SOLARIS Flare LR Q+ Strobe and Blinder Lighting User Guide

June 6, 2024
SOLARIS

SOLARIS Flare LR Q+ Strobe and Blinder Lighting User Guide
SOLARIS Flare LR Q+ Strobe and Blinder Lighting

SETUP

SAFETY INSTRUCTIONS

Please read these instructions carefully. This user guide contains important information about the installation, usage, and maintenance of this product

  • Keep this Quick Start Guide for future reference. If unit is sold to another user, make sure they also receive this instruction booklet.
  • Ensure the unit is connected to proper voltage, and that line voltage is not higher than that stated on the device.
  • Make sure there are no flammable materials close to the unit while operating.
  • Always disconnect from the power source before servicing or fuse replacement. Always use the fuse specified in this manual.
  • Maximum ambient temperature (Ta) is 40°C (104°F). Do not operate unit at temperatures above this rating.
  • In the event of a serious operating problem, stop using the unit immediately. Repairs must be carried out by trained, authorized personnel. Contact the nearest authorized technical assistance center. Only OEM spare  parts should be used.
  • Do not connect the device to a dimmer pack.
  • Make sure power cord is never crimped or damaged.
  • Never disconnect power cord by pulling or tugging on the cord.

Caution! There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your distributor.

UNPACKING INSTRUCTIONS

Upon receipt of the unit, carefully unpack the carton and check the contents to ensure that all parts are present and in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear to be damaged from shipping or if the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a unit must be returned to the factory, it is important that it be returned in the original factory box and packing.

POWER REQUIREMENTS

Before powering the unit, make sure the line voltage is within the range of accepted voltages. This unit accommodates 100-240VAC, 50/60Hz. All units must be powered directly from a switched circuit and cannot be operated with a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0-100% switch.

RIGGING SOLARIS FLARE Q+ LR

Always consult a certified rigging specialist before suspending any device overhead.

Solaris Flare Q+ LR weighs approx. 24.3 lbs (11 kg) and requires multiple attachment points for safety. Use ProBurger® couplers or equivalent C- or O-type clamps for attaching to truss, rated for fixture weight. After establishing the desired position, tighten all appropriate bolts.

  • Always use safety cables!
  • When selecting installation location, consider routine maintenance.
  • Team lift the fixture into mounting location, never try to mount fixture with one person.
  • Never mount fixture where it will be exposed to excess moisture, high humidity, extreme temperatures, or restricted ventilation for long periods of time
    RIGGING SOLARIS FLARE Q+ LR

SOLARIS FLARE Q+ LR ATTACHABLE FEET

Solaris Flare Q+ LR has optional feet attachments which allow for floor mounting applications. The PreSet™ Yoke automatically snaps to 15° increments from -45° to +135° for ease of use and focusing.
SOLARIS FLARE Q+ LR ATTACHABLE FEET

The default menu display shows the current DMX address, mode and footprint, as well as the option to rotate the screen and enter further menu options. Four control panel buttons are located near each corner of the LCD Display.
NAVIGATION OVERVIEW

Press and hold the < MENU> button to scroll through the top-level menu items. Use the and buttons, located to the right of the LCD screen, to navigate the menu map and menu options. Press the < ✔ > button to access the menu function currently displayed or to enable a menu option. To return to the top of the menu map or menu without changing the value, press the **< X

** button.
NAVIGATION OVERVIEW

MENU MAP

FLARE Q+ LR PIXEL MAP

Solaris Flare Q+ LR feature 108 10W Cree LEDs located in 3 rows and 36 columns.

The LEDs have multiple options of control, subdivided into different “pixel” quantities. In Advanced Control Modes the Flare Q+ LR has the additional function of selecting a desired pixel group.

