Shenzhen Ariza Electronic F02 Door Alarm Instruction Manual

June 6, 2024
Shenzhen Ariza Electronic

Shenzhen - logo Ariza Electronic F02 Door Alarm
Instruction Manual
Shenzhen Ariza Electronic F02 Door
Alarm

Specification

Network: 2.4GHz Induction distance:0–35mm
Working voltage: 3V Decibel : >80d8 (F02)
Battery: 2AAA batteries Low battery remind: 2.3V±0.2V
Standby current: < 10uA Alarm Size: 575716mm
Working humidity: 85% ice-free Magnet Size: 571516mm
Storage temperature: 0C- 50 G.W.:118g

How to use

  1. Model: FO2 with alarm 1–network button ®set button.
  2. Remove the insulation sheet on the back of the alarm.
  3. Separate alarm from magnet to test.
  4. Press the SET button to choose a different sound press and hold the SET button for 3 seconds to choose the volume level 3 difference volume level.
  5. Press and hold the distribution button for 3 seconds to enter the distribution state.

Shenzhen Ariza Electronic F02 Door Alarm - use

Installation

  1. Put the double-sided adhesive tape on the back of the alarm
  2. Mount alarm and magnet on to window or door with the distance <15mm apart
  3. Wipe the dust and other particles clean with a cleaning sprayer before installation.

Shenzhen Ariza Electronic F02 Door Alarm -
Installation

Download App

  1. ISO iphone: Download Smart Life” from Google’lay
  2. Android Download “Smart Life” from the app store.
  3. Open the Smart Life app and create a new account
  4. Register and log in.

https://smartapp.tuya.com/smartlifeShenzhen Ariza Electronic F02 Door
Alarm - register

Connection instruction

Make sure your smartphone connects to the WIFE and opens GPS positioning. Only 2.4g WIFI is supported.

Contact Sensor(WiFi)

  1. Click Add device to connect the door alarm at your first use or Click + in the upper night to add device
  2. In the manual interface select contact sensor(WFi)” in the list of security & Sensors” and go to the next step
  3. Press and hold the network button for 3-5 seconds the LED green light is flashing quickly.
  4. Click Confirm indicator flash’ to enter WIF1 name and password and then confirm connection.
  5. After the connection is completed .click “complete” on the application interface of the mobile phone. and the successful connection will enter the device interface.

Shenzhen Ariza Electronic F02 Door Alarm - Contact
Sensor\(WiFi\)

Linkage Instruction

1. Open the Smart Life app and click Smart’ at the bottom of the interface to enter the setting interface.
2. Click + in the upper night, the first step selects the automation condition, and the second step set the task.

Shenzhen Ariza Electronic F02 Door Alarm - Linkage
Instruction

Notification setting

  1. Select “me in the lower night of the Smart Life app to enter the account Setting interface
  2. Click Setting’ and select Sound’.
  3. Click “App Notification’ to open the Push message Setting
  4. Mobile Application Management, smart life app *Notification Management” open Allow notification”

Sharing equipment

  1. You can share the smart door alarm with your family and they will receive the message of alarm.
  2. Select the device on the Smart Life app and Click in the upper night of the device interface to enter the door alarm interface.
  3. Select Share Device click Add Share to enter the Shared account and then press Complete’

Create groups

  1. You can create a group for all smart door alarms. it is easy for you to control them simultaneously.
  2. Select the device in the Smart Life app and click ” L. in the upper right of the device interface to enter the door alarm interface.
  3. Select “Create Group” in the screen interface, select what you choose from the list, and then press ‘Save-.

Replace battery

when it is necessary to replace the battery in order to get the best battery life please replace the two AAA batteries together The replacement doesn’t delete the door alarm Settings.

Low Battery indicator

  1. When the battery voltage is lower than 2.3V±0 .2V. the device will send a notification to the user’s mobile phone through WIFI.
  2. When the battery power is too low. the new MA battery should be replaced in time.

Battery Notices

  1. Use a properly sized AAA battery.
  2. Install the battery in the correct polarity Incorrect polarity may damage the alarm.
  3. Do not mix different types of batteries, such as alkaline carbon old and new batteries
  4. Don’t try to charge non-rechargeable batteries
  5. Disassembled the battery .put the battery into the fire and threw battery into the water are not allowed.
    Old batteries must be disposed of in accordance with local waste recovery regulations

FAQ

  1. Connection application failed?
    a. Make sure that you are connected to a 2.4ghz WF network. This device does not support a 5GHz WFi network
    b. Make sure to connect when the battery is fully charged.

  2. No bell when the door was opened?
    Make sure whether the volume of the alarm at the lowest volume or in mute mode

  3. No message when opening the door?
    Make sure that the alarm in the WIF] normal transceiver range.

  4. No response when opening the door no message ring indicator light is not on?
    a. Make sure that the door alarm and magnet are installed correctly.
    b. Door alarm was interference by magnetic material and iron can be replaced by the position of installation.

  5. When installing the battery the door alarm no sound?
    Make sure the battery is properly installed and whether the battery polarity is reversed

  6. The LED light of the door alarm is flashing all the time?
    This is a low battery indicator, please replace the batteries

Warranty Card

Thank you for purchasing our product.
Please fill in the details below and keep them safe.

User name:|
---|---
Contact:|
Model name:|
Contact add:|
Purchase add:|
Purchase date:|

Certificate:

Shenzhen Ariza Electronic F02 Door Alarm - Warranty
Card

FCC Caution:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (I) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device. pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions. may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception. which can be determined by turning the equipment off and on. the user is encouraged to try to correct the interference by one or more of the

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 21km between the radiator & your body.