HOLLYLAND DB25 Wireless Tally System User Manual

June 1, 2024
HOLLYLAND

HOLLYLAND DB25 Wireless Tally System

Specifications

  • Model: Wireless Tally System
  • Version: V1.0
  • Compatibility: Refer to Compatibility List

Safety Precautions

It is important to follow these safety precautions while using the Wireless Tally System:

  • Ensure proper ventilation to prevent overheating.
  • Avoid exposure to moisture or liquids.
  • Do not disassemble the device; contact authorized service
    personnel for any repairs.

Overview
The Tally Box features various components including USB port, display screen, control keys, power button, and antenna connectors.

Interface
The interface includes indicators for RJ45 port connection status and different Tally light statuses (Normal, PGM, PVW).

Installing the Tally Box

  1. Install the antennas as shown in the diagram provided.
  2. Connect the power adapter to the Tally Box.
  3. Press the power button to turn on the Tally Box.

Operations

The Tally Box allows for learning the sequence of connections and selecting the corresponding ports based on supported Tally ports on the switcher.
Note: Each number can only match one PGM button.

Overview
The Tally Light provides visual cues with different colors to indicate various statuses.

Installing the Tally Light
To install the Tally Light, follow the instructions provided in the manual and ensure proper pairing and upgrading procedures are followed.

Operations

  • Understand the different Tally Light colors and their= meanings.
  • Pair the Tally Light with the corresponding Tally Box.
  • Upgrade the Tally Light firmware when necessary.

FAQ
Q: How do I pair the Tally Light with the Tally Box?
A: To pair the Tally Light, make sure both devices are powered on and follow the pairing instructions provided in the user manual. Typically, it involves a simple synchronization process.

Safety Precautions

For your safety, please read the following safety precautions before using the product to ensure its correct use:

  • Do not place the device near or inside heating devices (including but not limited to microwave ovens, induction cookers, electric ovens, electric heaters, pressure cookers, water heaters, and gas stoves) to prevent the battery from overheating and exploding.
  • Use the original charger and data cables.
  • Using unauthorized or incompatible chargers, data cables, or batteries may cause electric shock, fire, explosion, or other dangers.
  • Avoid stepping on or squeezing the power cable, especially at the plugs, outlets, and points where it extends from the device.
  • Unplug the product during thunderstorms or when it is not in use for an extended period.
  • Do not disassemble the device unless you are a qualified technician from Hollyland or under professional guidance.
  • All repair work should be done by qualified technicians from the manufacturer.

Tally Box Introduction

Overview

HOLLYLAND-DB25-Wireless-Tally-System- \(2\)

  1. USB Port
  2. Display Screen
  3. Left Key
  4. Up Key
  5. Right Key
  6. Down Key
  7. Menu/Confirm Button (long press to enter the menu/press to confirm) Power
  8.  Button (red: off; green: on)
  9. Antenna Connector
  10. DC Input
  11. Tally Input RJ45 Port
  12. Switcher Loopout RJ45 Port
  13. Tally Input Port (DB25 F)
  14. USB-C Port (reserved)
  15. Antenna Connector

Interface

  1. RJ45 Port Connection Status
  2. Tally Light Normal Status
  3. Tally Light PGM Status
  4. Tally Light PVW Status

Installing the Tally Box

HOLLYLAND-DB25-Wireless-Tally-System- \(4\)

  1. Install the antennas as shown in the diagram. HOLLYLAND-DB25-Wireless-Tally-System- \(5\)
  2. Connect the power adapter.
  3. Press the power button to turn the Tally box on.

Operations
Learning the Sequence

  1. Preparing the devices

    • Confirm the supported Tally port on the switcher.HOLLYLAND-DB25-Wireless-Tally-System- \(6\)
    • Connect the Tally box and switcher using the corresponding cable. HOLLYLAND-DB25-Wireless-Tally-System- \(7\) HOLLYLAND-DB25-Wireless-Tally-System- \(8\)
    • Power on the Tally box, Tally light, and switcher.
    • Press any PGM and PVW buttons except for 1, for example, PGM 2 and PVW 3.
  2. Learning the PGM and PVW sequence

    • Long press the menu button to enter the menu, choose the Sequence Learning function, and select the corresponding port based on the supported Tally port on the switcher.