LEDs are grouped into the following pixel options:

  • 1-pixel unit – 1 group of 108 LEDs
  • 2-pixel unit – 2 groups of 54 LEDs
  • 3-pixel unit – 3 groups of 36 LEDs
  • 4-pixel unit – 4 groups of 27 LEDs
  • 6-pixel unit – 6 groups of 18 LEDs
  • 12-pixel unit – 12 groups of 9 LEDs
    FLARE Q+ LR PIXEL MAP

Note! Each mode can be inverted when last pixel becomes the first.

BASIC CONTROL MODES

Basic control modes for RGB and RGBW control the Flare Q+ LR as 1-pixel mode for color wash applications.

Mode Channel DMX values Preset Function

RGB

8bit

| 1| 0 – 255| 0 – 100| Red Intensity
2| 0 – 255| 0 – 100| Green Intensity
3| 0 – 255| 0 – 100| Blue Intensity

RGB

16bit

| 1| 0 – 255| 0 – 100| Red Intensity HI Byte
2| 0 – 255| 0 – 100| Red Intensity LOW Byte
3| 0 – 255| 0 – 100| Green Intensity HI Byte
4| 0 – 255| 0 – 100| Green Intensity LOW Byte
5| 0 – 255| 0 – 100| Blue Intensity HI Byte
6| 0 – 255| 0 – 100| Blue Intensity LOW Byte
Mode| Channel| DMX values| Preset| Function
---|---|---|---|---

RGBW

8bit

| 1| 0 – 255| 0 – 100| Red Intensity
2| 0 – 255| 0 – 100| Green Intensity
3| 0 – 255| 0 – 100| Blue Intensity
4| 0 – 255| 0 – 100| White Intensity

RGBW

16bit

| 1| 0 – 255| 0 – 100| Red Intensity HI Byte
2| 0 – 255| 0 – 100| Red Intensity LOW Byte
3| 0 – 255| 0 – 100| Green Intensity HI Byte
4| 0 – 255| 0 – 100| Green Intensity LOW Byte
5| 0 – 255| 0 – 100| Blue Intensity HI Byte
6| 0 – 255| 0 – 100| Blue Intensity LOW Byte
7| 0 – 255| 0 – 100| White Intensity HI Byte
8| 0 – 255| 0 – 100| White Intensity LOW Byte

STROBE MODES

Strobe Only Mode

| 1| 0 – 255| 0 – 100| Strobe Intensity
---|---|---|---|---
2| 0 – 255| 0 – 100| Strobe Duration
3| 0 – 255| 0 – 100| Strobe Rate
4| 0 – 255| 0 – 100| Strobe FX

Strobe Value Breakdown:

DMX Value DMX Percent Strobe Intensity
0 – 5 0 – 2 Blackout
6 – 255 3 – 100 Intensity level
    Strobe Duration
0 – 254 0 – 99 0 – 650ms (50Hz AC)
255 100 HYPER
    Strobe Rate
0 – 5 0 – 2 No flash
6 – 255 3 – 100 0.5 – 25Hz (50Hz AC); 0.6 – 30Hz (60Hz AC)
    Strobe effects
0 – 4 0 – 2 No effect
5 3 Wash Override (only available in RGB Strobe and RGBW Strobe modes) 1
6 – 42 4 -16 Ramp up
43 – 85 17 – 33 Ramp down
86 – 128 34 – 50 Ramp up – down
129 – 171 51 – 67 Random
172 – 214 68 – 84 Lighting
215 – 240 85 – 92 Spikes
241 – 245 93 – 95 Burst (use Rate at full) 2
246 – 250 96 – 98 “Meltdown” Random Pixels w/ Solid Background 3
251 – 255 99 – 100 “Meltdown” Random Pixels w/ Burst Background4
Mode Channel DMX Value
--- --- ---

RGB

Strobe

| 1| 0 – 255| 0 – 100| Red Strobe Intensity
2| 0 – 255| 0 – 100| Green Strobe Intensity
3| 0 – 255| 0 – 100| Blue Strobe Intensity
4| 0 – 255| 0 – 100| Strobe Intensity
5| 0 – 255| 0 – 100| Strobe Duration
6| 0 – 255| 0 – 100| Strobe Rate
7| 0 – 255| 0 – 100| Strobe FX

