Specifications

  • Physical: Length: 180 mm [7.1 inch], Width: 91 mm [3.6 inch], Height: 67 mm [2.6 inch], Weight: TBA, Color: Black, Enclosure: Impact-resistant polycarbonate, Mounting: Surface with 4 x M4 screws
  • Connections:
    • DMX/RDM: Yes
    • Power In: Yes
    • UrbanLux Output : No
  • Control: DMX, RDM, Art-Net, sACN
  • Addressing: Via RDM, Via DMX link
  • Firmware update: No
  • Electrical:
    • Voltage Input: 100VAC to 277VAV (50/60 Hz)
    • Power consumption: 1300W max @ 100VAC, 1560W max @ 120VAC, 3120W max @ 240VAC, 3600W max @ 277VAC
    • Inrush current : TBA
    • Fuse: TBA
  • Environment:
    • Operating temperature: TBA
    • Protection rating : TBA

Product Usage Instructions

Dimensions and Mounting Information
Fasten the unit to a well-ventilated area using four M4 screws through the molded-on flanges. Torque the screws within the range of 2.2 Nm to 2.8 Nm.

Mounting on DIN Rail
In case of installation on a DIN rail, ensure the use of the provided DIN mounting plate. Secure the unit to the mounting plate using four M4 screws through the molded-on flanges. Torque specification for these screws is between 2.2 Nm and 2.8 Nm. Ensure proper ventilation if mounted in a closed- type installation box.

Wiring Information

  • Connecting Power
    When connecting to LINE, use a circuit breaker or fuse rated at 13A MAX. Connect LINE L and EARTH NEUTRAL N as specified. Do not exceed the allowed amount of UrbanLux fixtures per DOP Injector Output.

  • Connecting DMX
    The DOP Injector has two 3-pin PTB sockets with removable plugs for DMX/RDM input and output. Follow the DMX pinout instructions provided in the manual for proper connection.

FAQ

  • Can this product be used outdoors?
    No, this product is designed for indoor use only.

  • What is the maximum power consumption of the product?
    The maximum power consumption varies based on the input voltage, with a maximum of 3600W at 277VAC.

Safety Information

  • Read the following installation instructions carefully before installing, powering, or operating the device.

  • WARNING!
    THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED

  • ATTENTION!
    CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS

  • FOR INDOOR USE ONLY!

Dimensions and mounting information

SOLARIS-UrbanLux-DoP-Injector-fig-2

Fasten the unit to a well-ventilated area using four M4 screws through the molded-on flanges. Torque the screws within the range of 2.2 Nm to 2.8 Nm.

Mounting on DIN Rail

  • In case of installation on a DIN rail, ensure the use of the provided DIN mounting plate.
  • The unit should be secured to a mounting plate using four M4 screws through the molded-on flanges. The torque specification for these screws is between 2.2 Nm and 2.8 Nm.
  • Please ensure proper ventilation if mounted in a closed-type installation box.

SOLARIS-UrbanLux-DoP-Injector-fig-3

Wiring information

Connecting Power

  • WARNING! For protection from electric shock, the fixture must be electrically connected to ground (earth). The AC mains power supply must be fitted with a fuse or circuit breaker of 13A MAX and ground-fault (earth-fault) protection.

  • WARNING! DOP Injector require UrbanLux luminaires to operate.
    DOP Injector must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations

  • DANGER!

    • Risk of electric shock. Do not open the device.
    • Always power off the fixture before mounting/removing accessories or dismantling the product.
    • Ensure that the mains power is cut off when wiring the device or connecting to a luminaire.
    • Ensure that the device is electrically connected to earth (ground).
    • Do not apply power if the device or cables are damaged.
    • Do not immerse the fixture in water or liquid.

Connecting Power

Connecting to LINE use Circuit Breaker or Fuse rated at 13A MAX !

SOLARIS-UrbanLux-DoP-Injector-fig-4

Never exceed allowed amount of UrbanLux fixtures per DOP Injector Output

SOLARIS-UrbanLux-DoP-Injector-fig-5

Connecting DMX

  • DOP Injector has two 3-pin PTB sockets with removable plugs for DMX/RDM input and output.

  • DMX pinout:

  • Connect DMX data output from the controller to the DOP Injector DMX In PTB plug using screws.

  • Run the data link from the DOP Injector DMX Thru socket to the DMX In of the next unit.

  • Terminate data link by connecting a 120 Ohm resistor between +Data and -Data at the DMX Thru of the last unit in DMX line.

SOLARIS-UrbanLux-DoP-Injector-fig-7

Technical Specs

Physical|
---|---
Length| 180 mm [7.1 inch]
Width| 91 mm [3.6 inch]
Height| 67 mm [2.6 inch]
Weight| TBA
Color| black
Enclosure| Impact-resistant polycarbonate
Mounting| to surface with 4 x M4 screws
 |
Connections|
DMX/RDM| PTB pluggable terminal block

(30 to 14AWG)

Power In| screwdriver-actuated CAGE CLAMP® connection

(28 to 12AWG)

UrbanLux Output| screwdriver-actuated CAGE CLAMP® connection

(28 to 12AWG)

 |
Control|
DMX| Yes
RDM| Yes
Art- Net| No
sACN| No
Addressing| via RDM
Firmware update| via DMX link
 |
Electrical|
Voltage Input| 100VAC to 277VAV ( 50 / 60 Hz )
Power consumption| 1300W max @ 100VAC

1560W max @ 120VAC

3120W max @ 240VAC

3600W max @ 277VAC

Inrush current| <40A
Fuse| external 13A max (not provided)
 |
Environment|
Operating temperature| -25°C to 50°C [-4°F to +122°F]
Protection rating| IP30