    • Press any PGM button except PGM1 within 10 seconds to enter the PGM sequence learning interface.

    • Note that if there are no valid operations within 10 seconds, the interface will display “The switcher does not support Sequence Learning”. In case of a timeout, repeat the previous steps.

    • After entering the PGM sequence learning interface, press the corresponding PGM button on the switcher that matches the number blinking on the learning interface. For example, if number 1 is blinking, press PGM1 on the switcher. After the first learning, the blinking number will sequentially switch to the next. For example, after the learning of PGM1, number 2 will start blinking. Continue with learning one by one.
      Note: One number can only match one PGM button.

    • After the PGM sequence learning is completed, the Tally box will display the PVW sequence learning interface. Press any PVW button except PVW1 within 10 seconds to enter the PVW sequence learning interface.

    • After entering the PVW sequence learning interface, refer to the PGM sequence learning steps to complete the PVW sequence learning.

    • If a key conflict is detected in the PVW sequence learning process, the Tally box will display ”Please press PGM1 to avoid key conflicts”. Follow the instruction to continue with the sequence learning.

    • Continue with the sequence learning until ”Sequence Learning Completed” is displayed.

Switcher IP Address

  1. Preparing the devices
    • Connect the Tally box and switcher using an Ethernet cable.
    • Power on the Tally box, Tally light, and switcher.
  2. Configuring the IP address
    • Long press the menu button to enter the menu, and choose Switcher IP Address.
  • Set the IP address, subnet mask, and gateway to the same as the switcher. HOLLYLAND-DB25-Wireless-Tally-System- \(18\)
  • Click Yes.

Adjusting the Brightness

  • Long press the menu button to enter the menu, and choose Brightness Control.
  • Four levels are available to adjust the brightness of all Tally lights.

Note: Brightness adjustment on the side of the Tally light will not affect brightness settings on the  side of the Tally box.

Device IP Address

  • Long press the menu button to enter the menu, choose Settings, and then select Device IP Address.
  • The Tally box supports manual configuration of the IP address, subnet mask, and gateway.

Note: When configuring the IP address through Switcher IP Address, the IP of the Tally box will  automatically change to the same as the switcher.

Upgrading the Tally Box

  • Download the firmware upgrade program and new firmware to your computer, and then open the program.
  • Connect the box and computer through a USB-A to USB-C cable. Wait for the firmware upgrade program to detect the connection.HOLLYLAND-DB25-Wireless-Tally-System- \(24\)
  • Click Yes to start the upgrade process. Do not turn off the Tally box or unplug the cable during the process to avoid upgrade failures.
  • After the upgrade process is completed, the program and box will display ”Tally Upgrade Successful”, and then you can unplug the cable.

Note: The firmware installation file for the Tally box can be obtained from Hollyland’s technical support  or official website.

OverviewHOLLYLAND-DB25-Wireless-Tally-System-
\(27\)

  1. USB-C Port (for charging, upgrading and pairing)
  2. Battery Level LED
  3. Tally Light Number Control Dial
  4. Power Button (press and hold for 3s to power on/off; double press after startup to adjust Tally light brightness)
  5. Battery Compartment Switch
  6. Back Clip

Installing the Tally LightHOLLYLAND-DB25-Wireless-Tally-System-
\(28\)

  1. Install the battery. HOLLYLAND-DB25-Wireless-Tally-System- \(29\)
  2. Install the Tally light on the shooting device as shown in the diagram. HOLLYLAND-DB25-Wireless-Tally-System- \(30\)
  3. Press the power button for 3 seconds to turn on the Tally light.

Operations
Tally Light Colors HOLLYLAND-DB25-Wireless-Tally-System-
\(31\)

Pairing the Tally Light

  • Use a USB-C to USB-A cable to connect the Tally light to the Tally box. HOLLYLAND-DB25-Wireless-Tally-System- \(32\)
  • Wait for the Tally box to display the pairing interface,  and then click Yes. HOLLYLAND-DB25-Wireless-Tally-System- \(33\)

Note: After pairing, you still need to manually select the number by rotating the number control dial.