RGBW

Strobe

| 1| 0 – 255| 0 – 100| Red Strobe Intensity
2| 0 – 255| 0 – 100| Green Strobe Intensity
3| 0 – 255| 0 – 100| Blue Strobe Intensity
4| 0 – 255| 0 – 100| White Strobe Intensity
5| 0 – 255| 0 – 100| Strobe Intensity
6| 0 – 255| 0 – 100| Strobe Duration
7| 0 – 255| 0 – 100| Strobe Rate
8| 0 – 255| 0 – 100| Strobe FX

ADVANCED RGB STROBE MODES

RGBW PIXEL MODE 11 RGBW PIXEL MODE 213 RGBW PIXEL MODE 317 RGBW PIXEL MODE 421 RGBW PIXEL MODE 625       RGBW PIXEL MODE 1233

PIXEL MODE CHANNEL DMX VALUE PERCENT FUNCTION
RGB PIXEL MODE 1 1 0 – 255 0 – 100 Red Strobe Intensity
2 0 – 255 0 – 100 Green Strobe Intensity
3 0 – 255 0 – 100 Blue Strobe Intensity
4 0 – 255 0 – 100 Strobe Intensity
5 0 – 255 0 – 100 Strobe Duration
6 0 – 255 0 – 100 Strobe Rate
7 0 – 255 0 – 100 Strobe FX
8 0 – 255 0 – 100 1 pix Red intensity
9 0 – 255 0 – 100 1 pix Green intensity
10 0 – 255 0 – 100 1 pix Blue intensity
RGB PIXEL MODE 2 11 0 – 255 0 – 100 2 pix Red intensity
12 0 – 255 0 – 100 2 pix Green intensity
13 0 – 255 0 – 100 2 pix Blue intensity
RGB PIXEL MODE 3 14 0 – 255 0 – 100 3 pix Red intensity
15 0 – 255 0 – 100 3 pix Green intensity
16 0 – 255 0 – 100 3 pix Blue intensity
RGB PIXEL MODE 4 17 0 – 255 0 – 100 4 pix Red intensity
18 0 – 255 0 – 100 4 pix Green intensity
19 0 – 255 0 – 100 4 pix Blue intensity
RGB PIXEL MODE 6 20 0 – 255 0 – 100 5 pix Red intensity
21 0 – 255 0 – 100 5 pix Green intensity
22 0 – 255 0 – 100 5 pix Blue intensity
23 0 – 255 0 – 100 6 pix Red intensity
24 0 – 255 0 – 100 6 pix Green intensity
25 0 – 255 0 – 100 6 pix Blue intensity
RGB PIXEL MODE 12 26 0 – 255 0 – 100 7 pix Red intensity
27 0 – 255 0 – 100 7 pix Green intensity
28 0 – 255 0 – 100 7 pix Blue intensity
29 0 – 255 0 – 100 8 pix Red intensity
30 0 – 255 0 – 100 8 pix Green intensity
31 0 – 255 0 – 100 8 pix Blue intensity
32 0 – 255 0 – 100 9 pix Red intensity
33 0 – 255 0 – 100 9 pix Green intensity
34 0 – 255 0 – 100 9 pix Blue intensity
35 0 – 255 0 – 100 10 pix Red intensity
36 0 – 255 0 – 100 10 pix Green intensity
37 0 – 255 0 – 100 10 pix Blue intensity
38 0 – 255 0 – 100 11 pix Red intensity
39 0 – 255 0 – 100 11 pix Green intensity
40 0 – 255 0 – 100 11 pix Blue intensity
41 0 – 255 0 – 100 12 pix Red intensity
42 0 – 255 0 – 100 12 pix Green intensity
43 0 – 255 0 – 100 12 pix Blue intensity
0 – 255 0 – 100 Red Strobe Intensity
