Safety Information
Read the following installation instructions carefully before installing,
powering, or operating the device.
WARNING! THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED
ATTENTION! CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT
AINSI QUE LES RISQUES INHÉRENTS
IP67 “SUITABLE FOR WET LOCATIONS” “CONVIENTAUX EMPLACEMENTS MOUILLÉS”
Accessory Information
Stacking order
-
Nylon Insert Lock Nut (provided)
P/N: 002.11.0985.04 -
Urban Lux Rock Guard
-
Urban Lux Egg Crate or Urban Lux Louver
-
Urban Lux Filter Frame
-
Urban Lux Top Hat or Urban Lux Half Hat
-
HEX Socket Set Screw (provided)
P/N: 002.14.0913.0430 -
HEX Socket Head Cap Screw (provided)
P/N: 002.12.0912.0410 -
Urban Lux 1X… luminaire
Remove all ❼ using 3 mm HEX tool before adding accessories.
Accessories can be installed individually or in various combinations Any
accessory configuration should be secured with all ❶ and ❻ using 2 mm HEX tool
and 7 mm wrench (customer supplied).
Torque specification: 2.2 Nm – 2.8 Nm
Mounting Information
Mounting combinations
Mounting attachment
Any mounting type must be attached to luminaire with HEX Fixing Screws (M4)
provided in the mounting kit using 3 mm HEX tool (customer supplied). Torque
specification: 2.2 Nm – 2.8 Nm
BACK side of luminaire
Mounting types A
Fixed Mount 180deg Included in the kit: 2x Mounting part
8x Fixing Screw (M4)
Fixed Mount 90deg Included in the kit: 2x Mounting part
8x Fixing Screw (M4)
Universal Adjustable Mount Included in the kit: 2x Mounting part
8x Fixing Screw (M4)
Included in the kit: 2x Mounting part
4x Fixing Screw, washer, and nut (M6)
2x Fixing Screw, washer, and nut (M12)
Can be combined with
Included in the kit:
2x Mounting part
4x Fixing Screw, washer, and nut (M6)
2x Fixing Screw, washer, and nut (M12)
Mounting types B
_ **Adjustable Yoke 1×4
Adjustable Yoke 1×8
Adjustable Yoke 1×16
**_
Included in the kit:
1x Mounting part
8x Fixing Screw (M4)
Can be combined with
2” Pole Adapter
4” Pole Adapter
Included in the kit:
1x Mounting part
2x Fixing Screw, washers, and nut (M12)
INSTALLATION INSTRUCTION
Dimensions and mounting information
Fasten the unit to a well-ventilated area using four M4 screws through
the molded-on flanges. Torque the screws within the range of 2.2 Nm to 2.8
Nm.
Mounting on DIN Rail
In case of installation on a DIN rail, ensure the use of the provided DIN
mounting plate.
The unit should be secured to a mounting plate using four M4 screws through
the molded-on flanges. The torque specification for these screws is between
2.2 Nm and 2.8 Nm.
Please ensure proper ventilation if mounted in a closed-type installation box.
Wiring information
Connecting Power
WARNING! For protection from electric shock, the fixture must be
electrically connected to ground (earth). The AC mains power supply must be
fitted with a fuse or circuit breaker of 13A MAX and ground-fault (earth-
fault) protection.
WARNING! DOP Injector require UrbanLux luminaires to operate.
DOP Injector must be installed by a qualified electrician in accordance with
all national and local electrical and construction codes and regulations
DANGER!
Risk of electric shock. Do not open the device.
Always power off the fixture before mounting/removing accessories or
dismantling the product.
Ensure that the mains power is cut off when wiring the device or connecting to
a luminaire.
Ensure that the device is electrically connected to earth (ground).
Do not apply power if the device or cables are damaged.
Do not immerse the fixture in water or liquid.
Connecting Power
Connecting to LINE use Circuit Breaker or Fuse rated at 13A MAX !
Never exceed allowed amount of Urban Lux fixtures per DOP Injector Output
Urban Lux Fixtures Per DoP Injector
Fixture| 1×1| 1×4| 1×8| 1×16| 2×2| 2×5| 2×10| 2×15
Max units @| 120V| 30| 30| 8| 30| 15| 5| 8 16
Max units @240V| 30| 30| 30| 15| 30| 15| 15| 10
Max units @277V| 26| 26| 26| 13| 13| 26| 13| 8
Total System Inrush <40A, with
DoP Injector
*Never exceed allowed amount of Urban Lux fixtures per DoP Injector output
Connecting DMX
DOP Injector has two 3-pin PTB sockets with removable plugs for DMX/RDM input and output.
DMX pinout:
Connect DMX data output from the controller to the DOP Injector DMX In PTB
plug using screws.
Run the data link from the DOP Injector DMX Thru socket to the DMX In of the
next unit.
Terminate data link by connecting a 120 Ohm resistor between +Data and
-Data at the DMX Thru of the last unit in DMX line.
Technical Specs
Physical
Length| 180 mm [7.1 inch]
Width| 91 mm [3.6 inch]
Height| 67 mm [2.6 inch]
Color| TBA
Enclosure| Impact-resistant polycarbonate
Mounting| to surface with 4 x M4 screws
Connections
DMX/RDM| PTB pluggable terminal block (30 to 14AWG)
Power In| screwdriver-actuated CAGE CLAMP® connection
(28 to 12AWG)
UrbanLux Output| screwdriver-actuated CAGE CLAMP® connection (28 to 12AWG)
Control
DMX| Yes
RDM| Yes
Art-Net| No
sACN| No
Addressing| via RDM
Firmware update| via DMX link
Electrical
Voltage Input| 100VAC to 277VAV ( 50 / 60 Hz )
Power consumption| 1300W max @ 100VAC 1560W max @ 120VAC 3120W max @ 240VAC
3600W max @ 277VAC
Inrush current| <40A
Fuse| external 13A max (not provided)
Environment
Operating temperature| -25°C to 50°C [-4°F to +122°F]
Protection rating| IP30