for the Crane EE-3186 lasts for 30-40 tank fills.
What is the coverage area of the Crane EE-3186 Adorables Ultrasonic Humidifier?
The Crane EE-3186 Adorables Ultrasonic Humidifier provides coverage for up to 500 square feet.
What technology is used in the Crane EE-3186 Adorables Ultrasonic Humidifier for mist production?
The Crane EE-3186 Adorables Ultrasonic Humidifier uses ultrasonic technology for mist production.
How long does the Crane EE-3186 Adorables Ultrasonic Humidifier provide soothing moisture?
The Crane EE-3186 Adorables Ultrasonic Humidifier provides 24 hours of soothing moisture.
Which models are compatible with the demineralization filter for the Crane EE-3186?
The demineralization filter is compatible with Crane Drops, Droplets, and EE-5202 warm mists, including the EE-3186 model.
What is the purpose of the clean control anti-microbial material used in the humidifier filter for the Crane EE-3186?
The clean control anti-microbial material in the filter reduces mold and bacteria growth by up to 99.96% in the Crane EE-3186.
How can the Crane EE-3186 Adorables Ultrasonic Humidifier help relieve the effects of dry air?
The Crane EE-3186 Adorables Ultrasonic Humidifier provides soothing moisture to help relieve the effects of dry air.
What are the color options available for the Crane EE-3186 Adorables Ultrasonic Humidifier?
The Crane EE-3186 Adorables Ultrasonic Humidifier is available in White, Blue, and Pink color options.
What is the mist output capacity of the Crane EE-3186 Adorables Ultrasonic Humidifier?
The mist output of the Crane EE-3186 Adorables Ultrasonic Humidifier is perfect for humidifying rooms up to 500 square feet.
What are the key features of the Crane EE-3186 Adorables Ultrasonic Humidifier?
The key features of the Crane EE-3186 Adorables Ultrasonic Humidifier include cute animal designs, adjustable mist control, auto-off function, and easy-to- clean design.
What is the warranty period for the Crane EE-3186 Adorables Ultrasonic Humidifier?
The warranty period for the Crane EE-3186 Adorables Ultrasonic Humidifier is 1 year.
Video- Crane EE-3186 Adorables Ultrasonic Humidifier
Download this Manual:Crane EE-3186 Adorables Ultrasonic Humidifiers INSTRUCTION MANUAL
Reference Link
Crane EE-3186 Adorables Ultrasonic Humidifiers INSTRUCTION MANUAL- DEVICE.REPORT
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>