2 0 – 255 0 – 100 Green Strobe Intensity
3 0 – 255 0 – 100 Blue Strobe Intensity
4 0 – 255 0 – 100 White Strobe Intensity
5 0 – 255 0 – 100 Strobe Intensity
6 0 – 255 0 – 100 Strobe Duration
7 0 – 255 0 – 100 Strobe Rate
8 0 – 255 0 – 100 Strobe FX
9 0 – 255 0 – 100 1 pix Red intensity
10 0 – 255 0 – 100 1 pix Green intensity
11 0 – 255 0 – 100 1 pix Blue intensity
12 0 – 255 0 – 100 1 pix White intensity
0 – 255 0 – 100 2 pix Red intensity
14 0 – 255 0 – 100 2 pix Green intensity
15 0 – 255 0 – 100 2 pix Blue intensity
16 0 – 255 0 – 100 2 pix White intensity
0 – 255 0 – 100 3 pix Red intensity
18 0 – 255 0 – 100 3 pix Green intensity
19 0 – 255 0 – 100 3 pix Blue intensity
20 0 – 255 0 – 100 3 pix White intensity
0 – 255 0 – 100 4 pix Red intensity
22 0 – 255 0 – 100 4 pix Green intensity
23 0 – 255 0 – 100 4 pix Blue intensity
24 0 – 255 0 – 100 4 pix White intensity
0 – 255 0 – 100 5 pix Red intensity
26 0 – 255 0 – 100 5 pix Green intensity
27 0 – 255 0 – 100 5 pix Blue intensity
28 0 – 255 0 – 100 5 pix White intensity
29 0 – 255 0 – 100 6 pix Red intensity
30 0 – 255 0 – 100 6 pix Green intensity
31 0 – 255 0 – 100 6 pix Blue intensity
32 0 – 255 0 – 100 6 pix White intensity
0 – 255 0 – 100 7 pix Red intensity
34 0 – 255 0 – 100 7 pix Green intensity
35 0 – 255 0 – 100 7 pix Blue intensity
36 0 – 255 0 – 100 7 pix White intensity
37 0 – 255 0 – 100 8 pix Red intensity
38 0 – 255 0 – 100 8 pix Green intensity
39 0 – 255 0 – 100 8 pix Blue intensity
40 0 – 255 0 – 100 8 pix White intensity
41 0 – 255 0 – 100 9 pix Red intensity
42 0 – 255 0 – 100 9 pix Green intensity
43 0 – 255 0 – 100 9 pix Blue intensity
44 0 – 255 0 – 100 9 pix White intensity
45 0 – 255 0 – 100 10 pix Red intensity
46 0 – 255 0 – 100 10 pix Green intensity
47 0 – 255 0 – 100 10 pix Blue intensity
48 0 – 255 0 – 100 10 pix White intensity
49 0 – 255 0 – 100 11 pix Red intensity
50 0 – 255 0 – 100 11 pix Green intensity
51 0 – 255 0 – 100 11 pix Blue intensity
52 0 – 255 0 – 100 11 pix White intensity
53 0 – 255 0 – 100 12 pix Red intensity
54 0 – 255 0 – 100 12 pix Green intensity
55 0 – 255 0 – 100 12 pix Blue intensity
56 0 – 255 0 – 100 12 pix White intensity

RDM SENSORS AND FUNCTIONS

Solaris Flare Q+ LR can be operated via Remote Device Management (RDM) that will assist with fixture setup and maintenance.