Upgrading the Tally Light

  • Use a USB-C to USB-A cable to connect the Tally light to the Tally box. Wait for the Tally box to display the upgrade interface.
  • Click Yes to start the upgrade process. Do not turn off the Tally box or Tally light or unplug the USB cable during the process to avoid upgrade failures.
  • During the upgrade process, the Tally light will flash green fast until the upgrade is completed.
  • After the upgrade process is completed, the Tally box will display ”Tally Upgrade Successful”, and the Tally light will return to its former working state after a solid green light for 3 seconds.

Note: Before upgrading the Tally light, ensure the Tally box has been upgraded.

Compatibility List

Brand Model Cable No.

Datavideo

| SE2800| DB25 Male to DB25 Male|
HS1200| DB25 Male to HDB15 Female|

Panasonic

| AV-HS6000MC| DB25 Male to DB25 Male|
AV-HS410MC| DB25 Male to Dual DB15 Male|
Sony| MCX-500| DB25 Male to DB9 Female|
BMD| ATEM Mini Pro| Ethernet Cable|
ATEM Mini Extreme ISO| Ethernet Cable|
ATEM 1 M/E Constellation HD| Ethernet Cable|
ATEM Television Studio Pro 4K| Ethernet Cable|
ATEM 1 M/E Production Studio 8K| Ethernet Cable|
Roland| Roland V-60HD| DB25 Male to DB25 Male|
Roland V-600UHD| DB25 Male to DB25 Male|
Roland V-800HD| DB25 Male to Dual HDB15 Male|
Roland V-1200HD| DB25 Male to DB25 Male|
vMix| vMix| Ethernet Cable|
DeviceWell| DeviceWell HDS7305| DB25 Male to HDB15 Male|

Cable

  1. CAT5 Cable
  2. Tally Cable (DB25 Male to DB25 Male)
  3. Tally Cable (DB25 Male to DB9 Female)
  4. Tally Cable (DB25 Male to HDB15 Male)
  5. Tally Cable (DB25 Male to HDB15 Female)
  6. Tally Cable (DB25 Male to Dual DB15 Male)
  7. Tally Cable (DB25 Male to Dual HDB15 Male)

Specifications

| Tally Light| Tally Box
---|---|---
LOS Range| 2,625ft (800m)
Operaing Frequency| 2.4 GHz
Modulation Mode| LORA
Receiver Sensitivity| < -115 dBm
Latency| < 150ms
Battery Life| > 8 hours
Dimensions

(L × W × H)

| 77.8 × 50.5 × 37.4mm| 142.5 × 232.8 × 50.1mm
Weight| ≈ 85g| ≈ 1,262g
**** Temperature| Working: 32℉ to 113℉ (0℃ to 45℃ ) Storage: 14℉ to 140℉ (-10℃ to 60℃ )

Disclaimer

Support
If you encounter any problems in using the product or need any help, please contact the Hollyland Support Team via the following ways

HOLLYLAND-DB25-Wireless-Tally-System- \(1\)

[email protected]
www.hollyland.com

Statement
All copyrights belong to Shenzhen Hollyland Technology Co., Ltd. Without the written approval of Shenzhen Hollyland Technology Co., Ltd., no organization or individual may copy or reproduce part or all of any written or illustrative content and disseminate it in any form.

Trademark Statement
All the trademarks are owned by Shenzhen Hollyland Technology Co., Ltd.

Note
Due to product version upgrades or other reasons, this User Manual will be updated from time to time. Unless otherwise agreed, this document is provided as a guide for use only. All representations, information, and recommendations in this document do not constitute warranties of any kind, express or implied.
Manufacturer:   Shenzhen Hollyland Technology Co., Ltd.
Address:  8F, 5D Building, Skyworth Innovation Valley, Tangtou Road, Shiyan Street, Baoan District, Shenzhen, 518108, China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HOLLYLAND User Manuals

Related Manuals