Features
2 pole EURO plug , Class Ⅱ power unit
- Medical safety approved (2 × MOPP) according to EN60601-1/-1-11
- Extremely low leakage current
- No load power consumption<0.1W
- Energy efficiency Level
- Ⅵ and meet CoC version 5
- ( except 5~9V for Level Ⅴ)
Applications
- Blood glucose meter
- Blood pressure meter
- Nebulizer
- Inhaler
- Portable medical device
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
GSM18E is a highly reliable, 18W wall-mounted style single-output green
medical adaptor series. This product is equipped with a 2-pin (no FG) standard
European power plug, adopting the input range from 80VAC to 264VAC. The entire
series supplies different output voltages between 5VDC and 48VDC that can
satisfy the demands for various kinds of miniature medical devices. The
circuitry design meets the international medical standards (2 × MOPP), having
an ultra low leakage current (<50μA), fitting the medical devices in direct
electrical contact with the patients.
With the efficiency up to 88% and the extreme low no-load power consumption
below 0.1W, GSM18E is compliant with EU ErP and meet Code of Conduct(CoC)
Version 5; the supreme feature allows the adaptor to save the energy when it
is either under the operating mode or the standby mode. The entire series
utilizes the 94V-0 flame retardant plastic case, providing the double
insulation that effectively prevents electrical shock. GSM18E is approved with
the international medical safety certificates.
Model Encoding
SPECIFICATION
ORDER NO.| GSM
18E05- P1J| GSM1
8E07
– P1J| GSM1
8E09
– P1J| GSM1
8E1
2- P1J| GSM1
8E15
– P1J| GSM1
8E1
8- P1J| GSM1
8E2
4- P1J| GSM
18E48- P1J
---|---|---|---|---|---|---|---|---
OUTPUT
| SAFETY MODEL NO.| GSM18E05| GSM18E07| GSM18E09| GSM18E12|
GSM18E15| GSM18E18| GSM18E24| GSM18E48
DC VOLTAGE **Note.2| 5V| 7.5V| 9V| 12V| 15V| 18V| 24V| 48V
RATED CURRENT| 3A| 2A| 2A| 1.5A| 1.2A| 1A| 0.75A| 0.375A
CURRENT RANGE| 0 ~ 3A| 0 ~ 2A| 0 ~ 2A| 0 ~ 1.5A| 0 ~ 1.2A| 0 ~ 1A| 0
~ 0.75A| 0 ~ 0.375A
RATED POWER (max.)| 15W| 15W| 18W| 18W| 18W| 18W| 18W| 18W
RIPPLE & NOISE (max.) Note.3| 60mVp-p| 80mVp-p| 80mVp-p|
120mVp-p| 120mVp-p| 150mVp-p| 180mVp-p| 240mVp-p
VOLTAGE TOLERANCE Note.4| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%|
±3.0%| ±2.0%| ±2.0%
LINE REGULATION ****Note.5| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±5.0%| ±5.0%| ±5.0%| ±3.0%| ±3.0%| ±3.0%| ±2.0%|
±2.0%
SETUP, RISE TIME ****Note.6| 500ms, 30ms / 230VAC
1000ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)**| 16ms / 230VAC 16ms / 115VAC at
full load
INPUT
| VOLTAGE RANGE **Note.7| 80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 80%| 83%| 84%| 85%| 85.5%| 86%| 87%| 88%
AC CURRENT (Typ.)| 0.5A / 115VAC 0.25A / 230VAC
INRUSH CURRENT (Typ.)| 55A / 230VAC 30A / 115VAC
LEAKAGE CURRENT(max.)**| Touch current < 50μA/264VAC
PROTECTION
| OVERLOAD| 105 ~ 170% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE| 5.25 ~ 7.5V| 7.88 ~ 10.13V| 9.45 ~ 12.6V| 12.6 ~
17.2V| 15.75 ~ 20.25V| 18.9 ~ 24.3V| 25.2 ~ 32.4V| 50.4 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| -25 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03% / ℃ (0~40℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC
(Note. 8)
| SAFETY STANDARDS| TUV EN60601-1 / EN60601-1-11, EAC TP TC 004
approved
ISOLATION LEVEL| Primary-Secondary: 2xMOPP
WITHSTAND VOLTAGE| I/P-O/P:4KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted emission| EN55011 (CISPR11)| Class B
Radiated emission| EN55011 (CISPR11)| Class B
Harmonic current| EN61000-3-2| Class A
Voltage flicker| EN61000-3-3| —–
EMC IMMUNITY
| EN60601-1-2, EN61204-3
Parameter| Standard| Test Level / Note
ESD| EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| EN61000-4-3| Level 3, 10V/m( 80MHz~2.7GHz ) Table 9,
9~28V/m( 385MHz~5.78GHz )
EFT bursts| EN61000-4-4| Level 3, 2KV
Surge susceptibility| EN61000-4-5| Level 3, 1KV/Line-Line
Conducted susceptibility| EN61000-4-6| Level 3, 10V
Magnetic field immunity| EN61000-4-8| Level 4, 30A/m
Voltage dip, interruption| EN61000-4-11| 100% dip 1 periods, 30% dip 25
periods,
100% interruptions 250 periods
OTHERS
| MTBF| 3888.9K hrs min. Telcordia SR-332 (Bellcore) ; 794.6K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 795433mm (LWH)
PACKING| 200g ; 60pcs / 13Kg / CARTON
CONNECTOR| PLUG| See page 4~5 ; Other type available by customer
requested
CABLE| See page 4~5 ; Other type available by customer requested
NOTE
| 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12″ twisted pair terminated with a 0.1μF & 47μF capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Derating Curve
Static Characteristics
Mechanical Specification
DC output plug
Standard plug: P1J
DC plug changeable through:
- Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
- Quick adapter accessory (sold separately without MOQ)
- Please refer to below table and online selection guide : https://www.meanwell.com/upload/pdf/DC_plug.pdf
Example quick adapter accessory
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>