PID Name

Category – Status Collection
0x0020| QUEUED_MESSAGE
Category – RDM Information
0x0050| SUPPORTED_PARAMETERS
0x0051| PARAMETER_DESCRIPTION
Category – Product Information
0x0060| DEVICE_INFO
0x0080| DEVICE_MODEL_DESCRIPTION
0x0081| MANUFACTURER_LABEL
0x0082| DEVICE_LABEL
0x0090| FACTORY_DEFAULTS
0x00C0| SOFTWARE_VERSION_LABEL
Category – DMX512 Setup
0x00E0| DMX_PERSONALITY
 | DMX_PERSONALITY_DESCRIPTION
0x00F0| DMX_START_ADDRESS
Category – Sensors
0x0200| SENSOR_DEFINITION
0x0201| SENSOR_VALUE
0x0202| RECORD_SENSORS
Category – Control
0x1000| IDENTIFY_DEVICE
0x1001| RESET_DEVICE

LIMITED WARRANTY

Solaris fixtures are warranted by TMB against defective materials or workmanship for a period of two (2) years from the date of original sale by TMB.

TMB’s warranty shall be restricted to the repair or replacement of any part that proves to be defective and for which a claim is submitted to TMB before the expiration of the applicable warranty periods.

This Limited Warranty is void if the defects of the Product are the result of:

  • Opening the casing, repair, or adjustment by anyone other than TMB or persons specifically authorized by TMB
  • Accident, physical abuse, mishandling, or misapplication of the product.
  • Damage due to lightning, earthquake, flood, terrorism, war, or act of God.

TMB will not assume responsibility for any labor expended, or materials used, to replace and/or repair the Product without TMB’s prior written authorization. Any repair of the Product in the field, and any associated labor charges, must be authorized in advance by TMB. Freight costs on warranty repairs are split 50/50: Customer pays to ship defective product to TMB; TMB pays to ship repaired product, ground freight, back to Customer.

This warranty does not cover consequential damages or costs of any kind.

A Return Merchandise Authorization (RMA) Number must be obtained from TMB prior to return of any defective merchandise for warranty or non-warranty repair. For all repairs please contact TMB Tech Support Repair using the contact information below or email TechSupportRepairNA@tmb.com.

US

527 Park Ave
San Fernando, CA 91340
Tel: +1 818.899.8818
Fax: +1 818.899.8813
tmb-info@tmb.com
www.tmb.com

UK

21 Armstrong Way
Southall, UB2 4SD England
Tel: +44 (0)20.8574.9700
Fax: +44 (0)20.8574.9701
tmb-info@tmb.com
www.tmb.com

Solaris Flare LR Q+ Quick Start Guide
Solaris-Flare-LRQ+QSG-v1.0
Effective 14 April 2021

© Copyright 2021, TMB

All rights reserved

TMB authorizes its customers to download and print this electronically published Quick Start Guide for professional use only.

TMB prohibits reproduction, modification or distribution of this document for any other purposes, without express written consent.

Specifications are subject to change without notice. The information in this document supersedes all previously supplied information before the effective date listed above. TMB has confidence in the accuracy of the document information herein but assumes no responsibility or liability for any loss occurring as a direct or indirect result of errors or exclusions whether by accident or any other cause.

CONTACT INFORMATION

LOS ANGELES HEADQUARTERS
527 Park Avenue | San Fernando, CA 91340, USA
Tel: +1 818.899.8818 | Fax: +1 818.899.8813
sales@tmb.com

TMB 24/7 TECH SUPPORT
US/Canada: +1.818.794.1286
Toll Free: 1.877.862.3833 (1.877.TMB.DUDE)
UK: +44 (0)20.8574.9739
Toll Free: 0800.652.5418
techsupport@tmb.com

LOS ANGELES +1 818.899.8818
LONDON +44 (0)20.8574.9700
NEW YORK +1 201.896.8600
BEIJING +86 10.8492.1587
CANADA +1 519.538.0888

tmb logo

A full service company providing technical support, customer service, and follow-up. Providing products and services for the industrial, entertainment, installation, defense, broadcast, research, telecommunications, and signage industries. Servicing the global market from offices in Los Angeles, London, New York, Toronto, and Beijing.

SOLARIS logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals